5
` CALCUL SLU incarcari pe suprafata incarcari pe element Element b h Lungime deschidere perm.norm. UTILA norm. perm.SLU UTILA SLU g M W Rc Mr Verifica? Ri,n (mm) (mm) (m) (m) (daN/m2) (daN/m2) (daN/m) (daN/m) SLU (daNm) (mm3) (N/mm2) (Nm) (N/mm2) caprior c1 100 150 4.4 0.625 50 180 42.1875 168.75 1.5 510.5 375000 13.96 523.6364 verifica 24 caprior 100 150 3.6 0.625 50 200 42.1875 187.5 1.5 372.1 375000 13.96 523.6364 verifica 24 pana 0 0 1.5 0.0 0 13.96 0 u verific 24 dolie/coama 0 0 1.5 0.0 0 13.96 0 u verific 24 CALCUL SLEN incarcari pe suprafata incarcari pe element Element b h Lungime deschidere perm.norm. zapada norm. perm. UTILA SLEN g f1,p fp f2,z fz I f max (mm) (mm) (mm) (m) (daN/m2) (daN/m2) (daN/m) (daN/m) SLEN (mm) (mm) (mm) (mm) (mm3) (mm) caprior c1 100 150 4.4 0.625 50 180 31.25 112.5 1 4.8 7.2 17.3 21.6 28125000 28.8 caprior 100 150 3.6 0.625 50 200 31.25 125 1 2.2 3.2 8.6 10.8 28125000 14.0 pana 0 0 0 0 0 0 0 0 1 #DIV/0! #DIV/0! ### #DIV/0! 0 #DIV/0! dolie/coama 0 0 0 0 0 0 0 0 1 #DIV/0! #DIV/0! ### #DIV/0! 0 #DIV/0!

description

Calcul Elemente Sarpanta Andreea

Transcript of Calcul Elemente Sarpanta Andreea

Page 1: Calcul Elemente Sarpanta Andreea

`

CALCUL SLUincarcari pe suprafata incarcari pe element

Element b h Lungime deschidere perm.norm. UTILA norm. perm.SLU UTILA SLU g M W Rc Mr Verifica? Ri,nm ui m di(mm) (mm) (m) (m) (daN/m2) (daN/m2) (daN/m) (daN/m) SLU (daNm) (mm3) (N/mm2) (Nm) (N/mm2)

caprior c1 100 150 4.4 0.625 50 180 42.1875 168.75 1.5 510.5 375000 13.96 523.6364 verifica 24 1 0.64

caprior 100 150 3.6 0.625 50 200 42.1875 187.5 1.5 372.1 375000 13.96 523.6364 verifica 24 1 0.64

pana 0 0 1.5 0.0 0 13.96 0 nu verifica 24 1 0.64

dolie/coama 0 0 1.5 0.0 0 13.96 0 nu verifica 24 1 0.64

CALCUL SLENincarcari pe suprafata incarcari pe element

Element b h Lungime deschidere perm.norm. zapada norm. perm. UTILA SLEN g f1,p fp f2,z fz I f max f adm Verifica?(mm) (mm) (mm) (m) (daN/m2) (daN/m2) (daN/m) (daN/m) SLEN (mm) (mm) (mm) (mm) (mm3) (mm) (mm)

caprior c1 100 150 4.4 0.625 50 180 31.25 112.5 1 4.8 7.2 17.3 21.6 28125000 28.8 17.6

caprior 100 150 3.6 0.625 50 200 31.25 125 1 2.2 3.2 8.6 10.8 28125000 14.0 14.4 verifica

pana 0 0 0 0 0 0 0 0 1 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 0 #DIV/0! 0 #DIV/0!

dolie/coama 0 0 0 0 0 0 0 0 1 #DIV/0! #DIV/0! #DIV/0! #DIV/0! 0 #DIV/0! 0 #DIV/0!

nu verifica

Page 2: Calcul Elemente Sarpanta Andreea

`

1.1

1.1

1.1

1.1

g i

Page 3: Calcul Elemente Sarpanta Andreea

DETERMINAREA CAPACITATII PORTANTE LA INCOVOIERE NP 005 / 2003

Elementb h Ri,n

m ui m diRi,c W calcul

(mm) (mm) (N/mm2) (N/mm2) (mm3)#REF! #REF! 24 1 0.62 1.1 13.53 #REF!

100 150 24 1 0.62 1.1 13.53 375000

0 0 24 1 0.62 1.1 13.53 0

#REF! #REF! 24 1 0.62 1.1 13.53 #REF!

g i

Page 4: Calcul Elemente Sarpanta Andreea

DETERMINAREA CAPACITATII PORTANTE LA INCOVOIERE NP 005 / 2003

Lemn tratat

m TiVerificare

(Tfm) (Tfm)0.9 #REF! #REF!

0.9 0.46 O.K.

0.9 0.00 nu verifica

0.9 #REF! #REF!

Capacitatea portanta Mr

Moment efectiv

Page 5: Calcul Elemente Sarpanta Andreea

Calcul din vant panou publicitar conform CR 1-1-4/2012

1 Dimensiuni panou b= 4.00 mh= 3.00 mzg= 2.50 m

Ze= 4.00 me= 1.00 m

Zs= 4.00 m

Lungimea de rugozitate, z0, in metri z0= 1.00 m cat IV zone urbanezmin= 10.00 m cat IV zone urbane

2 4.77 kN

2.1 factorul de importanţă – expunere. ᵞIw = 1.00 pentru construcţiile din clasele de importanţă-expunere III şi IV

2.2 Cd = 0.85 Tabel 5.2 Valori ale coeficientului de răspuns dinamic, cd pentru clădiri cu structura metalică

2.3 Cf = 1.80

2.4 Cp(Ze) =Cpq(z) * qm(z)= 0.26 kPa

Cpq(z)=1+7*Iv(z)= 5.28Iv(z)= 0.61β= 2.12 conform tabel 2.3 categoria de teren IV

qm(z)=Cr^2(ze)*qb= 0.05 kPaCr(z)= 0.29

Kr^2(z0)= 0.054 conform tabel 2.2. pentru categoria de teren IV tabel 2.1.qb= 0.60 valoarea de referință a presiunii dinamice a vântului pentru municipiul TULCEA

2.5 Aref = 12.00 mp

Inălţimea de referinţă zs pentru calculul dinamic la vânt al construcţiilor de formaparalelipipedică

Forta globala din vand ce actioneaza perpendicular pe un element de constructie Fw=ᵞiw * Cd * Cf * Cp(Ze) * Aref=

coeficientul de răspuns dinamic al construcţiei (vezi Capitolul 5);

este coeficientul aerodinamic de forţă pentru clădire / structură sau elementstructural, ce include si efectele frecării (vezi Capitolul 4);

Pentru panourile publicitare amplasate la o înălţime zg (măsurată de la suprafaţa terenului)mai mare decât h/4 (vezi Figura 4.21)

valoarea de vârf a presiunii dinamice a vântului evaluată la cota ze;

este aria de referinţă, orientată perpendicular pe direcţia vântului, pentruclădiri / structuri (rel. (3.3)) sau elemente sale (rel. (3.4));