UNIVERSITATEA TRANSILVANIA DIN BRAOV
FACULTATEA DE INGINERIE ELECTRIC
I TIINA CALCULATOARELOR
BUCK-BOOST CONVERTER FOR
WIND TURBINE BATTERY SYSTEM
Students:
ORZAN IULIAN-ALEXANDRU
POPESCU RADU-ANDREI
SEAGR.4797
7/28/2019 Proiect CAD
2/31
2
TABLE OF CONTENTS
1. Project description...32. Buck-boost converters.....43. Sizing active and passive components ............. 114. Modeling and simulation of buck-boost converter for WT battery system...125. Sizing semiconductorprotections. 146. Heat radiatorsizing157. Annex 1 - IRFB4310GPBF Data sheet.168. Annex 2 - Manual calculations..259. Bibliography..31
7/28/2019 Proiect CAD
3/31
3
1. Project descriptionFor the Buck-boost converter for WT battery system we established that we have to:
-
Established the structure (Fig.AWT Battery System)- Modelling the converter with ideal components- Simulation in Matlab- Calculation of the passive components- Calculation of the active components- Sizing of semiconductor elements and the heat sink
Fig.AWT Battery System
7/28/2019 Proiect CAD
4/31
4
2. Buckboost converterThis page describes the switched-mode power supply. For the autotransformer, see buck
boost transformer.
The basic schematic of a buckboost converter
Two different topologies are called buckboost converter. Both of them can produce an
output voltage much larger (in absolute magnitude) than the input voltage. Both of them can
produce a wide range of output voltage from that maximum output voltage to almost zero.
The inverting topologyThe output voltage is of the opposite polarity as the input A buck (step-down) converter followed by a boost (step-up) converter The outputvoltage is of the same polarity as the input, and can be lower or higher than the input. Such a
non-inverting buck-boost converter may use a single inductor that is used as both the buck
inductor and the boost inductor.
The buckboost converter is a type of DC-DC converter that has an output voltage
magnitude that is either greater than or less than the input voltage magnitude. It is a switch mode
power supply with a similar circuit topology to the boost converterand the buck converter. The
output voltage is adjustable based on the duty cycle of the switching transistor. One possible
drawback of this converter is that the switch does not have a terminal at ground; this complicates
the driving circuitry. Also, the polarity of the output voltage is opposite the input voltage.
Neither drawback is of any consequence if the power supply is isolated from the load circuit (if,
for example, the supply is a battery) as the supply and diode polarity can simply be reversed.The switch can be on either the ground side or the supply side.
Principle of operation
Fig. 1: Schematic of a buckboost converter.
Fig. 2: The two operating states of a buckboost converter
http://en.wikipedia.org/wiki/Switched-mode_power_supplyhttp://en.wikipedia.org/wiki/Autotransformerhttp://en.wikipedia.org/wiki/Buck%E2%80%93boost_transformerhttp://en.wikipedia.org/wiki/Buck%E2%80%93boost_transformerhttp://en.wikipedia.org/wiki/Buck%E2%80%93boost_transformerhttp://en.wikipedia.org/wiki/Buck_converterhttp://en.wikipedia.org/wiki/Boost_converterhttp://en.wikipedia.org/wiki/DC_to_DC_converterhttp://en.wikipedia.org/wiki/SMPShttp://en.wikipedia.org/wiki/SMPShttp://en.wikipedia.org/wiki/Boost_converterhttp://en.wikipedia.org/wiki/Buck_converterhttp://en.wikipedia.org/wiki/Duty_cyclehttp://en.wikipedia.org/wiki/File:Buckboost_operating.svghttp://en.wikipedia.org/wiki/File:Buckboost_conventions.svghttp://en.wikipedia.org/wiki/File:Buck_boost.pnghttp://en.wikipedia.org/wiki/File:Buckboost_operating.svghttp://en.wikipedia.org/wiki/File:Buckboost_conventions.svghttp://en.wikipedia.org/wiki/File:Buck_boost.pnghttp://en.wikipedia.org/wiki/File:Buckboost_operating.svghttp://en.wikipedia.org/wiki/File:Buckboost_conventions.svghttp://en.wikipedia.org/wiki/File:Buck_boost.pnghttp://en.wikipedia.org/wiki/Duty_cyclehttp://en.wikipedia.org/wiki/Buck_converterhttp://en.wikipedia.org/wiki/Boost_converterhttp://en.wikipedia.org/wiki/SMPShttp://en.wikipedia.org/wiki/SMPShttp://en.wikipedia.org/wiki/DC_to_DC_converterhttp://en.wikipedia.org/wiki/Boost_converterhttp://en.wikipedia.org/wiki/Buck_converterhttp://en.wikipedia.org/wiki/Buck%E2%80%93boost_transformerhttp://en.wikipedia.org/wiki/Buck%E2%80%93boost_transformerhttp://en.wikipedia.org/wiki/Autotransformerhttp://en.wikipedia.org/wiki/Switched-mode_power_supply7/28/2019 Proiect CAD
5/31
5
When the switch is turned-on, the input voltage source supplies current to the inductor and
the capacitor supplies current to the resistor (output load). When the switch is opened (providing
energy is stored into the inductor), the inductor supplies current to the load via the diode D.
The basic principle of the buckboost converter is fairly simple (see figure 2):
while in the On-state, the input voltage source is directly connected to the inductor (L).This results in accumulating energy in L. In this stage, the capacitor supplies energy to the
output load.
while in the Off-state, the inductor is connected to the output load and capacitor, soenergy is transferred from L to C and R.
Compared to the buckand boost converters, the characteristics of the buckboost converter
are mainly:
polarity of the output voltage is opposite to that of the input; the output voltage can vary continuously from 0 to (for an ideal converter). The
output voltage ranges for a buck and a boost converter are respectively 0 to and to .
Continuous Mode
Fig 3: Waveforms of current and voltage in a buckboost converter operating in continuous
mode
If the current through the inductorL never falls to zero during a commutation cycle, the
converter is said to operate in continuous mode. The current and voltage waveforms in an ideal
converter can be seen in Figure 3.
From to , the converter is in On-State, so the switch S is closed. The rate of
change in the inductor current (IL) is therefore given by
At the end of the On-state, the increase ofIL is therefore:
D is the duty cycle. It represents the fraction of the commutation period Tduring which the
switch is On. ThereforeD ranges between 0 (Sis never on) and 1 (Sis always on).
During the Off-state, the switch Sis open, so the inductor current flows through the load. If
we assume zero voltage drop in the diode, and a capacitor large enough for its voltage to remain
constant, the evolution ofIL is:
http://en.wikipedia.org/wiki/Buck_converterhttp://en.wikipedia.org/wiki/Boost_converterhttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram.svghttp://en.wikipedia.org/wiki/Boost_converterhttp://en.wikipedia.org/wiki/Buck_converter7/28/2019 Proiect CAD
6/31
6
Therefore, the variation ofIL during the Off-period is:
As we consider that the converter operates in steady-state conditions, the amount of energy
stored in each of its components has to be the same at the beginning and at the end of a
commutation cycle. As the energy in an inductor is given by:
it is obvious that the value ofIL at the end of the Off state must be the same as the value ofIL
at the beginning of the On-state, i.e. the sum of the variations ofIL during the on and the off
states must be zero:
Substituting and by their expressions yields:
This can be written as:
This in return yields that:
From the above expression it can be seen that the polarity of the output voltage is alwaysnegative (as the duty cycle goes from 0 to 1), and that its absolute value increases with D,
theoretically up to minus infinity as D approaches 1. Apart from the polarity, this converter is
either step-up (as a boost converter) or step-down (as a buck converter). This is why it is referred
to as a buckboost converter.
Discontinuous Mode
Fig 4: Waveforms of current and voltage in a buckboost converter operating in
discontinuous mode
http://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buckboost_chronogram_discontinuous.png7/28/2019 Proiect CAD
7/31
7
In some cases, the amount of energy required by the load is small enough to be transferred in
a time smaller than the whole commutation period. In this case, the current through the inductor
falls to zero during part of the period. The only difference in the principle described above is that
the inductor is completely discharged at the end of the commutation cycle (see waveforms infigure 4). Although slight, the difference has a strong effect on the output voltage equation. It
can be calculated as follows:
As the inductor current at the beginning of the cycle is zero, its maximum value (at
) is
During the off-period,ILfalls to zero after .T:
Using the two previous equations, is:
The load currentIo is equal to the average diode current (ID). As can be seen on figure 4, the
diode current is equal to the inductor current during the off-state. Therefore, the output currentcan be written as:
Replacing and by their respective expressions yields:
Therefore, the output voltage gain can be written as:
Compared to the expression of the output voltage gain for the continuous mode, this
expression is much more complicated. Furthermore, in discontinuous operation, the outputvoltage not only depends on the duty cycle, but also on the inductor value, the input voltage and
the output current.
7/28/2019 Proiect CAD
8/31
8
Limit between continuous and discontinuous modes
Fig 5: Evolution of the normalized output voltage with the normalized output current in a
buckboost converter
As told at the beginning of this section, the converter operates in discontinuous mode when
low current is drawn by the load, and in continuous mode at higher load current levels. The limit
between discontinuous and continuous modes is reached when the inductor current falls to zero
exactly at the end of the commutation cycle. with the notations of figure 4, this corresponds to :
In this case, the output current (output current at the limit between continuous and
discontinuous modes) is given by:
Replacing by the expression given in the discontinuous mode section yields:
As is the current at the limit between continuous and discontinuous modes of
operations, it satisfies the expressions of both modes. Therefore, using the expression of the
output voltage in continuous mode, the previous expression can be written as:
Let's now introduce two more notations:
the normalized voltage, defined by . It corresponds to the gain in voltage of theconverter;
the normalized current, defined by . The term is equal to the maximumincrease of the inductor current during a cycle; i.e., the increase of the inductor current with a
duty cycle D=1. So, in steady state operation of the converter, this means that equals 0 for no
output current, and 1 for the maximum current the converter can deliver.
http://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.pnghttp://en.wikipedia.org/wiki/File:Buck-boost_continuous_discontinuous.png7/28/2019 Proiect CAD
9/31
9
Using these notations, we have:
in continuous mode, ; in discontinuous mode, ;
the current at the limit between continuous and discontinuous mode is. Therefore the locus of the limit between continuous and
discontinuous modes is given by .
These expressions have been plotted in figure 5. The difference in behaviour between the
continuous and discontinuous modes can be seen clearly.
Non-ideal circuit
Effect of parasitic resistances
Fig 6: Evolution of the output voltage of a buckboost converter with the duty cycle whenthe parasitic resistance of the inductor increases
In the analysis above, no dissipative elements (resistors) have been considered. That means
that the power is transmitted without losses from the input voltage source to the load. However,
parasitic resistances exist in all circuits, due to the resistivity of the materials they are made
from. Therefore, a fraction of the power managed by the converter is dissipated by these
parasitic resistances.
For the sake of simplicity, we consider here that the inductor is the only non-ideal
component, and that it is equivalent to an inductor and a resistor in series. This assumption is
acceptable because an inductor is made of one long wound piece of wire, so it is likely to exhibit
a non-negligible parasitic resistance (RL). Furthermore, current flows through the inductor both
in the on and the off states.
Using the state-space averaging method, we can write:
where and are respectively the average voltage across the inductor and the switch over
the commutation cycle. If we consider that the converter operates in steady-state, the average
current through the inductor is constant. The average voltage across the inductor is:
When the switch is in the on-state, . When it is off, the diode is forward biased (we
consider the continuous mode operation), therefore . Therefore, the average voltageacross the switch is:
http://en.wikipedia.org/wiki/Resistorhttp://en.wikipedia.org/wiki/Resistivityhttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/File:Buckboost_resistance.svghttp://en.wikipedia.org/wiki/Resistivityhttp://en.wikipedia.org/wiki/Resistor7/28/2019 Proiect CAD
10/31
10
The output current is the opposite of the inductor current during the off-state. the average
inductor current is therefore:
Assuming the output current and voltage have negligible ripple, the load of the converter can
be considered as purely resistive. If R is the resistance of the load, the above expression
becomes:
Using the previous equations, the input voltage becomes:
This can be written as:
If the inductor resistance is zero, the equation above becomes equal to the one of the ideal
case. But asRL increases, the voltage gain of the converter decreases compared to the ideal case.
Furthermore, the influence ofRL increases with the duty cycle. This is summarized in figure 6.
7/28/2019 Proiect CAD
11/31
11
3. Sizing active and passive componentsStarting from the WT battery system scheme (Fig.A) and the buck-boost equations:
Voltage transfer function (CCM)
soV
D
DV
1
Current transfer function (CCM)
soI
D
DI
1
Boundary between CCM and DCM (L design 1)
Maximum current ripple through L (L design 2)
fL
DVI sL
Voltage output ripple (C design)
, we made the active and passive components sizing.
Input data:
Us=[2060] V
Ubat=[38,457,6] V
P=500 W
Pmin = 10%*P=50 W
The worst case scenario: Us=60V and Ubat=38,4V
Rezults:
D=0,39
Rmin=29,5
Lb=270H
L1=1440 H
L=max(Lb,L1)=1440 H
Cmin=66 F
For detailed calculations see Annex 2.
7/28/2019 Proiect CAD
12/31
12
4. Modeling and simulation of buck-boost converter for WT battery system
Fig.7 WT Battery System Mathlab Simulation
Fig.8 Current graph from Scope
7/28/2019 Proiect CAD
13/31
13
Fig.9 Voltage graph from Scope1
7/28/2019 Proiect CAD
14/31
14
5. Sizing semiconductor protectionsUsing the calculated data from chapter 3 we determined the current and the voltage used in
transistor sizing.
IT,calc=91,63A
I T=128,2A
U T,calc=57,6V
U T=86,4V
According to this calculation we choose MOSFET IRFB4310GPbF fromwww.irf.com.
The transistor data sheet can be found in Annex 1.
Fig.10 Basic specifications
http://www.irf.com/http://www.irf.com/http://www.irf.com/http://www.irf.com/7/28/2019 Proiect CAD
15/31
15
6. Heat radiator sizingWe calculated the dissipated power (Pd) using the data sheet MOSFET information from
Annex 1.
Pd=18,56W
From the MOSFET data sheet we identified the maximum operating temperature and the
usual ambient temperature and calculated the thermal resistance from sink to ambient.
Rsa=4,38C/W
According to this we selected the heat sink no.2 from CAD Course 5 with the parameters:
Rsa=2,3C/W and a volume of 99 cm3.
7/28/2019 Proiect CAD
16/31
16
7. Annex 1 - IRFB4310GPBF Data sheet
7/28/2019 Proiect CAD
17/31
17
7/28/2019 Proiect CAD
18/31
18
7/28/2019 Proiect CAD
19/31
19
7/28/2019 Proiect CAD
20/31
20
7/28/2019 Proiect CAD
21/31
21
7/28/2019 Proiect CAD
22/31
22
7/28/2019 Proiect CAD
23/31
23
7/28/2019 Proiect CAD
24/31
24
7/28/2019 Proiect CAD
25/31
25
8. Annex 2 - Manual calculations
7/28/2019 Proiect CAD
26/31
26
7/28/2019 Proiect CAD
27/31
27
7/28/2019 Proiect CAD
28/31
28
7/28/2019 Proiect CAD
29/31
29
7/28/2019 Proiect CAD
30/31
30
7/28/2019 Proiect CAD
31/31
9. Bibliography[1]www.wikipedia.org
[2]
https://ec.irf.com/v6/en/US/adirect/ir?cmd=catProductDetailFrame&productID=IR
FB4310GPBF
http://www.wikipedia.org/http://www.wikipedia.org/http://www.wikipedia.org/https://ec.irf.com/v6/en/US/adirect/ir?cmd=catProductDetailFrame&productID=IRFB4310GPBFhttps://ec.irf.com/v6/en/US/adirect/ir?cmd=catProductDetailFrame&productID=IRFB4310GPBFhttps://ec.irf.com/v6/en/US/adirect/ir?cmd=catProductDetailFrame&productID=IRFB4310GPBFhttps://ec.irf.com/v6/en/US/adirect/ir?cmd=catProductDetailFrame&productID=IRFB4310GPBFhttps://ec.irf.com/v6/en/US/adirect/ir?cmd=catProductDetailFrame&productID=IRFB4310GPBFhttp://www.wikipedia.org/