Proiect Schimbator Caldura (Partea Scrisa)
-
Upload
alex-herzog -
Category
Documents
-
view
215 -
download
0
Transcript of Proiect Schimbator Caldura (Partea Scrisa)
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
1/9
UNIVERSITATEA TEHNICA DE CONSTRUCTII BUCURESTI
FACULTATEA DE INSTALATII
APARATE TERMICE
CALCULUL UNUI SCHIMBATOR DE CALDURA APA-APA
CU PERETI TRANSVERSALI
Herzog Alexandra, anl III, gr!a "
An n#$er%#&ar '(")-'("*
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
2/9
Tema de proiectare
Se va proiecta un schimbator de caldura cu mai multe trecerei, apa-apa, in regim
stationar de functionare pentru preparare de apa calda de incalzire in regim 60/80C,
ce utilizeaza ca agent termic primar apa fierbinte, iar datele de proiectare sunt
urmatoarele:
!"00#"0$!"00#"0%&0!600 '(
t&)!&00#$!&00#&0!&&0C
t&))!*0#0,+$!*0#0,+%&0!*+C
t)!60C
t))!80C
Calculul termic
t1m=t1+ t1
2 =
110+75
2 =92 C
&!.6",. 'g/m"
&!0,6808 (/m
1r&!&,.&
2&!0,"&.8%&0-6m/s
t2m=t2 +t2
2 =
60+802 =70 C
!.**,* 'g/m"
!0,66*6 (/m
1r!,++
2!0,3&+%&0-6m/s
Se presupune valoarea 4iz!0,..*
G1= Q
iz cp1 (t1t1 )
= 60010
3
0,9974,18510
3
35
=4,108 kg/s
G2= Q
cp2 ( t2 t2 )=
600103
4,185103
20=7,168kg/s
Se alege folosirea tevilor la interiorul carora va circula agentul termic primar: 5+,+
7)!&m/s
n1tr'
=
G1
di2
4 1 w '
=
4,108
(20103 )2
4 963,91
=13,56
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
3/9
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
4/9
S0 = Q
k tmc t=
600103
90021,640,7=44,01m2
Se alege ')!.00 (/m valoarea preliminara a coeficientului global de caldura9
tmc=
t1 t2
ln t1
t2
=
3015
ln30
15
=21,64 C
P=t2 t 2
t1 t2 =
8060
11060=0, 4
R=t1 t1
t2 t 2 =
11075
8060=1,75
;
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
5/9
R #1=w1 di
)1=
0,904320103
0,3198106
=56550
R #2=w2 d#
) 2=
0,229125103
0,415106
=13801
* +1=0,0263 R #10,8
P!10,33
0,0263565500,8
1,910,33
=206,3
* +2=C 1 2R #2m
P!20,38(P !2fP!2p )
0,25
0,211,30,6138010,62 2,550,38( 2,552,22 )0,25
=89,24
unde: 1rfla tm!*0C, iar 1rpla t!t&m#tm9/!.0#*09/!8&C
,1=
* +1 -1
di =206,30,6808
20103 =7022./ m
2
/
,2=* +2 - 2
d#=
89,240,6676
25103
=2383./ m2/
k= 1
1
,1+R p1+Rp2+
0
-+1
,2
= 1
1
7022+18105+18105+
2,5103
50 +
1
2383
=1028./m2/
S0= Q
k tmc t=
600103
102821,640,7=38,53m
2
=S0
n dm=
38,53
90 22,5103=6,056m " =6 m
Calculul hidraulic
=imensionare stuturi agent primar:
7s)!&m/s
&=
4G11 ws
= 44,108
963,9 1=0,0736m=73,6mm
se alege =!*6 mm, !",+ mm
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
6/9
ws=4G1
1 & i2=
44,108
963,9 (69103 )2=1,139m /s
=imensionare stuturi agent secundar:
7s)!&m/s
&=
4G22 ws
= 47,168
977,7 1=0,0966m=96,6 mm" s# '$#g# &=102m m 0=4mm
ws= 4G2
2 & i2=
47,168
977,7 (94103 )2=1,056 m /s
Calculul pierderilor de sarcina
1e circuitul agentului termic primar:
1ierderi locale :
>ip rezistenta ?
@m"/'gA
7@m/sA
?7/@$/mA
Colector %& .6",. &,&". &+0,388
intrare#iesire in/din tevi 6%& .6",.0,.03
""63,*&
intoarceri la &80 +% .6",. 0, &.,*8
Bana & .6",. &,&". 6+,3".
robinet trecere%0,
6.6",. &,&". *+0,.6
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
7/9
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
8/9
? pentru trecerea printre tevi asezare esicher9:
?!?0nr#&9!0,"3+&9!3,3+
?0!Cs Ee-0,*!3,3.&"80&-0,*!0,"3"
s2
d =
1
4 (s1
d)2
+
(s2
d)2
=
1
4 (33
25 )2
+(28,58
25)2
=1,32
=
s1
d1
s2
d 1
=
33
251
1,321=1"Cs=3,2+ (4,62,7 )(2s1d)=3,2+(4,62,71 )(2 3325 )=4,492
-
8/12/2019 Proiect Schimbator Caldura (Partea Scrisa)
9/9
iz= Q
Q+Qp=
600103
600103+299,18
=0,999>izp!%p+s=0,997