Lungimi de stuturi la conducte izolate si neizolate Petrom OMV Norm H 1203 Connection Lengths On Insulated and Non-Insulated Pipelines Petrom OMV Standard H 1203 Elaborat/ Compiled: Nechifor Daniela Verificat/ Checked: Decusara Felicia Rev: 2/15.01.2009 Aprobat/ Approved: Neil Morgan Divizia Rafinare Petrom OMV isi rezerva toate drepturile asupra acestei documentatii si va da in judecata pe orice persoana neautorizata sa o utilizeze sau sa o transmita la terti Petrom OMV Refining Division reserves all its rights to these documents and will take legal action against anyone using them or passing them on without authorization. Aceasta norma a fost elaborata pentru rafinariile Petrom prin prelucrarea si adaptarea Normei OMV H 1203 revizie 01.09.2008 This norm was elaborated for Petrom refineries by the processing and adapting of norm OMV H 1203 revision 01.09.2008 Capitol Cuprins Nr. Pag. Point Content Page 1.0 Generalitati 2 1.0 General 2 1.1 Domeniu de valabilitate 2 1.1 Scope 2 1.2 Norme si prescriptii 2 1.2 Standards and instructions 2 2.0 Executie 3 2.0 Implementation 3 2.1 Lungimi de stuturi pentru conducte izolate 3 2.1 Connection lengths for insulated pipelines 3 2.2 Lungimi de stuturi pentru conducte neizolate 4 2.2 Connection lengths for non-insulated pipelines 4 2.3 Lungimi pentru stuturi care sunt izolate impreuna 5 2.3 Connection lengths for connections that are also insulated 5 Anexa 1 Norme si prescriptii 6 Annex 1 Standards and regulations 6

description

H-1203

Transcript of Petrom OMV_Norm_H_1203_rom_eng_rev.2_2009-01-15

Page 1: Petrom OMV_Norm_H_1203_rom_eng_rev.2_2009-01-15

Lungimi de stuturi la conducte izolate si neizolate

Petrom OMV Norm

H 1203

Connection Lengths On Insulated and Non-Insulated Pipelines

Petrom OMV Standard

H 1203

Elaborat/ Compiled:

Nechifor Daniela

Verificat/ Checked:

Decusara Felicia

Rev: 2/15.01.2009

Aprobat/ Approved:

Neil Morgan

Divizia Rafinare Petrom OMV isi rezerva toate drepturile asupra acestei documentatii si va da in judecata pe orice persoana neautorizata sa o utilizeze sau sa o transmita la terti

Petrom OMV Refining Division reserves all its rights to these documents and will take legal action against anyone using them or passing them on without authorization.

Aceasta norma a fost elaborata pentru rafinariile Petrom prin prelucrarea si adaptarea Normei OMV H 1203 revizie 01.09.2008

This norm was elaborated for Petrom refineries by the processing and adapting of norm OMV H 1203 revision 01.09.2008

Capitol Cuprins Nr. Pag. Point Content Page

1.0 Generalitati 2 1.0 General 2 1.1 Domeniu de valabilitate 2 1.1 Scope 2 1.2 Norme si prescriptii 2 1.2 Standards and

instructions 2

2.0 Executie 3 2.0 Implementation 3 2.1 Lungimi de stuturi pentru

conducte izolate 3 2.1 Connection lengths for

insulated pipelines 3

2.2 Lungimi de stuturi pentru conducte neizolate

4 2.2 Connection lengths for non-insulated pipelines

4

2.3 Lungimi pentru stuturi care sunt izolate impreuna

5 2.3 Connection lengths for connections that are also insulated

5

Anexa 1 Norme si prescriptii 6 Annex 1 Standards and regulations

6

Page 2: Petrom OMV_Norm_H_1203_rom_eng_rev.2_2009-01-15

Pag 2 Norma Petrom OMV H 1203 / Petrom OMV Standard H 1203

1.0 GENERALITATI 1.0 GENERAL

1.1 Domeniul de valabilitate 1.1 Scope

Aceasta norma este valabila in cadrul OMV Petrom pentru lungimile stuturilor la conducte izolate si neizolate. Prezenta norma poate fi aplicata si pentru alte locatii. Denumirile functiilor care au fost utilizate in prezenta norma se vor intelege neutre din punct de vedere al genului.

This standard applies within OMV Petrom for connection lengths on insulated and non-insulated pipelines. This Standard can also be applied for other location departments. The functional descriptions in this standard are to be regarded as gender-neutral.

1.2 Norme si prescriptii 1.2 Standards and instructions

In coroborare cu prezenta norma se vor respecta dispozitiile, normele si directivele valabile in Romania, in varianta lor aflata in vigoare, care sunt mentionate la Anexa. Nu consideram enumerarea noastra ca fiind una completa

Daca intre diferitele dispozitii, reglementari, norme si directive apar diferente sau contradictii, iar aspectele respective nu sunt in mod expres clarificate prin prezenta norma, se va aplica reglementarea cu formularea cea mai restrictiva. In cazul in care prevederile se exclud reciproc, atunci se va aplica reglementarea prevazuta de legislatia romaneasca.

Intra in responsabilitatea executantului sa verifice daca prevederile prezentei norme sunt adecvate scopului lucrarii respective. Aplicarea normei nu il exonereaza pe executant de raspunderea pe care o are in calitate de antreprenor profesionist si responsabil. Daca executantul are obiectii cu privire la una dintre prevederile stabilite, el il va informa imediat in scris pe angajator despre acest lucru. Este obligatia contractorului sa observe reglementarile in vigoare si sa se asigure ca subcontractorii sai procedeaza la fel.

In conjunction with this Standard, the respective specifications, standards and directives legally applicable in Romania and stated in the Annex should be taken into account in their currently valid form. This listing is not claimed to be complete.

In the event of deviations or conflicts arising between the various specifications, standards and directives and there is no firm definition by this standard, then the strictest formulation is to be applied in each case. Where they are mutually exclusive, then the Romanian statutory regulations will apply. The contractor will be responsible for checking the appropriateness of this standard for the intended purpose. The application does not relieve the contractor of his responsibility as specialist and independent entrepreneur. If the contractor has reservations concerning an agreed definition, then he must notify the client of this in writing without delay. It is the duty of the contractor to observe the valid regulations and to ensure that his subcontractors also observe them.

Page 3: Petrom OMV_Norm_H_1203_rom_eng_rev.2_2009-01-15

Pag 3 Norma Petrom OMV H 1203 / Petrom OMV Standard H 1203

2.0 EXECUTIE 2.0 IMPLEMENTATION

Lungimile stuturilor se dimensioneaza pentru capetele flanselor si ale mufelor.

In cazul conductelor izolate, stuturile cu capetele flanselor trebuie sa iasa minim 150 mm din izolatie, iar cele cu capetele mufelor- minim 40 mm. In cazul conductelor neizolate, stuturile trebuie sa aiba lungimea minima 150 mm.

Daca stuturile se izoleaza în comun, este valabila urmatoarea reglementare: Stuturile cu capete de flanse trebuie sa iasa din izolatia conductei principale minim 150 mm, iar cele cu capete de mufe – minim 40 mm (vezi pct. 2.3). In cazul unor straturi de izolare cu grosime mai mare decât cele din tabelele urmatoare, lungimile minime ale stuturilor se vor calcula.

The connection lengths are designed for flange and coupling ends.

For insulated pipelines, the connections with flange ends must protrude at least 150 mm from the insulation and for coupling ends at least 40 mm. For non-insulated pipelines, the connections with flange and coupling ends must be at least 150 mm long. If connections are also insulated, the following applies: Connections with flange ends must protrude at least 150 mm from the insulation of the main pipe, with coupling ends at least 40 mm (see item 2.3). For thicker insulation layers than those listed in the following tables, the minimum connection lengths must be calculated.

2.1 Lungimi de stuturi pentru conducte izolate

2.1 Connection lengths for insulated pipelines

Tab.1 / Tab.1

Lungimea minima a stuturilor / Minimum connection length

Grosimea stratului izolator al conductei principale/ Insulation thickness of the main pipe

Cu capete de flansa / with flange end

Cu capete de mufe / with coupling end

s L l 30 180 150 40 190 150 50 200 150 60 210 150 70 220 150 90 240 150 100 250 150 110 260 150 120 270 160 160 310 200 170 320 210 180 330 220 190 340 230 200 350 240 210 360 250 220 370 260 230 380 270 240 390 280 300 450 340 310 460 350 320 470 360 330 480 370 360 510 400

Page 4: Petrom OMV_Norm_H_1203_rom_eng_rev.2_2009-01-15

Pag 4 Norma Petrom OMV H 1203 / Petrom OMV Standard H 1203

Fig. 1 / Fig. 1

Da = Diametrul exterior al conductei s = Grosimea stratului de izolatie L = Lungimea stutului cu flansa l = Lungimea stutului cu mufa x = Da / 2 + L y = Da/2 + l

Da = Pipe outer diameter s = Insulation thickness L = Connection length with flange l = Connection length with coupling x = Da/2 + L y = Da/2 + l

Lungimile x si y se vor indica în desen. Dimensions x and y are given in the

drawing.

2.2 Lungimi de stuturi pentru conducte neizolate

2.2 Connection lengths for non-insulated pipelines

Lungimile stuturilor pentru conducte neizolate, cu capete de flanse si mufe, trebuie sa aiba lungimea minima 150 mm.

The connection lengths for non-insulated pipelines with flange and coupling ends must be at least 150 mm long.

Fig. 2 / Fig. 2

Da = diametrul exterior al conductei x = Da/2 + 150 y = Da/2 + 150

Da = Pipe outer diameter x = Da/2 + 150 y = Da/2 + 150

Marimile x si y se indica in desen. Dimensions x and y are given in the drawing.

Page 5: Petrom OMV_Norm_H_1203_rom_eng_rev.2_2009-01-15

Pag 5 Norma Petrom OMV H 1203 / Petrom OMV Standard H 1203

2.3 Lungimi pentru stuturi care sunt izolate împreuna

2.3 Connection lengths for connections that are also insulated

Lungimile stuturilor- vezi pct. 2.1

For connection lengths, see item 2.1

Fig. 3 / Fig. 3

Da = Diametrul exterior al conductei s = Grosimea stratului de izolatie L = Lungimea stutului cu flansa l = Lungimea stutului cu mufa x = Da / 2 + L y = Da / 2 + l

Da = Pipe outer diameter s = Insulation thickness L = Connection length with flange l = Connection length with coupling x = Da/2 + L y = Da/2 + l

Lungimile x si y se vor indica în desen. Dimensions x and y are given in the drawing.

Page 6: Petrom OMV_Norm_H_1203_rom_eng_rev.2_2009-01-15

Pag 6 Norma Petrom OMV H 1203 / Petrom OMV Standard H 1203

ANEXA 1– Norme si prescriptii ANNEX 1 - Standards and regulations

Norme Petrom OMV H 2202 Conducte- stuturi de aerisire, DIN si ANSI H 2203 Conducte - stuturi de golire, DIN si ANSI H 2204 Conducte - stuturi pentru ventile de siguranta pentru expansiune termica; DIN si ANSI H 2266 Conducte - stuturi pentru prize de presiune, DIN si ANSI H 2271 Conducte - stuturi pentru prelevare probe, DIN si ANSI

Petrom OMV standards H 2202 Piping - vent stubs, DIN and ANSI H 2203 Piping - drain stubs, DIN and ANSI H 2204 Piping - safety valve stubs for thermal

expansion; DIN and ANSI H 2266 Piping - pressure tapping stubs;

DIN and ANSI H 2271 Piping - sampling connections;

DIN and ANSI