SCHEMA AMPLASARE SPATIU COMERCIAL IN ANSAMBLUL … · 2020. 7. 28. · grinzile metalice ale...

1
SPECIFICATIE NUME Proiect nr. Plansa nr. Sef proiect Beneficiar: Tel/fax:0241-660527 E-mail:[email protected] J/13/1777/1996 CUI RO8595273 BD.TOMIS 143A CTA arh. MIHAI ISACOV Proiectat arh. MIHAI ISACOV Desenat Verificat arh. ALINTA ISACOV Faza: SEMNATURA Scara: REV: 0 Format: Data: Titlu plansa: Titlu proiect: Amplasament: DTAC DDN GLOBAL S.R.L. CU SEDIUL IN CONSTANTA, STR. MIRCEA CEL BATRIN NR. 152bis 12/2016 MODERNIZARE SPATIU ADMINISTRATIV SI COMERCIAL DE TIP ALIMENTATIE PUBLICA EXISTENT LA PARTER, ETAJ 1, ETAJ 2 SCHEMA AMPLASARE SPATIU COMERCIAL IN ANSAMBLUL BLOCULUI ST8. SC. 1:500 A-02 OCT'18 N NV SV V S NE SE E SUPRAFETE UTILE PROPUNERE SUPRAFETE PROPUSE DUPA MODERNIZARE LEGENDA P.S.I. LEGENDA INTERVENTII PROPUSE STALPII METALICI PORTANTI DIN ZONA DE NORD-VEST SI AI SCARII S2 VOR FI C0 (CA1) SI PROTEJATI LA FOC 120 MINUTE. GRINZILE METALICE ALE ACOPERISULUI DIN ZONA DE NORD-VEST SI DEASUPRA SCARII S2 C0 (CA1) SI VOR FI PROTEJATE LA FOC 30 MINUTE. ACOPERISURILE AUTOPORTANT (FARA POD) DIN ZONA DE NORD-VEST SI DEASUPRA SCARII S2 VOR FI C0 (CA1) SI PROTEJATE LA FOC 15 MINUTE. SPATIILE COMERCIALE/SERVICII/BIROURI SUNT PREVAZUTE CU: - INSTALATIE DE STINGERE A INCENDIILOR - HIDRANTI DE INCENDIU. - INSTALATIE DE AVERTIZARE DE INCENDIU - INSTALATIE DE AVERTIZARE ANTIEFRACTIE SPATIUL ADMINISTRATIV/BIROURI OPEN-SPACE ESTE DESPARTIT DE RESTUL SPATIILOR (SPATIU COMERCIAL, ZONA ACCES LOCUINTE) CU PERETI CU REZISTENTA LA FOC EI 150. NUMAR PERSOANE ESTIMAT IN SPATIUL ADMINISTRATIV/BIROURI OPEN-SPACE LA ETAJUL 1 = 38 (28 PERMANENTI + 10 VIZITATORI POSIBILI) NUMAR DE FLUXURI DE EVACUARE NECESAR - 1 PENTRU SPATIUL ADMINISTRATIV/BIROURI ((38 pers. de la et. 1) / 80 pers./flux = 0,475). NUMAR DE FLUXURI DE EVACUARE PROPUSE = 2 NUMAR DE CAI DE EVACUARE = 2 SE VOR AMPLASA MINIM 2 STINGATOARE PORTATIVE PF6 UNIFORM REPARTIZATE A 6l CU PULBERE SI BIOXID DE CARBON SAU SPUMA. LEGENDA H arh. ALINTA ISACOV G15 G18 BD. TOMIS NR. 344A, BLOC ST8, CONSTANTA - COMPLEX BOEMA 1:50 1,7 x A1 (841x1010mm) CATEGORIA DE IMPORTANTA: C (NORMALA) CLASA DE IMPORTANTA: III GRADUL DE REZISTENTA LA FOC: II RISC DE INCENDIU: MIC 10 11 12 13 14 10 11 12 13 14 PLAN ETAJ 1 G20 G19 G22 G23 15 15 Ac = 148,14 mp (INCLUSIV PARAPETII) P+4 Bloc de locuinte Bloc de locuinte P+4 BD. TOMIS P S+P+5 S+P+10+NT S+P+6 S+P+8 S+P+4 S+P+5 S+P+2 S+P+5 S+P+2 S+P+7 S+P+10 P+2 P+1 P S+P+9 S+P+8 P S+P+6 P+1 E1 C B A A1 F G H I C.A1 C.A2 C.A3 D.1 D C B B' A D.2 2 3.01 9.01 10 11 12 13 14 15 10 11 12 13 14 15 9 7' 7 6' 8 F G H I 6 1 2 3 4 5 E P+6 Bloc de locuinte Bloc de locuinte P+6 Aleea Orhideelor Ac = 76,59 mp (INCLUSIV PARAPETII) PROPUNERE G15 G21 G14 G16 EI150 EI150 Nr.pers.=3 EI150 Denumire Functiune Supraf_baza [m²] Inaltime [m] Volum [m³] Contur [m] E102 BIROU OPEN- SPACE 244.255 3.830 935.496 121.845 E103 G.S.B. 4.645 3.830 17.791 11.980 E104 G.S.F. 6.745 3.830 25.834 15.740 E105 OFICIU 9.584 3.830 36.705 15.229 E106 CASA SCARII S2 3.356 3.830 12.854 7.917 E101 CASA SCARII S1 13.039 3.830 49.938 16.495 Total 281.624 1078.617 189.206 Geometrie camera dupa Gauss-Elling NOTA: 1. Ghenele verticale pentru conducte si cabluri, la trecerea lor prin plansee vor avea închise spatiile dintre conducte sau cabluri, cu elemente C0 (CA 1), rezistente la foc minimum 30 de minute (EI30). 2. Trapele de vizitare trebuie sa fie C0 sau C1 (CA1 sau CA2a). 3. Pentru usi si ferestre vezi tablourile de tamplarie plansele DA-01 4. Pentru finisajele interioare vezi tablourile de finisaje plansele DA-02 Rmare Inc Rmij Inc Rmic Inc REI60 EI150 EI60-C EI90-C NOTA: Ghenele G15, G8...G13 aferente instalatiilor apartamentelor se vor investiga la momentul decopertarii si se vor reconfigura dupa caz, fara a afecta instalatiile apartamentelor de la etaj. Ghenele G16,G17 aferente etajelor 1 si 2 ale spatiului comercial propus spre modernizare se vor desface si reconfigura conform noilor instalatii propuse. EI150 EI150 EI150 EI150 L=13,05m L=18,10m L=13,80m L=8,35m Nr.pers.=24p+10v Nr.pers.=4p Existent: SUPRAFETE NIVEL ETAJ 1 conform masuratori: Ac = 328,59 mp A nivel etaj 1 = 328,59 mp Au etaj 1 = 284,13 mp Ad = 1122,68 mp REI150 REI150 REI150 REI150 REI150 Rmic Inc Rmij Inc FINISAJE INTERIOARE PROPUSE: SALA MESE, BAR: - PARDOSELI: PIATRA NATURALA/ARTIFICIALA FINISAJ ANTIDERAPANT - PERETI: LAMBRIU, TAPET, VOPSEA LAVABILA - TAVANE: VOPSEA LAVABILA, PLAFON SUSPENDAT GISPCARTON PE SCHELET METALIC SCARI (RAMPE, PODESTE DIN B.A.): - TREPTE, CONTRATREPTE, PODESTE: PIATRA NATURALA/ARTIFICIALA FINISAJ ANTIDERAPANT - PERETI: VOPSEA LAVABILA - TAVANE: VOPSEA LAVABILA - BALUSTRADE METAL ELOXAT BIROURI: - PARDOSELI: COVOR PVC, SCAFE PVC - PERETI: TAPET, VOPSEA LAVABILA - TAVANE: VOPSEA LAVABILA, PLAFON SUSPENDAT GISPCARTON PE SCHELET METALIC GRUPURI SANITARE: - PARDOSELI: GRESIE PORTELANATA ANTIDERAPANTA, PE SUPORT HIDROIZOLAT, CU PANTE 1% SPRE SIFON PARDOSEALA - PERETI: FAIANTA - TAVANE: VOPSEA LAVABILA, PLAFON SUSPENDAT GISPCARTON HIDROFUG PE SCHELET METALIC CAMERA DESEURI: - PARDOSELI: MOZAIC TURNAT CU SCAFE ROTUNJITE - PERETI: FAIANTA CU ROSTURI NIVELATE - DOTARE: ROBINET SI SIFON DE PARDOSEALA (PANTE PARDOSEALA 1% SPRE SIFON) -0.08 +4.00 +3.88 +3.88 +0.08 -0.20 ±0.00 -0.35 +4.00 +3.79 -0.44 +3.79 -1.29 +1.76 -0.08 +3.88 +4.00 +4.00 +4.00 +4.00 +4.00 +4.00 +4.00 +2.434 +2.086 BLOC ST8 - spatii invecinate aferente locuintelor - scara BLOC ST8 - spatii invecinate aferente unui alt spatiu comercial BLOC ST8 - spatii invecinate aferente unui alt spatiu comercial +4.00 +2.087 +0.08 +0.08 5 tr. 30x17 TERASA NECIRCULABILA PESTE PARTER CU TERMO SI HIDROIZOLATIE 12,83 mp TERASA CIRCULABILA DESCOPERITA PESTE PARTER PARTIAL VERDE CU TERMO SI HIDROIZOLATIE 136.93 m² TERASA CIRCULABILA DESCOPERITA PESTE PARTER PARTIAL VERDE CU TERMO SI HIDROIZOLATIE +4.00 +3.83 E103 4.65 m² 11.98 m G.S.B. E105 OFICIU 9.58 m² 15.23 m E101 13.04 m² 16.50 m CASA SCARII S1 BIROU OPEN-SPACE 244.25 m² 121.84 m E102 E104 6.75 m² 15.74 m G.S.F. CASA SCARII S2 E106 3.36 m² 7.92 m 70.04 m² BLOC ST8 - terasa vecina H H Hl = 3.30 Hl = 2.59 Hl = 3.25 Hl = 3.25 Hl = 2.59 Hl = 3.81 Hl = 3.83 Hl = 3.86 +2.36 -0.08 5 tr. 30x17.8

Transcript of SCHEMA AMPLASARE SPATIU COMERCIAL IN ANSAMBLUL … · 2020. 7. 28. · grinzile metalice ale...

Page 1: SCHEMA AMPLASARE SPATIU COMERCIAL IN ANSAMBLUL … · 2020. 7. 28. · grinzile metalice ale acoperisului din zona de nord-vest si deasupra scarii s2 ... scari (rampe, podeste din

SPECIFICATIE NUME

Proiect nr.

Plansa nr.Sef proiect

Beneficiar:

Tel/fax:0241-660527 E-mail:[email protected] J/13/1777/1996 CUI RO8595273 BD.TOMIS 143A CTA

arh. MIHAI ISACOV Proiectat

arh. MIHAI ISACOV Desenat

Verificat arh. ALINTA ISACOV

Faza:SEMNATURAScara:

REV: 0

Format:

Data:

Titlu plansa:

Titlu proiect:

Amplasament:

DTAC

DDN GLOBAL S.R.L.CU SEDIUL IN CONSTANTA, STR. MIRCEA CEL BATRIN NR. 152bis 12/2016

MODERNIZARE SPATIU ADMINISTRATIV SI COMERCIAL DE TIP ALIMENTATIE PUBLICA EXISTENT LA PARTER, ETAJ 1, ETAJ 2

SCHEMA AMPLASARE SPATIU COMERCIAL IN ANSAMBLUL BLOCULUI ST8. SC. 1:500

A-02OCT'18

NNV

SV

V

SNE

SEE

SUPRAFETE UTILE PROPUNERE

SUPRAFETE PROPUSE DUPA MODERNIZARE

LEGENDA P.S.I.

LEGENDA INTERVENTII PROPUSE

STALPII METALICI PORTANTI DIN ZONA DE NORD-VEST SI AI SCARII S2 VOR FI C0 (CA1) SI PROTEJATI LA FOC 120 MINUTE.GRINZILE METALICE ALE ACOPERISULUI DIN ZONA DE NORD-VEST SI DEASUPRA SCARII S2 C0 (CA1) SI VOR FI PROTEJATE LA FOC 30 MINUTE.ACOPERISURILE AUTOPORTANT (FARA POD) DIN ZONA DE NORD-VEST SI DEASUPRA SCARII S2 VOR FI C0 (CA1) SI PROTEJATE LA FOC 15 MINUTE.

SPATIILE COMERCIALE/SERVICII/BIROURI SUNT PREVAZUTE CU:- INSTALATIE DE STINGERE A INCENDIILOR - HIDRANTI DE INCENDIU.- INSTALATIE DE AVERTIZARE DE INCENDIU- INSTALATIE DE AVERTIZARE ANTIEFRACTIE

SPATIUL ADMINISTRATIV/BIROURI OPEN-SPACE ESTE DESPARTIT DE RESTUL SPATIILOR (SPATIU COMERCIAL, ZONA ACCES LOCUINTE) CU PERETI CU REZISTENTA LA FOC EI 150.

NUMAR PERSOANE ESTIMAT IN SPATIUL ADMINISTRATIV/BIROURI OPEN-SPACE LA ETAJUL 1 = 38 (28 PERMANENTI + 10 VIZITATORI POSIBILI)

NUMAR DE FLUXURI DE EVACUARE NECESAR - 1 PENTRU SPATIUL ADMINISTRATIV/BIROURI ((38 pers. de la et. 1) / 80 pers./flux = 0,475).NUMAR DE FLUXURI DE EVACUARE PROPUSE = 2

NUMAR DE CAI DE EVACUARE = 2

SE VOR AMPLASA MINIM 2 STINGATOARE PORTATIVE PF6 UNIFORM REPARTIZATE A 6l CU PULBERE SI BIOXID DE CARBON SAU SPUMA.

LEGENDA

H

arh. ALINTA ISACOV

G15

G18

BD. TOMIS NR. 344A, BLOC ST8, CONSTANTA- COMPLEX BOEMA

1:50

1,7 x A1 (841x1010mm)

CATEGORIA DE IMPORTANTA: C (NORMALA)CLASA DE IMPORTANTA: III GRADUL DE REZISTENTA LA FOC: IIRISC DE INCENDIU: MIC

10 11 12 13 14

10 11 12 13 14

PLAN ETAJ 1

G20

G19

G22

G23

15

15

Ac = 148,14 mp (INCLUSIV PARAPETII)

P+4Bloc de locuinte

Bloc

de lo

cuint

eP+

4

BD. TO

MIS P

S+P+5S+P+10+NT

S+P+6S+P+8

S+P+4

S+P+5

S+P+2

S+P+5S+P+2

S+P+7S+P+10

P+2 P+1

P

S+P+9S+P+8

P

S+P+6

P+1E1

C

B

AA1

F

G

H

I

C.A1

C.A2

C.A3

D.1D

C

BB'

A

D.2

2

3.01

9.01 10 11 12 13 14 15

10 11 12 13 14 1597'76' 8

F

G

H

I

6

1

2

3

4

5

E

P+6Bloc de locuinte

Bloc de locuinte

P+6

Aleea Orhideelor

Ac = 76,59 mp (INCLUSIV PARAPETII)

PROPUNERE

G15

G21

G14

G16

EI15

0

EI15

0

Nr.pers.=3

EI15

0

Denumire Functiune Supraf_baza [m²] Inaltime [m] Volum [m³] Contur [m]

E102BIROU OPEN-SPACE 244.255 3.830 935.496 121.845

E103 G.S.B. 4.645 3.830 17.791 11.980

E104 G.S.F. 6.745 3.830 25.834 15.740

E105 OFICIU 9.584 3.830 36.705 15.229

E106 CASA SCARII S2 3.356 3.830 12.854 7.917

E101 CASA SCARII S1 13.039 3.830 49.938 16.495

Total 281.624 1078.617 189.206

Geometrie camera dupa Gauss-Elling

NOTA:1. Ghenele verticale pentru conducte si cabluri, la trecerea lor prin plansee vor avea închise spatiile dintre conducte sau cabluri, cu elemente C0 (CA 1), rezistente la foc minimum 30 de minute (EI30).2. Trapele de vizitare trebuie sa fie C0 sau C1 (CA1 sau CA2a).3. Pentru usi si ferestre vezi tablourile de tamplarie plansele DA-014. Pentru finisajele interioare vezi tablourile de finisaje plansele DA-02

Rmare IncRmij IncRmic Inc

REI60EI150

EI60-CEI90-C

NOTA: Ghenele G15, G8...G13 aferente instalatiilor apartamentelor se vor investiga la momentul decopertarii si se vor reconfigura dupa caz, fara a afecta instalatiile apartamentelor de la etaj.Ghenele G16,G17 aferente etajelor 1 si 2 ale spatiului comercial propus spre modernizare se vor desface si reconfigura conform noilor instalatii propuse.

EI15

0EI

150

EI150

EI150

L=13

,05m

L=18,10m

L=13,80m

L=8,

35m

Nr.pers.=24p+10v

Nr.pers.=4p

Existent:SUPRAFETE NIVEL ETAJ 1 conform masuratori:Ac = 328,59 mpA nivel etaj 1 = 328,59 mp Au etaj 1 = 284,13 mpAd = 1122,68 mp

REI

150

REI

150

REI

150

REI

150

REI

150

Rmic Inc

Rmij Inc

BLO

C S

T8 -

tera

sa v

ecin

a

FINISAJE INTERIOARE PROPUSE:SALA MESE, BAR:- PARDOSELI: PIATRA NATURALA/ARTIFICIALA FINISAJ ANTIDERAPANT- PERETI: LAMBRIU, TAPET, VOPSEA LAVABILA - TAVANE: VOPSEA LAVABILA, PLAFON SUSPENDATGISPCARTON PE SCHELET METALIC

SCARI (RAMPE, PODESTE DIN B.A.):- TREPTE, CONTRATREPTE, PODESTE: PIATRA NATURALA/ARTIFICIALA FINISAJ ANTIDERAPANT- PERETI: VOPSEA LAVABILA- TAVANE: VOPSEA LAVABILA- BALUSTRADE METAL ELOXAT

BIROURI:- PARDOSELI: COVOR PVC, SCAFE PVC- PERETI: TAPET, VOPSEA LAVABILA- TAVANE: VOPSEA LAVABILA, PLAFON SUSPENDATGISPCARTON PE SCHELET METALIC

GRUPURI SANITARE:- PARDOSELI: GRESIE PORTELANATA ANTIDERAPANTA, PE SUPORT HIDROIZOLAT, CU PANTE 1% SPRE SIFON PARDOSEALA- PERETI: FAIANTA- TAVANE: VOPSEA LAVABILA, PLAFON SUSPENDATGISPCARTON HIDROFUG PE SCHELET METALIC

CAMERA DESEURI:- PARDOSELI: MOZAIC TURNAT CU SCAFE ROTUNJITE- PERETI: FAIANTA CU ROSTURI NIVELATE- DOTARE: ROBINET SI SIFON DE PARDOSEALA(PANTE PARDOSEALA 1% SPRE SIFON)

-0.08

+4.00

+3.88

+3.88

+0.08

-0.20

±0.00 -0.35

+4.00

+3.79

-0.44

+3.79

-1.29 +1.76

-0.08+3.88

+4.00

+4.00

+4.00

+4.00

+4.00

+4.00

+4.00

+2.434+2.086

BLO

C S

T8 -

spat

ii in

veci

nate

afer

ente

locu

inte

lor -

sca

ra

BLO

C S

T8 -

spat

ii in

veci

nate

afer

ente

unu

i alt

spat

iu c

omer

cial

BLO

C S

T8 -

spat

ii in

veci

nate

afer

ente

unu

i alt

spat

iu c

omer

cial

+4.00

+2.087

+0.08

+0.08

5 tr.30x17

TERASA NECIRCULABILA PESTE PARTERCU TERMO SI HIDROIZOLATIE12,83 mp

TERASA CIRCULABILA DESCOPERITA PESTE PARTERPARTIAL VERDE CU TERMO SI HIDROIZOLATIE

136.93 m²

TERASA CIRCULABILA DESCOPERITA PESTE PARTERPARTIAL VERDE CU TERMO SI HIDROIZOLATIE

+4.00

+3.83

E103

4.65 m²11.98 m

G.S.B.

E105OFICIU9.58 m²15.23 m

E101

13.04 m²16.50 m

CASA SCARII S1

BIROU OPEN-SPACE244.25 m²121.84 m

E102

E104

6.75 m²15.74 m

G.S.F.

CASA SCARII S2E106

3.36 m²7.92 m

70.04 m²

BLO

C S

T8 -

tera

sa v

ecin

a

H

H

Hl = 3.30

Hl = 2.59

Hl = 3.25

Hl = 3.25Hl = 2.59

Hl = 3.81Hl = 3.83

Hl = 3.86

+2.36

-0.0

8

5 tr.30x17.8