ACOPERIS - Panouri Sandwich

download ACOPERIS - Panouri Sandwich

of 24

  • date post

    09-Feb-2016
  • Category

    Documents

  • view

    113
  • download

    1

Embed Size (px)

Transcript of ACOPERIS - Panouri Sandwich

  • ACOPERI - Panouri sandwich

  • Panouri cu spum poliuretanic

    Panouri cu vat mineral

    Montaj

    Ondatherm 935 IR- cu prindere ascuns

    Referine

    Accesorii pentru finisare

    Transport-Depozitare

    Bonuri de comand

    Referine interior

    Referine exterior

    * ONDATHERM R 1001 2-3

    4-5

    6-7

    8-9

    10-11

    12

    17

    13-16

    18-19

    20-21

    ONDATHERM R 1001 A

    PROMISTYL FEU 3005 T

    pagina

    * Produs n Romnia

    SumarACOPERI - Panouri sandwich

  • Referin: Sala PolivalentArhitect: LEPIC&CHENOT

    ReferineACOPERI - Panouri sandwich

    1

  • 1019 2mm

    22

    38

    40506080

    100

    0.5/0.5

    10.7211.1211.5212.3213.12

    0.6/0.5

    11.0612.0012.4013.2014.00

    0.6/0.6

    12.5512.9513.3514.1514.95

    GREUTATE kg/mpGROSIME PANOU

    (mm)

    B A

    int./ext.

    ONDATHERM R 1001

    Spum poliuretanic fr HCFC

    ACOPERI PENTRU LOCAII CU HIGROMETRIE (UMIDITATE) SCZUT, SAU MEDIE.Not: Pentru locaii cu higrometrie ridicat i foarte ridicat, v rugm s ne consultai.

    CARACTERISTICI GEOMETRICE

    Tipul tablei:- oel laminat galvanizat de grosime 0.5; 0.6 mm.- oel laminat galvanizat prevopsit cu Superpolyester - polyester25 /E acoperire organic, n concordan cu EN 10169.

    - stratul de protecie pentru partea interioar sau exterioara tablei unde se dorete vopsit, conform catalog de culoriRAL, este astfel:

    - galvanizare Z200 (200 g Zn/mp);- vopsire primer 25 m;- vopsire primer 20 m sau 12 m;

    - stratul de protecie pentru partea (interioar sau exterioa-r) opus celei vopsite n gama catalogului de culori RAL,este astfel:

    - galvanizare Z200 (200 g Zn/mp);- vopsire primer 7 m;

    Pentru panourile de acoperi:- faa superioar a panoului este din profil HACIERCO 40, avnd

    5 cute trapezoidale cu nlimea de 40 mm, dispuse la distaneegale de 250 mm;

    - faa superioar a panoului poate fi fabricat astfel nct s iasn afar ntre: min. 50mm i max. 200mm pentru a asigura lun-

    gimea de suprapunere;- faa interioar a panoului este cu profilatur mic, din profil

    KSH 2, cu nervuri cu limea de 41mm/84mm i adncimea de0.50 mm

    - lungimea minim este de 3000mm, iar pentru cele cu suprapu-nere 4000mm cu suprapunerea inclus Tipul termoizolaiei:- densitate 402 kg/mc, conform EN ISO 845 (SR EN 253);- procent de pori nchii: 90-95%;- grosimea stratului de poliuretan: 40mm; 50mm; 60mm; 80mm;100mmTipul de protecie:- folie transparent tip FILM- marginile laterale se acoper cu band autoadeziv.Alte specificaii:- panourile de acoperi se mbin prin suprapunere;- microprofilele mresc rezistena la flambaj local i capacitatea

    portant, mbuntesc aspectul exterior, favorizeaz mbina-rea ntre 2 panouri adiacente;

    Abaterile admise de grosime: pentru panourile de 40mm, o tole-ran de 2mm, iar pentru cele mai mari de 50mm, o tolerande -2mm pn la +3mm.

    ACOPERI - Panouri sandwich

    2

  • Spum poliuretanic fr HCFC

    FILM DE PROTECIEUn film de polietilen cu rol de protecie este aplicat n timpul fabricrii panourilor, att pe partea exterioar ct i pe partea interioa-r a acestora. Filmul de protecie se nltur la montaj dup fixarea panourilor, dar nu mai trziu de 3 luni de la punerea n oper.

    TIERE n msura n care este posibil, trebuie evitat tierea pe antier, pentru a evita riscurile desprinderii spumei de pe tabl. Pentru a evitadeteriorarea panourilor la tiere, se va proteja zona din apropierea tierii. Dup operaiunea de tiere este necesar curarea imedia-t a panourilor.Productorul recomand ca tierea panourilor s NU se realizeze cu discul abraziv.

    PANOTAJnaintea oricrei comenzi trebuie acordat o atenie special panotajului, care va garanta punerea n oper corect i rapid.

    ONDATHERM R 1001 ACOPERI - Panouri sandwich

    Tabel 1 - ncrcri maxime admisibile pentru panouri de acoperi tip ONDATHERM R 1001

    Tabel 2 - ncrcri maxime admisibile pentru panouri de acoperi tip ONDATHERM R 1001

    3

  • coeficietul termic n partea interioar a panoului. coeficientul de pierdere liniar de temperatur corespunztoare captului (mbinrii) panoului este lungimea de suprapunere ntre panourinumrul de fixricoeficientul de pierderi punctuale la nivelul fiecrei fixri aria fiecrui perete

    CARACTERISTICILE PANOURILOR

    DIMENSIUNI

    GREUTATE (kg/m2)

    ACUSTIC

    REACIE LA FOC

    REZISTENA TERMIC

    (exemplu:

    cu = 0.025 W/m.K)

    DENSITATEA TERMOIZOLAIEI

    TIP IZOLAIE TERMIC

    TIP IZOLAIE ACUSTIC

    Grosime nominal a panoului (mm)

    Grosime tabl exterioar (mm)

    Grosime tabl interioar (mm)

    Lime util

    Lime total (de gabarit)

    Lungime maxim de producie

    Suprapunere la capete

    Exemplu grosime 0.63 i 0.63 mm

    Izolare: indice de atenuare fonic (60 mm)

    Absorbie

    Conform Euroclas - EN 13 501 1

    Transmisia termic Uc (W/m2.K)

    Scadere liniar (W/m.K)

    Panourile: B s3,d0 la cerere (echivalen M1)

    Coeficientul de transmisie termic mediu Up trebuie calculat n funcie de regulile normativului Th U, al fasciculelor de perei plini, conform formulei urmtoare:

    Vat de sticl

    *Spum poliuretanic fr HCFC (Hidro Cloro Floro Carbon)

    Lime util: 1000

    ACOPERI PENTRU LOCAII CU HIGROMETRIE (UMIDITATE) SCZUT, SAU MEDIE.

    grosimenominal

    vat de sticl lime total de gabarit: 1080 mm

    Band autoadezivde etanare dinspum PVC

    4 benzi de 120 mm lime perforate, diametrul gurii fiind de 5mm i distana interax de 12.5 mm, suprafaa perforat a benziireprezentnd 15% din suprafaa total a panoului.

    CARACTERISTICI MATERIE PRIM

    Tip de protecieGalvanizat

    Galvanizat-Vopsit

    Calitate oelNORME

    Spum poliuretanic fr HCFC

    ONDATHERM R 1001A ACOPERI - Panouri sandwich

    4

  • (panourile sunt fixate la fiecare cut n dreptul reazemelor)

    2 REAZEME

    PRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNE

    PRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNE

    Grosime nominal a panoului Grosime nominal a panoului DISTANA(m)

    3 REAZEME

    TABEL DE NCRCRIncrcri maxime admisibile [daN/m2], n funcie de reazemele utilizate (pentru grosime tabl de 0.63 0.63 mm).

    FILM DE PROTECIEUn film de polietilen cu rol de protecie este aplicat n timpul fabricrii panourilor, att pe partea exterioar ct i pe partea interioa-r a acestora. Filmul de protecie se nltur la montaj dup fixarea panourilor, dar nu mai trziu de 3 luni de la punerea n oper.

    TIERE n msura n care este posibil, trebuie evitat tierea pe antier, pentru a evita riscurile desprinderii spumei de pe tabl. Pentru a evitadeteriorarea panourilor la tiere, se va proteja zona din apropierea tierii. Dup operaiunea de tiere este necesar curarea imedia-t a panourilor.Productorul recomand ca tierea panourilor s NU se realizeze cu discul abraziv.

    PANOTAJnaintea oricrei comenzi trebuie acordat o atenie special panotajului, care va garanta punerea n oper corect i rapid.

    Spum poliuretanic fr HCFC

    ONDATHERM R 1001A ACOPERI - Panouri sandwich

    5

  • coeficietul termic n partea interioar a panoului. coeficientul de pierdere liniar de temperatur corespunztoare captului (mbinrii) panoului este lungimea de suprapunere ntre panourinumrul de fixricoeficientul de pierderi punctuale la nivelul fiecrei fixri aria fiecrui perete

    FIXARE C

    U

    URUB

    AUTOFORA

    NT

    CU FILET

    DUBLU

    PANOUReacie la foc A2-s1, d0(Echivalen: incombustibil)

    CARACTERISTICI MATERIE PRIM

    Tip de protecie Galvanizat-Vopsit

    Calitate oelNORME

    ACOPERI PENTRU LOCAII CU HIGROMETRIE (UMIDITATE) SCZUT.

    CARACTERISTICILE PANOURILOR

    DIMENSIUNI

    GREUTATE (kg/m2)

    ACUSTIC

    REACIE LA FOC

    REZISTENA TERMIC

    (exemplu:

    cu = 0.025 W/m.K)

    DENSITATEA TERMOIZOLAIEI

    TIP IZOLAIE

    Grosime nominal a panoului (mm)

    Grosime tabl exterioar (mm)

    Grosime tabl interioar (mm)

    Lime util

    Lime total (de gabarit)

    Lungime maxim de producie

    Suprapunere la capete

    Exemplu grosime 0.63 si 0.63 mm

    Izolare: indice de atenuare fonic (60 mm)

    Conform Euroclas - EN 13 501 1

    Transmisia termic Uc (W/m2.K)

    Scadere liniar (W/m.K)

    Panourile: A1 (echivalena: incombustibil)

    Coeficientul de transmisie termic mediu Up trebuie calculat n funcie de regulile normativului Th U, al fasciculelor de perei plini, conform formulei urmtoare:

    Vat mineral bazaltic

    Lime util: 1000

    lime total de gabarit: 1072 mm

    *Acoperire Plastisol pentru suprafeele expuse la foc

    grosimenominal

    band autoadezivde etanare

    band autoadezivde etanare

    Vat mineral bazaltic

    PROMISTYL FEU 3005 T ACOPERI - Panouri sandwich

    6

  • (panourile sunt fixate la fiecare cut n dreptul reazemelor)

    2 REAZEME

    PRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNE

    PRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNEPRESIUNE SUCTIUNE