    GRUNDFOS DATA BOOKLET

    Pumping station systems

    PS.G

    Pumping station, glass-fibre-reinforced plastic (GRP)

  • 8/19/2019 Statii de pompare prefabricate

    2/44

    T ab l  eof  cont  ent  s

    2

    Pumping station systems

    1. Introduction 3Introduction 3

     Applications 3

    Product features 3

    Liquids 3

    2. Identification 4PS.S 4

    PS.G 5

    3. Selection of products 6Ordering a pumping station 6

    Selection tool 7

    4. CE mark 8

    5. Product range 9Pipes 9

    Direction of outlet 11

    Pumping stations and pipe variants 12

    Other product variants 16

    6. Construction 17Pumping station 17

    Valve chamber 18

    Pumping station variants 19

    Covers 20

    Venting pipes 21

    Control cabinets 21

    Service platforms 21

    Baffle plates 21

    Screen baskets 22

    Level controllers 22

    7. Accessories 23Pump controllers 23

     AUTO ADAPT  pumps 26

    8. Installation 28Transportation and handling 28

     Acceptance inspection 28

    Installation of pumping station 29

    Backfill 31

    Pump 31

    Electrical installation 31

    Commissioning 31

    9. Dimensions 32

    Starting frequency 32Sump volume 32

    Dimensions of pumping station 33

    Dimensions of valve chamber 34

    Dimensions of the foundation slab 35

    Dimensions of concrete covers 38

    10. Grundfos Product Center 42

  • 8/19/2019 Statii de pompare prefabricate

    3/44

       I  n   t  r  o   d  u  c   t   i  o  n

    3

    Pumping station systems 1

    1. Introduction

    Introduction

    This data booklet deals with Grundfos prefabricated

    pumping stations, types PS.S and PS.G.

    Fig. 1 Grundfos pumping station

    The pumping station is made of glass-fibre-reinforced

    plastic (GRP) and comes with inlet and outlet pipes

    pre-fitted. Pumps may be supplied separately.

    The pipes are made of polyethylene (PE) or stainless

    steel (AISI 304).

    The pumping stations come in many variants and for a

    range of applications. Special variants are available on

    request.

    Pumping stations are also available with a separatevalve chamber enabling the operator to access valves

    without having to enter the station.

    The standard cover comes in GRP and the hatch in

    aluminium.

    Applications

    Grundfos prefabricated pumping stations are used for

    the collection and pumping of drainage water, grey

    wastewater and sewage. The type of pump depends

    on the liquid being pumped.

    Wastewater is led into the pit. When the liquid in the pit

    reaches the start level, the pump will start moving it onto a sewer or sewage treatment plant.

    Product features

    Corrosion-free materials

    Pipes are made of stainless steel or polyethylene.

    Modular flexibility

    The pumping stations consist of four main elements:

    • two or three high-efficiency pumps

    • pit size suitable for several requirements

    • factory-fitted pipes, valves and controllers ensure

    operational efficiency and safety

    • standard covers and covers approved for traffic.

    Many sizes available

    Our pumping stations come in a full range of sizes.

    Easy to install and service

    The pumping station is mounted on a concrete

    foundation to prevent uplift when installed in areas withhigh groundwater levels.

    The components of the pumping station are selected

    according to Grundfos principles of high reliability, long

    life and great consideration for the environment during

    production, operation and disposal.

    Liquids

    Liquid temperature

    Maximum liquid temperature is 40 °C. For higher

    temperatures, contact Grundfos.

    The liquid temperature depends on the pump selected.

    See the installation and operating instructions for the

    pump.

    pH value

    The pit is normally capable of withstanding pH values

    between 5.5 to 8.0. In case of doubt or another pH

    value, contact Grundfos.

    Viscosity

    Very thick wastewater must not be led into the pit. See

    the installation and operating instructions for the pump

    or Grundfos Product Center at www.Grundfos.com.

    Density

    Maximum 1100 kg/m3.

       T   M   0   6   4   0   0

       9   1   4   1   5

  • 8/19/2019 Statii de pompare prefabricate

    4/44

    I  d ent  i  f  i  cat  i  on

    4

    Pumping station systems2

    2. Identification

    PS.S

    Nameplate

    If a complete pumping station has been configured in

    the PUMPING STATION CREATOR atwww.Grundfos.com, the nameplate shown below will

    be added to the pit together with a CE mark. See

    section Selection tool  on page 7. At the same time

    Grundfos will deliver an EC declaration of conformity in

    accordance with the Machinery Directive (2006/42/EC)

    EN ISO 12100:2010.

    Fig. 2 Nameplate of PS.S pumping stations

    Type key

       T   M   0   6   1   7   4   3   2   7   1   4

    Pos. Description

    1 Product number  

    2 Production site

    3 Type designation

    4 Country of origin

    5 Weight

    6 Production code and date of production (YYWW)

    7 Installation and operating instructions, publication number 

    8 Product number, pumping station

    9 Product number, pump

    10 Product number, pump controller 

    11 Product number, level controller 

    12 Product number, accessories

    13 Not filled in

    1 2

    3

    4

    9

    10

    11

    12

    5

    6  7

    8 13 13

    Example PS S. G. 18. 40. SE/SL. DCD318. PT

    Grundfos pumping station

    System

    Pit type and materialR: Rotation-moulded PEG: Glass-fibre reinforced plastic

    Pit diameter 18: 1800 mm

    Pit depth x 10040: 4000 mm

    Pump typeCC: Unilift CCKP: Unilift KP

     AP12: Unilift AP12.50 AP35: Unilift AP35, Unilift AP12.40 AP50: Unilift AP50 APB: Unilift AP35B, Unilift AP50BSEG: SEG, SEG AUTO ADAPT DP, EF: DP (0.6 - 1.5 kW), EFDP, SL: DP (2.6 kW), SL1.50.65, SLV.65.65SE, SL: SE, SLS: S-pump

    Pump controller LC 108: Level controller LCD 108: Level controller, two pumpsDC 318: Dedicated ControlsDC 319: Dedicated ControlsDCD 318: Dedicated Controls, two pumpsDCD 319: Dedicated Controls, two pumps

    Level controller FS2: Two float switchesFS3: Three float sw itchesFS4: Four float switchesPT: Pressure transducer  

  • 8/19/2019 Statii de pompare prefabricate

    5/44

       I   d  e  n   t   i   f   i  c  a   t   i  o  n

    5

    Pumping station systems 2

    PS.G

    Nameplate

    The nameplate shown below is the standard

    nameplate that provides information about the

    pumping station and carries the CE mark of the

    pumping station.

    Declaration of performance is in accordance with

     Annex III of Regulation (EU) No 305/2011

    (Construction Product Regulation).

    Fig. 3 Nameplate of PS.G pumping stations

    Type key

       T   M   0

       6   3   8   3   6   1   0   1   5

    Pos. Description

    1 Product number  

    2 Production site

    3 Type designation

    4 Country of origin

    5 Weight

    6 Production code and date of production (YYWW)

    7 Installation and operating instructions, publication number 

    8 Not filled in

    Type

    Standards used: EN 12050-1 or EN 12050-2

    Model

    Weight

    P.c.

    Made in

    EU declaration of performance

    P10

    962352181325

    Notified body:0197 DK-8850 Bjerringbro, Denmark   9      8      4      9      5      4      9      0

    1 3 2

    74   8 56

    Example PS. G. 18. 40 D. GC SS100. A100. SE/SL

    Pumping station

    Glass-fibre reinforced plastic

    Pit diameter 18: 1800 mm

    Pit depth x 10040: 4000 mm

    Number of pumpsS: OneD: TwoT: Three

    Pipe designDC: Direct outlet, commonGC: Goose neck, commonVC: Valve chamber  

    Pipe material and pipe diameter

    Stainless steel:SS50: DN 50 (2")SS65: DN 65 (2 1/2")SS80: DN 80 (3")SS100: DN 100 (4" )SS150: DN 150 (6" )SS200: DN 200 (8" )

    Polyethylene:PE63: D63 mm (2")PE75: D75 mm (2 1/2")PE90 D90 mm (3")PE110: D110 mm (4" )PE160: D160 mm (6" )

    Installation typeAuto coupling:

     A50: DN 50 pump connection A65: DN 65 pump connection A80: DN 80 pump connection A100: DN 100 pump connection A150: DN 150 pump connection A200: DN 200 pump connection

    Pump typeSEG: SEG and SEG AUTO ADAPT DP/EF: DP (0.6 - 1.5 kW) / EFDP/SL: DP (2.6 kW) / SL1.50.65 / SLV.65.65SE/SL: SE/SLS: S-pump

  • 8/19/2019 Statii de pompare prefabricate

    6/44

    S el  ect  i  onof  pr o

    d uct  s

    6

    Pumping station systems3

    3. Selection of products

    Ordering a pumping station

    When ordering a Grundfos GS.S or GS.G pumping

    station, take the following into consideration:

    • pump type (possible custom-built variant)

    • pipe material

    • pit diameter and depth

    • insulation of the pit (optional)

    • valve chamber (optional)

    • accessories such as controllers.

    You can configure the pumping station system in

    Grundfos Product Center at www.Grundfos.com by

    using the selection tool. In this case all the

    requirements must be known.

    Pump type

    The pumping stations can be equipped with the

    following pumps:• DP, EF and AUTO ADAPT  pumps (0.6 - 1.5 kW)

    • SL1, SLV and AUTO ADAPT  pumps (0.9 - 2.6 kW)

    • SEG and SEG AUTO ADAPT  grinder pumps (0.9 - 4.0

    kW)

    • SE, SL pumps (0.9 - 30 kW)

    • S-pumps up to range 70 (up to 155 kW).

    Note: Data for a specific pump can be found in the

    pump data booklet or in Grundfos Product Center at

    www.Grundfos.com.

    For further info about Grundfos Product Center, see

    page 42.

    Pump installationThe pumps are installed on an auto coupling at the

    bottom of the pit.

    See section Installation on page 28.

    Pipe material

    Pipes are made of PE (polyethylene) or stainless steel

    (SS, AISI 304). See section Other product variants on

    page 16.

    Pump pit

    The pits come various sizes and with various standard

    fittings. See section Dimensions on page 32 and

    Starting frequency  on page 32 to calculate the volume

    needed.

    Valve chamber 

    The valve chamber is separate pit that can be selected

    to house equipment so that service personnel need not

    enter the pit.

    Pump controllers and level control systems

    The following controllers are available for standard

    pumps:

    • Dedicated Controls (DC, DCD). See page 23.

    • LC and LCD 108 operated by float switches. Seepage 24.

    • CU 100 (optional). See page 25.

    The following controllers are available for AUTO ADAPT  

    pumps:

    • Built-in controller. See page 26.

    • Grundfos CIU. See page 26.

    • Grundfos GO. See page 26.

    For pump controllers, see section Pump controllers on

    page 23 or in Grundfos Product Center at

    www.Grundfos.com.

    Accessories

    Depending on the installation type, accessories may

    be required. For selection of the correct accessories,

    see section Pump controllers on page 23.

    Note: Some of the accessories can be fitted from

    factory. Contact Grundfos.

  • 8/19/2019 Statii de pompare prefabricate

    7/44

       S  e   l  e  c   t   i  o  n  o   f  p  r  o   d  u  c   t  s

    7

    Pumping station systems 3

    Selection tool

    You can f ind the selection tool PUMPING STATION

    CREATOR in Grundfos Product Center at

    www.Grundfos.com.

    Fig. 4 Selection tool in Grundfos Product Center 

    1. Input your requirements

    Here you enter information about flow rate, head,number of pumps and operating mode. This

    ensures we offer the right pump for the task.

    Information about the depth of the lowest inlet to

    the pumping station is also required to get some

    good suggestions for solutions.

    The selection tool offers a list of pumps from which

    you can select the pump required.

    2. Select a solution

    Here a number of possible solutions are presented,

    and you can select the one that fits your

    requirements.

    3. Configure & customize

    Here you can make the detailed configuration of theselected solutions. Drawings of the selected

    solution are presented.

    4. Pick your accessories

    Here you can select accessories for your

    customised solution.

    5. Print or e-mail your order 

    Here the final solution is presented as a CAD

    drawing that can be downloaded. Specification

    reports for the customised solution can be

    generated, printed and sent to Grundfos.

    This is the information Grundfos needs to give you

    a quotation and lead time for delivery.

       T   M   0   6   3   4   9   7   0   4   1   5

  • 8/19/2019 Statii de pompare prefabricate

    8/44

    C E mar k 

    8

    Pumping station systems4

    4. CE mark

    Pumping station

    The pumping stations are CE-certified modules. The

    declaration of performance is in accordance with

     Annex III of Regulation (EU) No 305/2011

    (Construction Product Regulation).

    Pumps and controllers

    Depending on the pumps and controllers selected, the

    pumping stations are in accordance with one or

    several of the following directives:

    • EMC Directive (2004/108/EC)

    • Low Voltage Directive (2006/95/EC)

    • ATEX Directive (94/9/EC)

    • Machinery Directive (2006/42/EC).

    The declaration of conformity can be found in the

    installation and operating instructions for the products.

    CE-certified complete system

    The standard range in Grundfos Product Center makesit possible to obtain the EC declaration of conformity in

    accordance with the Machinery Directive (2006/42/EC)

    EN ISO 12100:2010.

    Other main approvals and standards

    • EN12050-1 and EN 12050-2

    Wastewater lifting plants for buildings and sites.

    Principles of construction and testing. Lifting plants

    for wastewater containing faecal matter.

    • EN 752

    Drain and sewer systems outside buildings

    • EN 124

    Gully tops and manhole tops for vehicular andpedestrian ares. Design requirements, type testing,

    marking and quality control.

    • EN 1917:2002

    Concrete manholes and inspection chambers,

    unreinforced, steel fibre and reinforced.

  • 8/19/2019 Statii de pompare prefabricate

    9/44

       P  r  o   d  u  c   t  r  a  n  g  e

    9

    Pumping station systems 5

    5. Product range

    Pipes

    Pipe variants

    Pumping stations have three main pipe variants:

    • Goose neck (GC), common. See fig. 5.

    • Direct outlet (DC), common. See fig. 6.

    • Valve chamber (VC). See fig. 7.

    Custom-made pipes are available on request. Contact

    Grundfos.

    Fig. 5 GC, pipe system with goose neck

    Fig. 6 DC, pipe system with direct outlet

    Fig. 7 VC, valve chamber (no valves inside the pumping

    station)

       T   M   0   5   3   3   1   9   1   1   1   2  -   T   M   0   6   3   5   7   7   0   6   1   5

    Goose neck, stainless steel (SS) Goose neck, polyethylene (PE)

       T   M   0   6   2   9   3   1   4   8   1   4

       T   M   0   6   3   8   4   8   1   0   1   5

  • 8/19/2019 Statii de pompare prefabricate

    10/44

    P r od uct  r ange

    10

    Pumping station systems5

    Pipe sizes

    Pipes are offered in stainless steel (SS) or

    polyethylene (PE). Some pit sizes are not available

    with all variants. See section Pipe variants on page 9.

    Stainless steel, SS - AISI 304

    * This variant is also applicable for pits with three pumps.

    Polyethylene, PE

    Pipe size

    Pit diameter 

    [mm]

    1200-1400 1600-1800 2000-2200 3000

    GC DC VC GC DC VC GC DC VC GC DC* VC

    DN 50   ● ● ● ● ● ●

    DN 65   ● ● ● ● ● ● ● ● ●

    DN 80   ● ● ● ● ● ● ● ● ● ● ● ●

    DN 100   ● ● ● ● ● ● ● ● ●

    DN 150   ● ● ● ● ● ●

    DN 200   ● ●

    DN 250   ● ●

    Pipe size

    Pit diameter [mm]

    1200-1400 1600-1800 2000-2200 3000

    GC DC VC GC DC VC GC DC VC GC DC VC

    D63   ● ● ● ● ● ●

    D75   ● ● ● ● ● ● ● ● ●

    D90   ● ● ● ● ● ● ● ● ● ● ● ●

    D110   ● ● ● ● ● ● ● ● ●

    D160   ● ● ● ● ● ●

  • 8/19/2019 Statii de pompare prefabricate

    11/44

       P  r  o   d  u  c   t  r  a  n  g  e

    11

    Pumping station systems 5

    Direction of outlet

    The direction of the outlet depends on the diameter of

    the pit and the pipe type. The outlet is always shown

    with either degrees or time o'clock.

    Stainless-steel pipes (SS)

    Pits with a diameter up to 3000 mm and stainless-steel

    pipes can be delivered with VC, DC and GC pipes. Thepipes determine the direction of outlet. See figures 8 

    and 9.

    Fig. 8 Direction of outlet of a 2-pump installation, VC

    pipes (valve chamber)

    Fig. 9 Direction of outlet of ∅3000 pits with DC and GC

    pipes

    Figure 10 shows the offset of ∅3000 pits.

    Fig. 10 Offset

    Pits with stainless-steel pipes and a diameter of 1200

    to 2200 mm can be delivered with VC, DC and GC

    pipes. The outlet is always 0 °. See fig. 11.

    Polyethylene pipes (PE)

    In pits with PE pipes and a diameter up to 3000 mm

    the direction of the outlet is always 0 °.

    Fig. 11 Direction of outlet of pits up to ∅3000

       T   M   0   6   3   4   1   9   0   2   1   5

       T   M   0   6   3   5   1   3   0   6   1   5

       T   M   0   6   3   9   1   2   1   2   1   5

    0 ° (0:00 / 12:00)

    270 °(9:00)

    90 °(3:00)

     A = xxx ± 50 Pipes[DN]

    A[mm]

    250 / 300 510

    250 / 250 485

    200 / 250 502

    200/ 200 475

    150 / 200 475

    150 / 150 450

    100 / 150 450

    100 / 100 390

    80 / 100 390

    80 / 80 370

     A

       T   M   0   6   3   3   3   6   5   1   1   4

    0 ° (0:00 / 12:00)

  • 8/19/2019 Statii de pompare prefabricate

    12/44

    P r od uct  r ange

    12

    Pumping station systems5

    Pumping stations and pipe variants

    Pumping stations come in various diameters and with

    a number of pump and pipe combinations.

    Not all pump variants are available across the ranges.

    For more information, contact Grundfos.

    S-pumps are available from range 50 to 70 (up to 255

    kW) in S1, S2 and SV variants.

    DN 50 stainless-steel pipes and D63 PE pipes

    DN 40 pumps are only available with DN 50 pipes.

    * For more information about pipes, see section Other product variants on page 16.

    Pumptype

    Installation type*Pipe

    material

    Pit diameter [mm]

    1200 1400 1600 1800 2000 22003000

    2 pumps3000

    3 pumps

       S   E   G ,   D   P ,   E   F ,   A   U   T   O     A     D     A     P     T

    Pump with DC or VC pipesSS   ● ● ● ●

    PE   ● ● ● ●

    Pump with GC pipesSS   ● ● ● ●

    PE   ● ● ● ●

    Pump with DC or VC pipes + smallscreen basket

    SS   ● ● ●

    PE   ● ● ●

    Pump with GC pipes + small screenbasket

    SS   ● ● ●

    PE   ● ● ●

    Pump with DC or VC pipes + bigscreen basket

    SS

    PE

    Pump with GC pipes + big screenbasket

    SS

    PE

    Pump with DC or VC pipes + EN 124cover, ∅600 mm

    SS   ● ● ● ●

    PE   ● ● ● ●

    Pump with GC pipes + EN 124cover, ∅600 mm

    SS   ● ● ● ●

    PE   ● ● ● ●

    Pump with DC or VC pipes + EN 124cover, ∅800 mm

    SS   ● ● ● ●

    PE   ● ● ● ●

    Pump with GC pipes + EN 124cover, ∅800 mm

    SS   ● ● ● ●

    PE   ● ● ● ●

    Pump with DC or VC pipes + smallbaffle plate

    SS   ● ● ● ●

    PE   ● ● ● ●

    Pump with GC pipes + small baffleplate

    SS   ● ● ● ●

    PE   ● ● ● ●

    Pump with DC or VC pipes + bigbaffle plate

    SS   ● ● ●

    PE   ● ● ●

    Pump with GC pipes + big baffleplate

    SS   ● ● ●

    PE   ● ● ●

  • 8/19/2019 Statii de pompare prefabricate

    13/44

       P  r  o   d  u  c   t  r  a  n  g  e

    13

    Pumping station systems 5

    DN 65 and DN 80 stainless-steel pipes and D75 and D90 PE pipes

    * For more information about pipes, see section Other product variants on page 16.1) Only SE and SL pump variants are available. Contact Grundfos.

    2) Only available for SE1.50.65, 80.22, 30.2, and SL1.50.65, 80.22 and 30.3) Only available for SE and SL.4) Only available with DN 80 or D90 DC pipes.

    Pumptype

    Installation type*Pipe

    material

    Pit diameter [mm]

    1200 1400 1600 1800 2000 22003000

    2 pumps3000

    3 pumps

       S   E   1

     ,   S   L   1 ,   S   L   V ,   S   E   V

       S  -  p

      u  m  p  s ,  r  a  n  g  e   5   0

    Pump with DC or VC pipesSS   ●1) ● ● ● ● ● ● ●4)

    PE   ●1)

    ● ● ● ● ● ●

    Pump with GC pipesSS   ●1) ● ● ● ● ● ●

    PE   ●1) ● ● ● ● ● ●

    Pump with DC or VC pipes + smallscreen basket

    SS   ●2) ● ● ● ● ● ●4)

    PE   ●2) ● ● ● ● ●

    Pump with GC pipes + small screenbasket

    SS   ●2) ● ● ● ● ●

    PE   ●2) ● ● ● ● ●

    Pump with DC or VC pipes + bigscreen basket

    SS   ● ● ● ●4)

    PE   ● ● ●

    Pump with GC pipes + big screenbasket

    SS   ● ● ●

    PE   ● ● ●

    Pump with DC or VC pipes + EN 124cover, ∅800 mm

    SS   ●1) ●3) ●3) ●1)

    PE   ●1) ●3) ●3) ●1)

    Pump with GC pipes + EN 124cover, ∅800 mm

    SS   ●1) ●3) ●3) ●1)

    PE   ●1) ●3) ●3) ●1)

    Pump with DC or VC pipes + smallbaffle plate

    SS   ●1) ● ● ● ● ● ●4)

    PE   ●1) ●3) ● ● ● ●

    Pump with GC pipes + small baffleplate

    SS   ●1) ●3) ● ● ● ●

    PE   ●1) ●3) ● ● ● ●

    Pump with DC or VC pipes + bigbaffle plate

    SS   ●1) ● ● ● ● ●4)

    PE   ●1) ● ● ● ●

    Pump with GC pipes + big baffleplate

    SS   ●1) ● ● ● ●

    PE   ●1) ● ● ● ●

  • 8/19/2019 Statii de pompare prefabricate

    14/44

    P r od uct  r ange

    14

    Pumping station systems5

    DN 100 stainless-steel pipes and D110 PE pipes

    * For more information about pipes, see section Other product variants on page 16.1) Limited range of SE and SL pump variants available. Contact Grundfos.

    2) Not available for SE1.100.100.40, 55 and 75.4, and SL1.100.100.40, 55 and 75.3) Limited range of SE and SL pump variants available. Not available with S-pumps. Contact Grundfos.4) Only available with DC pipes.

    Pumptype

    Installation type*Pipe

    material

    Pit diameter [mm]

    1200 1400 1600 1800 2000 22003000

    2 pumps3000

    3 pumps

       S   E   1

     ,   S   L   1 ,   S   L   V ,   S   E   V

       S  -  p  u  m  p

      s ,  r  a  n  g  e  s   5   0  a  n   d   5   4

    Pump with DC or VC pipesSS   ● ● ● ● ● ●

    PE   ● ● ● ● ●

    Pump with GC pipesSS   ● ● ● ● ●

    PE   ● ● ● ● ●

    Pump with DC or VC pipes + smallscreen basket

    SS   ● ● ● ● ● ●4)

    PE   ● ● ● ● ●

    Pump with GC pipes + small screenbasket

    SS   ● ● ● ● ●

    PE   ● ● ● ● ●

    Pump with DC or VC pipes + bigscreen basket

    SS   ● ● ● ●4)

    PE   ● ● ●

    Pump with GC pipes + big screenbasket

    SS   ● ● ●

    PE   ● ● ●

    Pump with DC or VC pipes + EN 124cover, ∅800 mm

    SS   ●3)

    PE   ●3)

    Pump with GC pipes + EN 124cover, ∅800 mm

    SS   ●3)

    PE   ●3)

    Pump with DC or VC pipes + smallbaffle plate

    SS   ●2) ●2) ● ● ● ●4)

    PE   ●2) ●2) ● ● ●

    Pump with GC pipes + small baffleplate

    SS   ●2) ●2) ● ● ●

    PE   ●2) ●2) ● ● ●

    Pump with DC or VC pipes + bigbaffle plate

    SS   ●1) ●1) ● ● ● ●4)

    PE   ●1) ●1) ● ● ● ●4)

    Pump with GC pipes + big baffleplate

    SS   ●1) ●1) ● ● ● ●

    PE   ●1) ●1) ● ● ● ●

  • 8/19/2019 Statii de pompare prefabricate

    15/44

       P  r  o   d  u  c   t  r  a  n  g  e

    15

    Pumping station systems 5

    DN 150 stainless steel-pipes and D160 PE pipes

    * For more information about pipes, see section Other product variants on page 16.1) In SE and SL ranges only available for SE1.100.150.40 and 55.4, and SL1.100.150.40 and 55.2) In SE and SL ranges only available for SE1.100.150.40 and 55.4, and SL1.100.150.40, 55 and 75.3) Only available with DC pipes.

    DN 200 and DN 250 stainless-steel pipes

    * For more information about pipes, see section Other product variants on page 16.1) Only available with DN 200 pressure flange and for DC pipes.

    Pumptype

    Installation type*Pipe

    material

    Pit diameter [mm]

      1200   1400   1600   1800   2000   2200  3000

    2 pumps  3000

    3 pumps

       S   E   1 ,   S   L   1 ,   S   L   V ,   S   E   V

       S  -

      p  u  m  p  s ,  r  a  n  g  e  s   5   0 ,   5   4  a  n   d   6   2

    Pump with DC or VC pipesSS   ● ● ● ●3)

    PE   ● ● ●

    Pump with GC pipesSS   ●1) ●1) ●

    PE   ●1) ●1) ●

    Pump with DC or VC pipes + smallscreen basket

    SS   ● ● ● ●3)

    PE   ● ● ●

    Pump with GC pipes + small screenbasket

    SS   ●1) ●2) ●

    PE   ●1) ●2) ●

    Pump with DC or VC pipes + bigscreen basket

    SS   ● ● ● ●3)

    PE   ● ● ●

    Pump with GC pipes + big screenbasket

    SS   ●1) ●2) ●

    PE   ●1) ●2) ●

    Pump with DC or VC pipes + smallbaffle plate

    SS   ● ● ● ●3)

    PE   ● ● ●

    Pump with GC pipes + small baffleplate

    SS   ●1) ●1) ●

    PE   ●1) ●2) ●

    Pump with DC or VC pipes + bigbaffle plate

    SS   ● ● ● ●3)

    PE   ● ● ●

    Pump with GC pipes + big baffleplate

    SS   ●2) ●

    PE   ●2) ●

    Pumptype

    Installation type*Pipe

    material

    Pit diameter [mm]

    1200 1400 1600 1800 2000 22003000

    2 pumps3000

    3 pumps

       S   E   1 ,   S   L   1 ,   S   L   V ,   S   E   V

       S  -  p  u  m  p  s ,  r  a  n  g  e  s   5   4 ,   6   6  a  n   d   7   0

    Pump with DC or VC pipes SS   ● ●1)

    Pump with DC or VC pipes + smallscreen basket

    SS   ● ●1)

    Pump with DC or VC pipes + bigscreen basket

    SS   ● ●1)

    Pump with DC or VC pipes + smallbaffle plate

    SS   ● ●1)

    Pump with DC or VC pipes + big

    baffle plate SS  ● ●

    1)

  • 8/19/2019 Statii de pompare prefabricate

    16/44

    P r od uct  r ange

    16

    Pumping station systems5

    Other product variants

    If you cannot find a pumping station that meets your

    requirements, please contact your local Grundfos

    company. We have other ranges of prefabricated

    pumping stations, but they vary from region to region.

    For large prefabricated pumping stations, please see

    Grundfos Product Center at www.Grundfos.com or

    contact your local Grundfos company. We offer a wide

    selection in versions up to 3 metres in diameter and 12

    metres deep in both glass-fibre-reinforced plastic and

    polyethylene. See examples in figures 12 to 14.

    Fig. 12 Custom-made pumping station with separate pits

    Fig. 13 Pumping station with dry-installed pumps,

    including dry and wet chambers (INTEGRA)

    Fig. 14 Pumping station with service cabin

    Fig. 15 Small PUST pumping stations (D400 to 1700, PE)

       T   M   0   6   3   3   0   2   5   1   1   4

       T   M   0   6   3   3   0   3   5   1   1   4

       T   M   0   6   3   3   0   4   5

       1   1   4

       T   M   0   2   9   3   6   3   2   4   0   4

  • 8/19/2019 Statii de pompare prefabricate

    17/44

       C  o  n  s   t  r  u  c   t   i  o  n

    17

    Pumping station systems 6

    6. Construction

    Pumping station

    Fig. 16 Grundfos pumping station

    Components and material specification

       T   M   0   6   3   3   8   2   0   1   1   5

    20

    18

    17

    16

    15

    13

    11

    10

    9

    14

    8

    1

    7

    2 5

    6

    19

    3 4

    12

    Pos. Component Material

    1

    Cover Glass-fibre-reinforced plastic(GRP)

    Cover approved fortraffic

    Concrete ring and cast-iron hatch

    2 Hatch Aluminium

    3 Hatch insulation Styrofoam

    4 Gas springs -

    5 Safety gridGalvanised steel

    Stainless steel

    6 Venting pipe Stainless steel

    7 Handrail Stainless steel

    8 Outlet Stainless steel

    9 Ladders and laddersupports

    Stainless steel

     Aluminium

    10 Service platform Stainless steel

    11 InletStainless steel

    Plastic

    12Screen basket Stainless steel

    Baffle plate Stainless steel

    13Guide pipes for screenbasket

    Stainless steel

    14 PipingStainless steel

    Polyethylene

    15 Lifting chain Stainless steel

    16 Pump -

    17 Auto coupling Epoxy-coated cast iron

    18 Level sensor -

    19 Base plate for pumps Aluminium

    Pos. Component Material

  • 8/19/2019 Statii de pompare prefabricate

    18/44

    C onst  r uct  i  on

    18

    Pumping station systems6

    Valve chamber 

    Fig. 17 Grundfos valve chamber 

    Components and material specification

    The valve chamber always includes a drainage pipe

    leading to the pumping station. The valve chamber is

    also available in a version insulated with PE foam.

       T   M   0   6   3   2   8   8   5   0   1   4

    Pos. Component Material

    1 Valve chamber   Glass-fibre-reinforcedplastic (GRP)2 Cover  

    3Hatch Aluminium

    Hatch insulation Styrofoam

    4 Isolating valve Epoxy-coated cast iron

    5 Non-return valve Epoxy-coated cast iron

    6 Ladders Aluminium

    7 Pipes Stainless steel

    8 Drainage pipe Plastic

    9 Isolating valve Plastic

    1

    2

    3

    4

    5

    7

    6

    8 9

  • 8/19/2019 Statii de pompare prefabricate

    19/44

       C  o  n  s   t  r  u  c   t   i  o  n

    19

    Pumping station systems 6

    Pumping station variants

    Fig. 18 Pumping station with two pumps and goose neck

    outlet

    Fig. 19 Pumping station with two pumps, direct outlet and

    liftable service platform

    Fig. 20 Pumping station (∅3000 mm) with three pumps,

    direct outlet, separate service hatch and fixed

    service platform

    Fig. 21 Pumping station with two pumps, direct outlet and

    separate valve chamber 

       T   M   0   6   1   9   9   0   3   5   1   4

       T   M   0   6   4   0   0   9   1   4   1   5

       T   M   0   6   4   0   1   0   1   4   1   5

       T   M   0   6   2   9   3   2   4   8   1   4

  • 8/19/2019 Statii de pompare prefabricate

    20/44

    C onst  r uct  i  on

    20

    Pumping station systems6

    Covers

     All pumping stations are equipped with a cover that

    can be locked and has a safety grid. The cover type

    depends on the size of the pumping station and the

    installation site.

    Standard covers

    Standard covers are made of fibre-glass-reinforced

    plastic and have an aluminium hatch. The number of

    hatches depends on the pit diameter:

    • one hatch for ∅1200-2200 pits

    • two hatches for ∅3000 pits.

    Note: Aluminium hatches are not approved for traffic.

    Fig. 22  Aluminium hatch and safety grid (∅1200-2200)

    Fig. 23 Service hatches (∅3000)

    Covers approved for traffic

    The covers come in the two versions shown below and

    are approved according to EN 124, Class D.

    Version 1, cover with concrete ring

    The cover has a concrete ring, an extended cover and

    a steel hatch. The cover can be made with (1a) or

    without (1b) a floating cover. See fig. 24.

    Fig. 24 Cover with concrete ring

    For more information about of concrete rings for

    covers approved for traffic, see section Dimensions of

    concrete covers on page 38.

    Version 2, cover with air space

    The cover has a concrete ring and a steel hatch. The

    cover is available for all pit sizes as an optional cover.

    Fig. 25 Cover approved for traffic and with air space

    For more information about of concrete rings for

    covers approved for traffic, see section Dimensions of

    concrete covers on page 38.

       T   M   0   6   1   6   8   5   2   6   1   4

       T   M   0   6   1   6   8   6   2   7   1   4

       T   M   0   6   3   9   1   5   1   2   1   5  -   T   M   0   6   3   9   1   4   1   2   1   5

       T   M   0   6   3   4   5   7   0   4   1   5

    Blacktop

    1a. Concrete ring without blacktop

    1b. Concrete ring with blacktop

    Floating cover 

     Air space between concretering and pit

  • 8/19/2019 Statii de pompare prefabricate

    21/44

       C  o  n  s   t  r  u  c   t   i  o  n

    21

    Pumping station systems 6

    Venting pipes

    Venting pipes can be either top-mounted or side-

    mounted.

    Fig. 26 Pit with top-mounted venting pipe

    Fig. 27 Pit with side-mounted venting pipe

    Control cabinets

    Control cabinets can be installed as follows:

    • on the cover of the pumping station. See fig. 48 on

    page 31.

    • on a separate concrete plate next to pumping

    station

    • on the wall of a building etc.

    Service platforms

    Service platforms enables valve maintenance inside

    the pumping station. The platforms are made of

    aluminium.

    Note: The service platform is for one person only.

    The liftable service platform is equipped with joint

    hinges so that it can be lifted manually, for instance

    when the pump is to be lifted out of the pit. Lifted up,

    the platform rests against the wall and needs no

    locking during the service actions.

    Fig. 28 Liftable service platform

    Fig. 29 Fixed service platform

    Baffle plates

    The baffle plate slows the incoming flow of liquid and

    prevents splattering inside the pit.

    Fig. 30 Baffle plate

       T   M   0   6   1   6   8   3   2   6   1   4

       T   M   0   6   1   6   8   4   2

       6   1   4

    Pit diameter [mm]

    Platform

    1200 Not available

    1400-2200 Liftable

    3000 Fixed installation

       T   M   0   6   3   4   4   6   0   4   1   5

       T   M   0   6   1   6   8   7   2   7   1   4

       T   M   0   6   3   4   4   5   0   4   1   5

    90°

  • 8/19/2019 Statii de pompare prefabricate

    22/44

    C onst  r uct  i  on

    22

    Pumping station systems6

    Screen baskets

    The screen basket removes materials such as stones

    and branches from the incoming flow of liquid.

    Fig. 31 Screen basket

    Level controllers

    Float switches

    Float switches can be installed on a tube outside the

    pumping station. This ensures easy adjustment of the

    float switches. See fig. 32. Two to four float switches

    are used together with LC or LCD controllers.

    Fig. 32  Adjustment of float switches

    Distance B must not be too big as otherwise the float

    switch may get stuck in other parts of the installation.

    Pressure transducers

    If a pressure transducer is used for level detection,

    install it in the protective pipe in order to preventcontamination and deposits.

       T   M   0   6   3   5   1   5   0   6   1   5

    Size

    Basket dimensions

    H x L x W[mm]

    Size of screen holes

    H x L[mm]

    Small 453 x 326 x 206 185 x 45

    Large 794 x 650 x 306 350 x 45

       T   M   0   4   3   4   5   4   4   4   3   8  -   T   M   0   2   8   9   6   0   1   2   0   4

     A Min. 300 mm

    B 50-100 mm

    C Deactivation range: 110 mm

    C

     A

    B

  • 8/19/2019 Statii de pompare prefabricate

    23/44

       A  c  c  e  s  s  o  r   i  e  s

    23

    Pumping station systems 7

    7. Accessories

    Pump controllers

    IO 113 module

    The IO 113 module is a protection module for Grundfos

    wastewater pumps.

    The module has inputs for digital and analog pump

    sensors and can stop the pump if a sensor indicates a

    pump fault.

    The module is connected to the Dedicated Controls

    system and allows advanced monitoring functions:

    • motor temperature

    • moisture in motor 

    • water in oil or water in air 

    • insulation resistance.

    SM 113 module

    The SM 113 module is used for collection and transferof sensor data. The module works together with the IO

    113 through power line communication using the

    Grundfos GENIbus protocol.

    The module can collect data from these devices:

    • 3 current sensors, 4-20 mA

    • 3 PT1000 thermal sensors

    • 1 thermistor circuit (3 sensors in series)

    • 1 digital input.

    Level controllers

    Grundfos offers a wide range of pump controllers to

    keep a watchful eye on liquid levels in the wastewatercollecting pit, ensuring correct operation and

    protection of the pumps.

    Controller ranges:

    • Dedicated Controls: DC and DCD

    • LC and LCD level controllers

    • CU 100 control box.

    The DC, LC and CU 100 are designed for one-pump

    installations, and the DCD and LCD are designed for

    two-pump installations.

    Dedicated Controls

    Grundfos Dedicated Controls is a control system that

    can control and monitor one to six Grundfoswastewater pumps and a mixer or a flush valve.

    Dedicated Controls is used in installations requiring

    advanced control and data communication.

    Main components of the Dedicated Controls system:

    • CU 362 control unit

    • IO 351B module (general I/O module).

    Dedicated Controls is available either as separate

    components or as control cabinets.

    The control system can be operated by the following:

    • f loat switches

    • a level sensor 

    • a level sensor and safety float switches.The control cabinet is available for the following pump

    sizes and starting methods:

    • pumps up to and including 9 kW, direct-on-line

    starting

    • pumps up to and including 30 kW, star-delta starting

    • pumps up to and including 30 kW, soft starter.

    The separate control unit and modules can be built for

    practically any size of system.

    Fig. 33 Dedicated Controls control cabinet

       G  r  -   1   0   1   6   0   8   7

  • 8/19/2019 Statii de pompare prefabricate

    24/44

    Accessor i  es

    24

    Pumping station systems7

    The DC and DCD control cabinets can be fitted with

    various units:

    • The CU 362 control unit, which is the "brain" of the

    Dedicated Controls system, is fitted in the cabinet

    front. The CU 362 can be fitted with one of the

    Grundfos CIM communication modules mentioned

    below, depending on the monitoring needs or the

    SCADA system: – The CIM 200 is a communication module used for

    the Modbus RTU fieldbus protocol.

     – The CIM 250 is a communication module used for

    GSM/GPRS communication. The CIM 250

    establishes communication between the CU 362

    and a SCADA system, thereby allowing the

    application to be monitored and controlled

    remotely. This module also offers SMS

    messaging, for example status and alarm

    messages.

     – The CIM 270 is a communication module for the

    Grundfos Remote Management system (GRM).

    The CIM 270 establishes communication betweenthe CU 362 and the GRM, thereby allowing the

    application to be monitored and controlled

    remotely.

     – The CIM 050 GENIbus module is fit ted in a

    Grundfos product. The CIM 050 enables data

    transmission between a GENIbus network and a

    Grundfos product.

     – The CIM 500 is a Grundfos communication

    interface module used for data transmission

    between an industrial Ethernet network and a

    Grundfos product. The CIM 500 communicates

    with the CIU 902.

    • The IO 351B is a general I/O module andcommunicates with the CU 362 via GENIbus.

    • The MP 204 motor protector (optional), which

    provides many electrical status values, for instance

    voltage, current, power, insulation resistance and

    energy. The MP 204 offers better protection of the

    pumps than a conventional motor protection device.

    • The CUE or VFD (optional) is either a Grundfos

    variable-frequency drive or a general variable-

    frequency drive. The variable-frequency drive offers

    better pump protection and a more steady flow

    through the pit pipes so that the pumps are treated

    well and the energy consumption is kept at a

    minimum.For further information, see the data booklet or

    installation and operating instructions for Dedicated

    Controls in Grundfos Product Center at

    www.Grundfos.com.

    LC and LCD

    The Grundfos LC and LCD ranges of level controllers

    comprise three series with a total of six variants:

    • LC and LCD 107 operated by air bells

    • LC and LCD 108 operated by float switches

    • LC and LCD 110 operated by electrodes.

     All controllers are ideally suited for applications

    requiring up to 11 kW motors for direct-on-line starting.

    Features and benefits

    • Control of one pump (LC) or two pumps (LCD).

    • Automatic alternating operation of two pumps

    (LCD).

    • Automatic test run (prevents shaft seals from

    becoming jammed in the event of long periods of

    inactivity).

    • Water hammer protection.

    • Starting delay after power supply failure.

    • Automatic alarm resetting, if required.

    • Automatic restarting, if required.• Alarm outputs as NO and NC.

    Fig. 34 LCD 110 for two-pump installations

    When an SMS module (optional) is fitted in an LC or

    LCD controller, it acts as a time recorder for the

    pumps, and when programmed (using an ordinary

    mobile phone with text messaging facility), it can send

    text messages containing "high-level alarm", "general

    alarm", information about operation and the number of

    times the pump has started. The SMS module is also

    available with battery and can thus send textmessages that will inform you of power failure and

    when the power has been restored.

    For further information, see the data booklet or

    installation and operating instructions for the LC and

    LCD controllers in Grundfos Product Center at

    www.Grundfos.com.

       T   M   0   4   2   3   6   0   2   4   0

       8

    LCD 110

  • 8/19/2019 Statii de pompare prefabricate

    25/44

       A  c  c  e  s  s  o  r   i  e  s

    25

    Pumping station systems 7

    CU 100

    The CU 100 control box is designed for the starting,

    operation and protection of small wastewater pumps.

    The control box is available in several variants which

    can be used for the following:

    • single-phase pumps (up to and including 9 A)

    • three-phase pumps (up to and including 5 A).

    The control box is also suitable for the following:

    • start/stop by means of a float switch

    • manual start/stop.

    During manual operation, the pump is started and

    stopped with the on/off switch.

    During automatic operation, the float switch will start

    and stop the pump.

    For further information, see the installation and

    operation instructions for the CU 100 in Grundfos

    Product Center at www.Grundfos.com.

    Fig. 35 CU 100

    CUE frequency converter 

    Grundfos CUE is complete range of external frequency

    converters designed for speed control of a wide range

    of Grundfos pumps.

    Fig. 36 CUE

    CUE has a built-in PI controller and offers the same

    functionality and user-interface as Grundfos S-pumps.

    CUE solutions can thus be seen as an extension to the

    S-pump range.

    The CUE offers following benefits:

    • speed control of pumps up to 250 kW (also pumps

    installed in potentially explosive environments)

    • 2 alarm outputs (C, NO, NC)

    • 1 sensor (4-20 mA)

    • 2 PT100 or PT1000 sensors.

       T   M   0   2   6   4   5   9   0   7   0   3

       G  r  -   1   0   1   5   2   2   7

  • 8/19/2019 Statii de pompare prefabricate

    26/44

    Accessor i  es

    26

    Pumping station systems7

    AUTO ADAPT  pumps

    Grundfos CIU

    The Grundfos CIU unit is used as a communication

    interface between a Grundfos product and a main

    network. The CIU unit is used as an interface for

    following:

    • Configuration of pump parameters required forwater level control.

    • Online monitoring of pit and pump values.

    • Manual water level control (forced start/stop).

    • Collection of measured and logged data that are

    valuable for pump service and pit optimisation.

    The CIU unit is designed for use together with

    Grundfos AUTO ADAPT  pumps. Communication can be

    established with the Grundfos GO or by using the main

    network interface of the CIU unit.

     Available CIU units:

    • CIU 152 PROFIBUS DP

    • CIU 902 (without CIM module)• CIU 202 Modbus

    • CIU 252 GSM, GPRS

    • CIU 272 GRM (Grundfos Remote Management).

    The CIU unit incorporates one or two modules:

    • multipurpose I/O module with I/O functionality, IR

    communication interface and power line

    communication.

    • CIM module (optional).

    For further information about the CIM module fitted,

    see the installation and operating instructions for the

    CIM module.

    If a CIM module is fitted in the CIU unit, the sensors

    connected to the digital input of the I/O module can be

    remotely monitored from a centrally located SCADA

    system.

    Grundfos GO

    The Grundfos GO is designed for wireless IR

    communication with Grundfos products. The Grundfos

    GO can communicate with the AUTO ADAPT  pumps viaa CIU unit.

    The Grundfos GO is to be regarded as an ordinary

    service and measuring tool and is therefore designed

    to withstand wear and stress from everyday use.

    ADC

    The ADC fuse box is designed for the protecting the

    power supply for small wastewater pumps.

    Fig. 37  ADC

    The fuse box enables communication with the

    following:

    • Grundfos Remote Management, GRM

    • Grundfos GO

    • SCADA.

    The fuse box can be used with the following:

    • one-pump installation with or without CIU(1

    • two-pump installation with or without CIU(1

    • CIU units

     – CIU 202 Modbus RTU(2

     – CIU 272 GRM(2

     – CIU 902(2

     – CIU 252 GSM complete(2

    • optional service socket 230 V(3 / 50 Hz(2

    • optional socket for PC Tool link box(2

    • optional fault indicator light mounted on top(2

    • optional audio alarm, 100 dB(2.(1 With a CIU unit, a CIM module is needed.(2 Must be ordered with the control box.(3 The modules come as two parts and must be assembled.

    For further information, see the installation and

    operation instructions for the ADC in Grundfos Product

    Center at www.Grundfos.com.

       G  r  -   1   0   1   6   0   1   1

  • 8/19/2019 Statii de pompare prefabricate

    27/44

       A  c  c  e  s  s  o  r   i  e  s

    27

    Pumping station systems 7

    1) If an SMS module is fitted.2) If a CIM 252 GSM/GPRS module is fitted in the CU 362.3) Built-in pressure transducer and dry-running sensor.4) Built-in, but a Grundfos CIU unit is required to get access to data or setting of parameters.5) Modbus, GSM, GPRS, SMS and GRM options.6) When using Grundfos GO.7) Inputs for external sensors (NO or NC).

    Name DC DCD LC LCD CU 100 AUTO ADAPT  CIU

    Application

    One pump   ● ● ● ● ● ● ●

    Two pumps   ● ● ● ●

    Mixer    ● ●

    Backup battery   ● ●

    Level sensor 

    Float switches   ● ● ● ● ●   ● 7)

    Electrodes   ● ●   ● 7)

     Air bells   ● ●   ● 7)

    Pressure transducer    ● ●   ● 3) ● 7)

    Ultrasonic sensor    ● ●   ● 7)

     Analog level sensor with safety floatswitches

    ● ●   ●7)

    Starting method

    Direct-on-line starting (DOL)   ●   ●   ● ● ● ● ●

    Star-delta starting   ●   ●   ● ●

    Soft starter    ●   ●

    Basic functions

    Start and stop of pump(s)   ●   ●   ● ● ● ● ●

    Pump alternation   ● ● ● ●

    High-level alarm   ● ● ● ● ● ●

    Dry-running alarm   ● ● ● ● ● ●

    Flow measurement (calculated or viaflow sensor)

      ● ●

    Pump statistics   ● ●   ● 4) ●

    Conflicting levels alarm   ● ●

    Advanced functions

    Start and stop delays   ● ● ● ● ● ●

    Motor temperature sensor    ● ● ● ●   ● 4) ●

    Test run/anti-seizing   ● ● ● ● ● ●

    Daily emptying (once a day)   ● ● ●

    Water-in-oil sensor input   ● ●

    Communication

    SMS messaging   ● 2) ● 2) ● 1) ● 1) ● 2)

    SCADA communication GSM/GPRS   ● 2) ● 2) ● 5)

    User interface

    Level indication   ● ● ● ●   ● 6)

    Graphical display   ● ●   ● 6)

    PC Tool WW Controls   ● ● ●

  • 8/19/2019 Statii de pompare prefabricate

    28/44

    I  nst  al  l  at  i  on

    28

    Pumping station systems8

    8. Installation

    Local regulations and legal requirements must always

    be observed. For further information, see the

    installation and operating instructions for the pumping

    station.

    Note: Some pits come without the pump installed. For

    installation and startup, see the installation andoperating instructions for the pump.

    Transportation and handling

    The size of the transportation vehicle must be

    calculated in advance to make sure that it is suitable

    for the pit. Use the safety dimensions in the table

    below. The required safety dimensions are based on

    the pit dimensions. See fig. 38.

    Fig. 38 Safety dimensions

    Note: In case of special variants, such as an extra long

    inlet or outlet pipes outside the pit, the size of

    transportation vehicle needs to be redefined.

    The pit must be transported in a horizontal position

    and anchored to the transport vehicle. Accessories, if

    any, must be secured inside the pit.

    Fig. 39 Lifting the pumping station from the lorry

    When lifting the pit, secure the pit with approved

    straps. See fig. 40. The customer must provide the

    appropriate lifting equipment.

    Fig. 40 Lifting straps

    Acceptance inspection

     After transportation and before installation, the

    pumping station must be inspected by the customer.

    The inspection must include the following:

    • Check the pumping station for transport damage.

    Contact the transporter immediately if you detect

    any damage.

    • Check that the products delivered correspond to the

    order.• Check the positions and sizes of fittings.

    • Retighten various connections, as they may have

    become loose during the transport.

    • Check that all valves, except the draining valve in

    the valve chamber, are open.

    • Check other equipment such as venting pipes.

       T   M   0   6   3   5   8   0   0   6   1   5

    Dimension Safety dimensions

     A Pit length plus 400 mm

    B Pit diameter plus 200 mm

    C Pit diameter plus 400 mm

       T   M   0   6

       1   2   3   2   1   9   1   4

     AB

    C

       T   M   0   6   1   2   3   3   1   9   1   4

  • 8/19/2019 Statii de pompare prefabricate

    29/44

       I  n  s   t  a   l   l  a   t   i  o  n

    29

    Pumping station systems 8

    Installation of pumping station

    Fig. 41 Schematic installation drawing

    Installation to excavation holeThe walls of installation excavation hole must be

    secured so that there is no risk of lapse of ground

    during installation. The excavation hole must be

    designed according to local regulations.

    Foundation slab

    The bottom of the excavation hole must be levelled

    and filled with a foundation layer, if needed, before the

    slab is lowered into the excavation hole.

    Fig. 42 Lowering the foundation slab

    For more information about the foundation slab, see

    section Dimensions of the foundation slab on page 35.

    Pumping station

    The surface of the foundation slab must be cleaned

    before the pit is lowered onto it. If a pit is to be installed

    at temperatures below 0 °C, slacken all bolts of the

    flange and retighten them when the pit has been

    installed. In this way, stress in the pipes is prevented.

    Location of inlet

    The inlet can be located 360 ° around the pit, except

    when you have selected a screen basket or baffle

    plate. In these cases the selection tool PUMPING

    STATION CREATOR automatically informs you if the

    inlet is placed in an incorrect position. See page 7.

    In any case, the inlet is designed to be below the

    service platform.

       T   M   0   6   1   8   4   8   3   2   1   4

    Pos. Description

    1 Foundation layer  

    2 Concrete foundation slab

    3 Backf il l, compacted in layers of maximum 50 cm

    4Distance of 50 cm from cover where heavy loads mustnot occur 

    4 4

    3

    2

    1   T   M   0   6   1   2

       3   7   2   5   1   4

  • 8/19/2019 Statii de pompare prefabricate

    30/44

    I  nst  al  l  at  i  on

    30

    Pumping station systems8

    Pit

    When lowering the pit, make sure that the flanges are

    in the right direction according to inlet and outlet pipes.

    The pit is locked to the foundation slab by means of

    mounting brackets and anchor bolts. See section

    Dimensions of the foundation slab on page 35.

    Fig. 43 Installing the pipes and the mounting bracket

    In pits with diameters of 2.0, 2.2 and 3.0 m, discharge

    pipes sizes above DN 150 and with two holes in the

    bottom of the pit, fill the hollow space in the bottom of

    the pit with concrete to avoid vibrations. See fig. 44.

    Fig. 44 How to fill the hollow space with concrete

    Valve chamber 

    The same installation instructions apply to the valve

    chamber as those for the pit.

    Cover approved for traffic

    The maximum angle of inclination for the cover is 25 °.

    The installation method depends on the cover version.

    See the descriptions below.

    Version 1, cover with concrete ring

    The backfill must be compacted carefully so that it

    does not harm the top of the tank. The fraction sizeunder the cover and near the top of the pumping

    station must be between 2 and 20 mm. The cover is

    lowered onto the compacted backfill. A blacktop can be

    made on the ring. See fig. 45.

    Note: The pit comes with a 500 mm collar that must be

    cut to the right length on the installation site.

    Note: The pit must not support the concrete ring.

    Fig. 45 Installation of cover slab with concrete ring

    Dimensions for of the concrete cover slab, see section

    Dimensions of concrete covers on page 40.

    Version 2, cover with air space

    The traffic cover is lowered on the pit when the backfill

    has been compacted to the top of the pit. The air space

    between the cover and pit must be 150 mm. See fig.

    46.

    The backfill for the cover can be made with same

    instructions as those for the pit.

    Fig. 46 Cover with air space

    Dimensions of the concrete cover slab, see sectionDimensions of concrete covers on page 40.

       T   M   0   6   1   2   3   9   1   9   1   4

       T   M   0   6   4   3   5   9   2   1   1   5

       T   M   0   6   3   9   2   1   1   2   1   5

       T   M   0   6   3   5   7   5   0   6   1   5

    350-250 mm

    Fraction size ∅2-20 mm

    Compacted layers

    Blacktop (optional)

    500 mm(factoryheight)

    Thickness of slab: 150-250 mm

    Ground level Concrete slab Cover 

     Air space: 150 mm

    Pit ∅1200-3000

    Compactedlayers

    Top level of the pit

  • 8/19/2019 Statii de pompare prefabricate

    31/44

       I  n  s   t  a   l   l  a   t   i  o  n

    31

    Pumping station systems 8

    Backfill

    The backfill gravel or sand must have an even fraction

    size. The maximum fraction size is 32 mm. The backfill

    material must not contain any stones larger than the

    maximum fraction size.

    When filling a hole in the winter, the filling material

    must be completely melted.

    Carry out backfill layer by layer in such a way that the

    height of a layer never exceeds 50 cm. See fig. 47.

    Note: Compact the backfill under the inlet and outlet

    pipes properly so that they are not exposed to

    downward loads when the backfill settles. Plate

    compactors must not be used at a distance of less than

    30 cm from the pit wall.

    Fig. 47 Compacted layers of maximum 50 cm

    Pump

    See the installation and operation instructions for the

    pump.

    Note: The pump must be lowered carefully into the pit

    in order to avoid damage to pump and pit.

    Installation of level controller 

    See the installation and operating instructions for the

    controller.

    Other accessories

    Not all accessories are factory-fitted and need to be

    installed when the pit has been installed and the

    backfill made. Examples of accessories are venting

    pipe and control panel.

    Electrical installation

    See the installation and operations instructions for the

    pump and the control system.

    Startup

    See the installation and operating instructions for the

    pump and the controller.

    Note: The controller must not be installed in the pit.

    Note: The pump must not run dry; only when checking

    the direction of jerk.

    Control cabinet

    The control cabinet is to be installed on top of the

    pumping station into the raised place that has been

    served for it. Control panels are installed inside the

    cabinet. Make sure that the electrical connection is

    made according the local regulations.

    Fig. 48 Control cabinet

    Commissioning

     A commissioning inspection must be done at the first

    startup. The inspection must include the possible

    failure report that must be delivered to Grundfos.

    The inspection must include the following:

    • wiring connection

    • level controller installation and operation

    • pump installation and operation

    • cable connection

    • necessary adjustments

    • overcurrent relay setting and testing.

    In case of guaranty issues, the commissioning

    inspection report must be available.

    Maintenance

    See the installation and operating instructions for the

    pump and the controller.

    It is important to secure the pumping station cover so

    that unauthorised persons cannot remove it.

       T   M

       0   6   3   3   5   2   5   2   1   4

    Maximum 50 cm   T   M   0   6   3   3   7   6   5   2   1   4

    Silicon sealing

    Washers

    Door is in straight lineand open properly

  • 8/19/2019 Statii de pompare prefabricate

    32/44

    Di  mensi  ons

    32

    Pumping station systems9

    9. Dimensions

    Starting frequency

    In a pumping station, the water volume comprises the

    volume below the lowest pump stop level and the

    pumpable volume above this level, fluctuating with

    pump usage and incoming flow rate. The startingfrequency of the pumps depends on the available

    pumpable volume and the incoming flow rate.

    The starting frequency Z is a function of the ratio

    between Qin/Q and Vh

    Note: When the maximum incoming flow rate is equal

    to the pump capacity, the pump runs permanently.

    When the actual pump capacity for single-pump

    operation is equal to the maximum peak inflow, Zmax,

    will always appear when the inflow is half the pump

    capacity.

    Zmax: maximum number of starts per hour.

    Vh: necessary minimum accumulated volume between

    start and stop.

    Sump volume

    In installations where the expected maximum incoming

    flow rate, Qin, is less than 60 % of the selected pump

    capacity, the accumulated sump volume must be

    chosen in such a way that there will be at least two

    pump starts a day in order to prevent sedimentation in

    the sump.

    Qin = incoming flow rate [l/s]

    Q = pump capacity [l/s]

    Vh =accumulated (pumpable) volume between

    start and stop [m3].

    Zmax =Q x 3.6

    4 x Vh

    Vh =Q x 3.6

    4 x Zmax

  • 8/19/2019 Statii de pompare prefabricate

    33/44

       D   i  m  e  n  s   i  o  n  s

    33

    Pumping station systems 9

    Dimensions of pumping station

    Fig. 49 Dimensional sketch

    * Material and pipe variants, see section Pipes on page 9.** For higher variants (up to 12,000 mm), contact Grundfos.

    Note: Safety dimensions for transportation are shown

    in section Transportation and handling  on page 28.

       T   M   0   6   3   2   3   8   5   0   1   4

       H

     A

    B

    G1

    G

    F

    A[mm]

    B[mm]

    B(cover

    approved fortraffic)

    F[mm]

    G1SS*

    G1PE*

    GSS

    [  mm]

    GPE

    [  mm]

    H**[mm]

    1200 570 x 840

    Manhole

    ∅600/800

    1430DN 50-DN 80 D63-D90 DN 50-DN 300 D63-D315

    1500-8000

    1400 725 x 940 1640

    1600 880 x 1880 1834DN 50-DN 100 D63-D110

    DN 50-DN 400

    D63-D4001800 890 x 1280 2040 DN 50-DN 4502000 1070 x 1400 2263

    DN 65-DN 150 D75-D160DN 50-DN 6002200 1190 x 1400 2468

    3000 1570 x 2200 3285 DN 80-DN 250 D90-D160

  • 8/19/2019 Statii de pompare prefabricate

    34/44

    Di  mensi  ons

    34

    Pumping station systems9

    Dimensions of valve chamber 

    Fig. 50 Dimensional sketch of valve chamber 

    * Low chamber / high chamber.

       T   M   0   6   4   2   8   5   1   8   1   5

    D2

    D1

           H

           H       1

    H*[mm]

    H1*[mm]

    Pipe inlet size[DN]

    D1[mm]

    D2[mm]

    1500 / 2000

    740 ± 50 / 1240 ± 50

    DN 50 1400 1640

    1500 / 2000 DN 65 1400 1640

    1500 / 2000 DN 80 1400 1640

    1500 / 2000 DN 100 1400 1640

    1500 / 2000 DN 150 1400 1640

    1500 / 2000 DN 200 2200 2468

    1500 / 2000 DN 250 2200 2468

  • 8/19/2019 Statii de pompare prefabricate

    35/44

       D   i  m  e  n  s   i  o  n  s

    35

    Pumping station systems 9

    Dimensions of the foundation slab

    Fig. 51 Foundation slab

    Foundation slab

       T   M   0   6   1   9   9   1   3   5   1   4  -   T   M   0   6   3   4   9   8   0   6   1   5

     A

          A

    D

    Go

          A      /      6

     A/6

    D

          B

    600

    B-80mm

    2

    2

    11

    2

    2

    2

    Concrete C40/50-2

    Min. thickness of the concreteon top of the reinforcement

    35 mm

    Concrete exposure class XC4

    Reinforcement B500B

    Max. angle of inclination 25 °

    Max. 25 °

    DimensionPit depth

    Pit diameter [mm]

    [mm] 1000 1200 1400 1600 1800 2000 2200 3000

    A - 1500 1800 2100 2400 2700 3000 3300 4000

    B

    < 3500

    200 200 200 200

    200200

    200 350

    3500-6000

    250

    650

    6000-7000 800

    7000-8000

    250

    900

    8000-9000250 300

    1000

    9000-10,000 1100

    10,000-11,000300 300 350

    1200

    11,000-12,000 1300D - - 1470 1680 1875 2080 2300 2510 3325

  • 8/19/2019 Statii de pompare prefabricate

    36/44

    Di  mensi  ons

    36

    Pumping station systems9

    Anchor bolts

    The number of anchor bolts depends on the pit

    diameter.

    The angle (G°) between the anchoring bolts is

    calculated by dividing the installation circle (360 °) by

    the number of bolts.

    Reinforcement - main bars

    Cells with grey colour shows the minimum amount of

    reinforcement.

    Reinforcement - stirrups

    Pit depthNumber of anchor bolts based on the pit diameter 

    [mm]

    [mm] 1000 1200 1400 1600 1800 2000 2200 3000

    1500 4 4 4 4 4 4 4 6

    2000 4 4 4 4 4 4 4 82500 4 4 4 4 4 4 6 10

    3000 4 4 4 4 4 6 6 12

    3500 4 4 4 4 6 6 8 14

    4000 4 4 4 6 6 8 8 16

    4500 4 4 4 6 6 8 10 16

    5000 4 4 4 6 8 8 10 18

    5500 4 4 6 6 8 10 12 20

    6000 4 4 6 8 8 10 12 22

    6500 4 4 6 8 10 12 14 24

    7000 4 4 6 8 10 12 14 26

    7500 4 6 6 8 10 12 16 28

    8000 4 6 8 10 12 14 16 30

    8500 4 6 8 10 12 14 18 32

    9000 4 6 8 10 12 16 18 32

    9500 4 6 8 10 14 16 20 3410000 4 6 8 12 14 16 20 36

    10500 6 6 10 12 14 18 20 38

    11000 6 8 10 12 14 18 22 40

    11500 6 8 10 12 16 20 22 42

    12,000 6 8 10 14 16 20 24 44

    Pit depth

    Slab width

    [mm]

    [mm] 1500 1800 2100 2400 2700 3000 3300 4000

    < 3500 T8cc200 T8cc200 T8cc200 T8cc200 T8cc200 T8cc200 T10cc300 T12cc250

    3500-6000 T8cc200 T8cc200 T8cc200 T10cc250 T10cc200 T12cc250 T10cc200 T16cc200

    6000-7000 T8cc200 T8cc200 T8cc200 T12cc300 T12cc250 T10cc150 T10cc200 T16cc200

    7000-8000 T8cc200 T8cc200 T10cc250 T12cc300 T10cc150 T12cc250 T10cc150 T16cc150

    8000-9000 T8cc200 T8cc200 T8cc150 T12cc250 T12cc250 T10cc150 T10cc150 T16cc125

    9000-10,000 T8cc200 T10cc250 T12cc300 T10cc150 T12cc250 T12cc200 T10cc150 T16cc125

    10,000-11,000 T8cc200 T10cc250 T12cc250 T12cc300 T12cc300 T10cc150 T10cc150 T16cc100

    11,000-12,000 T8cc200 T10cc250 T12cc250 T12cc250 T12cc250 T10cc150 T10cc150 T16cc100

    Pit depthSlab width

    [mm]

    [mm] 1500 1800 2100 2400 2700 3000 3300 4000

    < 3500 T8cc200 T8cc200 T8cc200 T8cc200 T8cc200 T8cc200 T10cc300 T12cc250

    3500-6000 T8cc200 T8cc200 T8cc200 T10cc250 T10cc200 T12cc250 T10cc200 T16cc200

    6000-7000 T8cc200 T8cc200 T8cc200 T12cc300 T12cc250 T10cc150 T10cc200 T16cc200

    7000-8000 T8cc200 T8cc200 T10cc250 T12cc300 T10cc150 T12cc250 T10cc150 T16cc150

    8000-9000 T8cc200 T8cc200 T8cc150 T12cc250 T12cc250 T10cc150 T10cc150 T16cc125

    9000-10,000 T8cc200 T10cc250 T12cc300 T10cc150 T12cc250 T12cc200 T10cc150 T16cc125

    10,000-11,000 T8cc200 T10cc250 T12cc250 T12cc300 T12cc300 T10cc150 T10cc150 T16cc100

    11,000-12,000 T8cc200 T10cc250 T12cc250 T12cc250 T12cc250 T10cc150 T10cc150 T16cc100

  • 8/19/2019 Statii de pompare prefabricate

    37/44

       D   i  m  e  n  s   i  o  n  s

    37

    Pumping station systems 9

    Lifting

    Slab thicknessDesign weight of the slab

    [kN](load factor 1.25)

    [mm] 1500 1800 2100 2400 2700 3000 3300 4000

    200 14.1 20.3 27.6 36.0 45.6 56.3 68.1 100.0

    250 17.6 25.3 34.5 45.0 57.0 70.3 85.1 125.0

    300 21.1 30.4 41.3 54.0 68.3 84.4 102.1 150.0350 24.6 35.4 48.2 63.0 79.7 98.4 119.1 175.0

    650 45.7 65.8 89.6 117.0 148.1 182.8 221.2 325.0

    800 56.3 81.0 110.3 144.0 182.3 225.0 272.3 400.0

    900 63.3 91.1 124.0 162.0 205.0 253.1 306.3 450.0

    1000 70.3 101.3 137.8 180.0 227.8 281.3 340.3 500.0

    1100 77.3 111.4 151.6 198.0 250.6 309.4 374.3 550.0

    1200 84.4 121.5 165.4 216.0 273.4 337.5 408.4 600.0

    1300 91.4 131.6 179.2 234.0 296.2 365.6 442.4 650.0

    Slab thicknessSlab width

    [mm]

    [mm] 1500 1800 2100 2400 2700 3000 3300 4000

    200 Anchors Rd12 x 70 Rd16 x 80 Rd16 x 80 Rd16 x 80 Rd20 x 127 Rd20 x 127 Rd20 x 127 Rd30 x 170

    Design capacity [kN] 20 43.2 43.2 43.2 80 80 80 138.4

    250 Anchors Rd12 x 70 Rd16 x 80 Rd16 x 80 Rd20 x 127 Rd20 x 127 Rd20 x 127 Rd24 x 140 Rd30 x 170

    Design capacity [kN] 20 43.2 43.2 80 80 80 100 138.4

    300 Anchors Rd16 x 80 Rd16 x 80 Rd16 x 80 Rd20 x 127 Rd20 x 127 Rd24 x 140 Rd30 x 170

    Design capacity [kN] 43.2 43.2 43.2 80 80 100 138.4

    350 Anchors Rd16 x 80 Rd16 x 80 Rd20 x 127 Rd20 x 127 Rd20 x 127 Rd24 x 140 Rd30 x 170

    Design capacity [kN] 43.2 43.2 80 80 80 100 138.4

    650 Anchors Rd20 x 127 Rd20 x 127 Rd24 x 140 Rd20 x 127

    Design capacity [kN] 80 80 100 80

    800 Anchors Rd20 x 127 Rd24 x 140 Rd30 x 170 Rd30 x 170

    Design capacity [kN] 80 100 138.4 138.4

    900 Anchors Rd20 x 127 Rd24 x 140 Rd30 x 170

    Only cast on site

    Design capacity [kN] 80 100 138.4

    1000 Anchors Rd20 x 127 Rd30 x 170 Rd30 x 170

    Design capacity [kN] 80 138.4 138.4

    1100  Anchors Rd20 x 127 Rd30 x 170Design capacity [kN] 80 138.4

    1200 Anchors Rd24 x 140 Rd30 x 170

    Design capacity [kN] 100 138.4

    1300 Anchors Rd24 x 140 Rd30 x 170

    Design capacity [kN] 100 138.4

  • 8/19/2019 Statii de pompare prefabricate

    38/44

    Di  mensi  ons

    38

    Pumping station systems9

    Dimensions of concrete covers

    Version 1, cover with concrete ring

       T   M   0

       6   2   0   4   6   3   4   1   4

    D600/D800E

          B

          C

    220

    D

    FK [kN]3 4 5

    1F

    G

    2

    Lifting anchors

    Pit ∅1200-3000

       T   M   0   6   2   0   4

       5   3   4   1   4

     A

    220

          A

          2      2      0

    E

    3 3

    3 LA

    32

    4

    1

    3

    5

    FK [kN]

    Concrete C40/50-2

    Min. thickness of concrete ontop of the reinforcement

    35 mm

    Concrete exposure class XC4

    Concrete exposure classwithout pavement or covering

    XF4

    Reinforcement B500BMax. angle of inclination 25 °

  • 8/19/2019 Statii de pompare prefabricate

    39/44

       D   i  m  e  n  s   i  o  n  s

    39

    Pumping station systems 9

    Slab dimensions

    Pumping stations, 1000, 1200, 1400 and 1600

    Pumping stations, 1800, 2000 and 2200

    Pumping stations, 3000

    Pit diameter Load FK

    [kN]

    [mm] A15 kN B125 kN C250 kN D400 kN

    1000 2500 x 2500 x 100 2500 x 2500 x 150 2500 x 2500 x 200 2500 x 2500 x 200

    1200 2500 x 2500 x 100 2500 x 2500 x 150 2500 x 2500 x 200 2500 x 2500 x 200

    1400 2500 x 2500 x 100 2500 x 2500 x 150 2500 x 2500 x 200 2500 x 2500 x 200

    1600 2500 x 2500 x 100 2500 x 2500 x 150 2500 x 2500 x 200 2500 x 2500 x 200

    1800 3500 x 3500 x 100 3500 x 3500 x 150 3500 x 3500 x 200 3500 x 3500 x 200

    2000 3500 x 3500 x 100 3500 x 3500 x 150 3500 x 3500 x 200 3500 x 3500 x 200

    2200 3500 x 3500 x 100 3500 x 3500 x 150 3500 x 3500 x 200 3500 x 3500 x 200

    3000 4500 x 4500 x 150 4500 x 4500 x 150 4500 x 4500 x 200 4500 x 4500 x 200

    LoadFK

    [kN]

    Slab dimensions[mm]

    Reinforcement

    A B C D1. Main

    bars2. Opening

    bars x 8E

    [mm]3. Stirrups

    F[mm]

    G[mm]

    4. Topbars

    5. Aroundbars

    Anchorbolts

    Openingdiameter600 mm

     A15 2500 100 50 300 T10cc250 - - T10cc250 400 50 - T10 Rd16 x 80

    B125 2500 150 50 300 T10cc200 T12cc200L1400 400 T10cc200 400 80 - 2T10 Rd16 x 80

    C250 2500 200 50 300 T12cc200 T12cc200L1400 400 T10cc150 600 130 T8cc200 2T12 Rd20 x 127

    D400 2500 200 50 300 T12cc125 T12cc125L1400 500 T10cc125 600 130 T8cc200 3T12 Rd20 x 127

    Openingdiameter800 mm

     A15 2500 100 50 300 T10cc250 - - T10cc250 400 50 - T10 Rd16 x 80

    B125 2500 150 50 300 T10cc200 T12cc200L1600 400 T10cc200 400 80 - 2T10 Rd16 x 80

    C250 2500 200 50 300 T12cc250 T12cc200L1600 400 T10cc150 600 130 T8cc200 2T12 Rd20 x 127

    D400 2500 200 50 300 T12cc125 T12cc125L1600 500 T10cc125 600 130 T8cc200 3T12 Rd20 x 127

    LoadFK

    [kN]

    Slab dimensions[mm]

    Reinforcement

    A B C D1. Main

    bars2. Opening

    bars x 8E

    [mm]3. Stirrups

    F[mm]

    G[mm]

    4. Topbars

    5. Aroundbars

    Anchorbolts

    Openingdiameter600 mm

     A15 3500 100 50 300 T10cc250 T10cc250L1400 500 T10cc250 400 50 - T10 Rd20 x 127

    B125 3500 150 50 300 T10cc175 T12cc175L1600 525 T10cc175 400 80 - 2T10 Rd20 x 127

    C250 3500 200 50 300 T12cc200 T12cc100L1600 500 T10cc200 600 130 T8cc200 2T12 Rd24 x 140

    D400 3500 200 50 300 T12cc125 T16cc125L1800 500 T10cc125 600 130 T8cc200 2T12 Rd24 x 140

    Openingdiameter800 mm

     A15 3500 100 50 300 T10cc250 T10cc250L1400 500 T10cc250 400 50 - T10 Rd20 x 127

    B125 3500 150 50 300 T10cc150 T10cc150L1400 600 T10cc150 400 80 - 2T10 Rd20 x 127

    C250 3500 200 50 300 T12cc175 T12cc175L1600 525 T10cc175 600 130 T8cc200 2T10 Rd24 x 140

    D400 3500 200 50 300 T12cc100 T12cc100L1600 600 T10cc100 600 130 T8cc200 2T12 Rd24 x 140

    LoadFK

    [kN]

    Slab dimensions[mm]

    Reinforcement

    A B C D1. Main

    bars2. Opening

    bars x 8E

    [mm]3. Stirrups

    F[mm]

    G[mm]

    4. Topbars

    5. Aroundbars

    Anchorbolts

    Openingdiameter600 mm

     A15 4500 150 50 300 T10cc250 - - T10cc250 400 80 - T10 Rd30 x 170

    B125 4500 150 50 300 T10cc175 T16cc175L1800 525 T10cc175 400 80 - 2T10 Rd30 x 170

    C250 4500 200 50 300 T10cc200 T16cc100L1800 500 T10cc200 600 130 T8cc200 2T10 Rd30 x 170

    D400 4500 200 50 300 T12cc150 T16cc75L1800 525 T10cc150 600 130 T8cc200 2T12 Rd30 x 170

    Openingdiameter800 mm

     A15 4500 150 50 300 T10cc250 - - T10cc250 400 80 - T10 Rd30 x 170

    B125 4500 150 50 300 T10cc150 T12cc150L1600 600 T10cc150 400 80 - 2T10 Rd30 x 170

    C250 4500 200 50 300 T12cc175 T16cc175L1800 525 T10cc175 600 130 T8cc200 2T10 Rd30 x 170

    D400 4500 200 50 300 T12cc100 T16cc100L1800 600 T10cc100 600 130 T8cc200 2T12 Rd30 x 170

  • 8/19/2019 Statii de pompare prefabricate

    40/44

    Di  mensi  ons

    40

    Pumping station systems9

    Version 2, cover with air space

       T   M   0   6

       3   7   0   7   0   9   1   5

    300

    3

    150

    2T1

    2

    4

    100 T10Max. 25

       2   5   0

       3   0   0

       5   5   0

       1   5   0

       5   0

       1   5   0

       1   0   0 100

    6

    Max. 25

    5

    1

    7

    Pit ∅1000-3000

    800...1500

     A: Width of concrete slab

    Compacted coarse aggregategravel

       T   M   0   6   3   7   0   8   0   9   1   5

     A/5

       A   /   5

       8   0   0

    7 3

    1

    5

    6

    4

    2

    Lifting anchors

    * Without pavement or covering XF4.

    Concrete Reinforcement Lifting

    Strength class C40/50-2 Reinforcement T: B500B Max. angle of inclination 25 °

    Min. thickness of the concrete ontop of the reinforcement

    35 mm

    Exposure classes XF4*

    Water-to-cement ratio   ≤  0.45

    Max. chloride content 0.4 %

    Max. water absorption by mass   ≤   6 %

        H   a    t   c    h

  • 8/19/2019 Statii de pompare prefabricate

    41/44

       D   i  m  e  n  s   i  o  n  s

    41

    Pumping station systems 9

    Slab dimensions

    Pumping stations, 1000, 1200, 1400 and 1600

    Pumping stations, 1800, 2000 and 2200

    Pumping stations, 3000

    Pit diameter Load FK

    [kN]

    [mm] A15 kN B125 kN C250 kN D400 kN

    1000 2500 x 2500 x 400 2500 x 2500 x 400 2500 x 2500 x 500 2500 x 2500 x 500

    1200 2500 x 2500 x 400 2500 x 2500 x 400 2500 x 2500 x 500 2500 x 2500 x 500

    1400 2500 x 2500 x 400 2500 x 2500 x 400 2500 x 2500 x 500 2500 x 2500 x 500

    1600 2500 x 2500 x 400 2500 x 2500 x 400 2500 x 2500 x 500 2500 x 2500 x 500

    1800 3100 x 3100 x 400 3100 x 3100 x 400 3100 x 3100 x 400 3100 x 3100 x 400

    2000 3100 x 3100 x 400 3100 x 3100 x 400 3100 x 3100 x 400 3100 x 3100 x 400

    2200 3100 x 3100 x 400 3100 x 3100 x 400 3100 x 3100 x 400 3100 x 3100 x 400

    3000 3900 x 3900 x 400 3900 x 3900 x 400 3900 x 3900 x 500 3900 x 3900 x 500

    Load FK[kN]

    Slab dimensions[mm]

    Reinforcement

    A B C D1. Main

    bars2. Opening

    bars3. Stirrups

    around4. Opening

    stirrups5. Top bars

    6.Overhangstirrups

    7. Circularstirrups

    Anchorbolts x 4

     A15 2500 400 400 600 T10cc250 - T8cc250 T8cc250 T8cc200 T8cc250 T10cc250 Rd24 x 140

    B125 2500 400 600 800 T10cc250 3T12cc200 T8cc250 T12cc250 T8cc200 T12cc225 T10cc250 Rd24 x 140

    C250 2500 500 800 1000 T12cc250 4T12cc150 T10cc250 T16cc225 T8cc200 T16cc200 T10cc200 Rd24 x 140D400 2500 500 800 1000 T12cc150 3T16cc200 T10cc150 T16cc125 T8cc200 T16cc125 T10cc150 Rd24 x 140

    Load FK[kN]

    Slab dimensions[mm]

    Reinforcement

    A B C D1. Main

    bars2. Opening

    bars3. Stirrups

    around4. Opening

    stirrups5. Top bars

    6.Overhangstirrups

    7. Circularstirrups

    Anchorbolts x 4

     A15 3100 400 400 600 T10cc250 - T8cc250 T8cc250 T8cc200 T8cc250 T10cc250 Rd30 x 170

    B125 3100 400 600 800 T10cc200 3T12cc200 T8cc200 T12cc250 T8cc200 T12cc225 T10cc250 Rd30 x 170

    C250 3100 500 800 1000 T12cc200 4T12cc150 T10cc200 T16cc225 T8cc200 T16cc200 T10cc200 Rd30 x 170

    D400 3100 500 800 1000 T12cc100 3T16cc200 T10cc100 T16cc125 T8cc200 T16cc125 T10cc150 Rd30 x 170

    Load FK[kN]

    Slab dimensions[mm]

    Reinforcement

    A B C D1. Main

    bars2. Opening

    bars3. Stirrups

    around4. Opening

    stirrups5. Top bars

    6.Overhangstirrups

    7. Circularstirrups

    Anchorbolts x 6

     A15 3900 400 400 600 T10cc250 - T8cc250 T8cc250 T8cc200 T8cc250 T10cc250 Rd24 x 140

    B125 3900 400 600 800 T10cc150 3T12cc200 T8cc200 T12cc250 T8cc200 T12cc225 T10cc250 Rd24 x 140

    C250 3900 500 800 1000 T12cc150 4T12cc150 T10cc150 T16cc225 T8cc200 T16cc200 T10cc200 Rd24 x 140

    D400 3900 500 800 1000 T12cc100 3T16cc200 T10cc100 T16cc125 T8cc200 T16cc125 T10cc150 Rd24 x 140

  • 8/19/2019 Statii de pompare prefabricate

    42/44

    Gr und f  osP r od u

    ct  C ent  er 

    42

    Pumping station systems0

    10. Grundfos Product Center 

    All the information you need in one place Downloads

    Performance curves, technical specifications, pictures, dimensional drawings, motorcurves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts.The Product Center displays any recent and saved items - including complete projects -

    right on the main page.

    On the product pages, you can downloadinstallation and operating instructions, databooklets, service instructions, etc. in PDF format.

    "SIZING" enables you tosize a pump based onentered data and selectionchoices.

    Online search and sizing tool to help you

    make the right choice.

    http://product-selection.grundfos.com

    "REPLACEMENT" enables you to find a replacementproduct. Search results will include information on thefollowing:

    • the lowest purchase price• the lowest energy consumption• the lowest total life cycle cost.

    "CATALOGUE" gives youaccess to the Grundfosproduct catalogue.

    "LIQUIDS" enables you to find pumpsdesigned for aggressive, flammableor other special liquids.

  • 8/19/2019 Statii de pompare prefabricate

    43/4443

  • 8/19/2019 Statii de pompare prefabricate

    44/44

    98697625 0615   n  a  m  e   G  r  u  n   d   f  o  s ,

       t   h  e   G  r  u  n   d   f  o  s   l  o  g  o ,  a  n   d   b  e   t   h   i  n   k   i  n  n  o  v  a   t  e

      a  r  e  r  e  g   i  s   t  e  r  e   d   t  r  a   d  e  m  a  r   k  s  o  w  n  e   d   b  y   G  r  u  n   d   f  o  s   H  o   l   d   i  n  g   A   /   S

      o  r   G  r  u  n   d   f  o  s   A   /   S ,

       D  e  n  m  a  r   k .

       A   l   l  r   i  g   h   t  s  r  e  s  e  r  v  e   d  w  o  r   l   d  w   i   d  e .

       ©   C  o  p  y  r   i  g   h   t   G  r  u  n   d   f  o  s   H  o   l   d   i  n  g   A   /   S