Schimb de cldur n regim staionar.Determinarea coeficienilor globali de transfer termic in schimbtoare de cldur tubulare (eav n eav)
Gm1 (kg/s)Gm2 (kg/s)t2 (int rece)Ct2 Ct2 Ct2 Ct2 Ct2 Ct2 (ies rece)Ct1 (int c)Ct1 (ies c) C
0.005830.0036791115151923244124
0.009720.003679.51316172125.526.54224
0.01380.003671013.51718222727.54324
d t med (C)k exp ck exp rQ caldDtw (m/s)
15.97914492519.1459288.3562414.775432.50.051575
14.9944428976.6386348.2652732.2076330.085987
14.737279361489.158364.76421097.30733.50.122081
ReNualfa 1Q recewdtReNualfa2k teor
810.1585.551287.745115.1920.0026515102.629511.286158.70296.596
1364.4576.814353.644130.55117103.042
1956.5697.842407.537134.39117.5107.171
A=0.05
D ech112
Dech242
S0.00011
s20.00138474
m
-0.024122575
-0.040525425
-0.0477935
tM1 CA [m2]dtm1 Ct1 CtM2 Cdtm2 Ct2 CtM3 Cdtm3 Ct3 C
170.04998719.099798728.09979915.519.0983117328.5983115.520.0225530.02255
180.04510919.994774930.99477516.519.9204806932.920481620.1584633.65846
220.03994524.145791539.1457922124.8124143940.812412125.7673842.76738
260.03633128.296664843.2966652529.0961075646.096112530.1128748.11287
260.02855927.788881746.7888822629.2935406850.293542630.0952552.09525
300.02114531.514980654.5149812931.6773957457.177429.532.8742259.87422
321.55E-0233.176748157.17674832.534.673388661.173393335.7265563.22655