Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE...

10
Uscatoarele orizontale de cereale GSI Continut Descrierea uscatoarelor orizontale ............................................................................................................................... 2 Seria 1100 ...................................................................................................................................................................... 6 Seria 1200 ...................................................................................................................................................................... 7 Seria 1200S .................................................................................................................................................................... 8 Seria 2000 ...................................................................................................................................................................... 9 Seria 3000 .................................................................................................................................................................... 10 MG TRADE ENGINEERING S.R.L., Strada Miletin 56, Corp 2 Parter, Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86, [email protected], www.mgtrade.ro

Transcript of Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE...

Page 1: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

Continut

Descrierea uscatoarelor orizontale ............................................................................................................................... 2

Seria 1100 ...................................................................................................................................................................... 6

Seria 1200 ...................................................................................................................................................................... 7

Seria 1200S .................................................................................................................................................................... 8

Seria 2000 ...................................................................................................................................................................... 9

Seria 3000 .................................................................................................................................................................... 10

MG TRADE ENGINEERING S.R.L., Strada Miletin 56, Corp 2 Parter, Bucuresti, Romania

Fix: 021 323.77.90, Fax: 021 323.26.86, [email protected], www.mgtrade.ro

Page 2: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

2/10

Descrierea uscatoarelor orizontale

In uscatoarele orizontale GSI, cerealele curg printr-un buncar cu doi pereti perforati si sunt uscate de aerul cald

care trece dinspre peretele interior spre cel exterior. Deoarece uscarea se poate realiza la mai putin de 99 °C, riscul

de degradare a boabelor (e.g., crapare, reducerea valorilor nutritive) este foarte redus. Printre echipamentele

optionale disponbile pentru acest tip de uscatoare se gasesc: recuperatorul de caldura, sistemul de reducere a

zgomotului si platforma cu roti care permite transportul utilajului pe sosea.

Principiul de functionare

Uscatoarele orizontale sunt compuse din unul pana la trei module

puse unul peste altul. Fiecare modul este alcatuit dintr-o camera

de ardere, una sau doua perechi ventilator + arzator, un buncar cu

pereti perforati si echipamentele de control si siguranta.

Produsul intra prin gura de alimentare din partea superioara a

uscatorului si este distribuit de un transportor elicoidal pe toata

lungimea buncarului. Aerul atmosferic este incalzit de arzator si

ajunge in camera de ardere. De aici, curentul trece prin peretele

perforat interior, apoi prin masa de cereale si iese prin peretele

perforat exterior. In continuare, in functie de model si de modul

de uscare, cerealele pot fi racite in mod asemanator, cu un curent

de aer la temperatura atmosferica. Produsul este evacuat cu

transportorul elicoidal de descarcare din partea inferioara a

uscatorul, procesul fiind controlat prin intermediul rolelor de

dozare.

In imaginea alaturata este prezentat un uscator cu trei module si

sase agregate de uscare – racire. In acest exemplu, primele patru

agregate functioneaza in modul de uscare, avand atat ventilatorul

cat si arzatorul pornite. Cele doua agregate de la baza sunt in

modul racire, avand numai ventilatorul in functiune.

1. Transportor elicoidal pentru incarcare

2. Buncar de preuscare

3. Plan de separatie intre camerele unui modul

4. Camera de incalzire

5. Reazem de buncar

6. Buncar (coloana) cu pereti perforati

7. Aer cald saturat rezultat prin incalzirea cerealelor

8. Ventilator cu arzator

9. Aer incalzit sub presiune

10. Montant

11. Aer cald nesaturat rezultat prin racirea cerealelor

12. Aer atmosferic sub presiune

13. Role de dozare

14. Transportor elicoidal pentru evacuare

15. Picioare de sustinere

Page 3: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

3/10

Uscatoarele orizontale GSI au doua moduri de utilizare:

Flux continuu: Incarcarea si descarcarea cerealelor se realizeaza in mod continuu.

Sarja programata: Incarcarea si descarea sunt facute pe portiuni din uscator.

Modulele unui uscator orizontal

Un modul al unui uscator orizontal contine

unul sau doua agregate de uscare formate

dintr-un ventilator si un arzator.

Uscatoarele GSI orizontale sunt proiectate

pentru a fi extinse prin adaugarea de module.

Se poate porni cu un modul de baza care

contine sistemele de control. Dupa aceea,

capacitatea de uscare poate fi crescuta prin

adaugarea a unul sau doua module.

Dispozitivele si agregatele de uscare din

aceste module sunt controlate folosind

panoul modulului de la baza. Astfel, clientul

beneficiaza de un grad mare de flexibilitate

pentru realizarea achizitiei, aceasta putand fi

facuta in etape.

In imaginea din dreapta este prezentat un uscator cu un singur modul si doua agregate de uscare.

Modele

1 m

od

ul Seria 1100

1 ventilator 1 arzator

Seria 1200 2 ventilatoare 2 arzatoare

Seria 1200S 2 ventilatoare 2 arzatoare

2 m

od

ule

Seria 2300 3 ventilatoare 3 arzatoare

Seria 2400 4 ventilatoare 4 arzatoare

3 m

od

ule

Seria 3400 4 ventilatoare 4 arzatoare

Seria 3600 6 ventilatoare 6 arzatoare

Fiecare camera de ardere este echipata cu limitatoare de temperatura si senzori de presiune a aerului. De

asemenea, sunt monitorizate urmatoarele componente: limitatorul de temperatura din carcasa ventilatorului /

arzatorului, cel de la vaporizator, traductorul de turatie a rolelor de descarcare si senzorul de flacara. Uscatorul

este echipat cu un intrerupator de oprire de siguranta la snecul de descarcare.

Page 4: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

4/10

Dotari

Seria 1100 1200 1200S 2300 2400 3400 3600

Platforma de transport cu roti O O N/A N/A N/A N/A N/A

Suporti O O O S S S S

Reductor de zgomot O O O O O O O

Recuperator de caldura N/A O O O O O O

Sistem de control Vision S S S S S S S

Configuratie X-Stream N/A N/A O* O* O* O* O*

Set de invertoare de cereale O N/A O O O O O

S: Standard N/A: Nedisponibil / Nu se aplica O: Optional *: Doar modele **20, **22, **26 pot fi configurate in forma X-Stream

Platforma de transport cu roti

Uscatoarele orizontale GSI cu un singur modul (seriile 1100, 1200 si 1200S) pot fi

asezate pe o platforma de transport cu roti. Prin folosirea acestui accesoriu

optional, clientul are posibilitatea de a face uscarea cu un singur utilaj in mai

multe baze de depozitare sau chiar pe camp. Pentru a functiona, uscatorul are

nevoie doar de acces la o sursa de combustibil si la una de curent electric.

Uscatorul poate ramane permanent pe platforma mobila, nefiind nevoie de alte

elemente de suport in timpul utilizarii. Platforma mobila se ataseaza la vehicul ca o remorca normala. In plus,

datorita greutatii reduse, utilajul poate fi transportat cu o masina de teren.

Sistemul de reducere a zgomotului

Ansamblul optional pentru reducerea zgomotului este construit din componente

perforate si galvanizate. Zgomotul este redus pana la un nivel mai mic decat cel

creat de un ventilator centrifugal. In functie de distanta, se poate ajunge la un

nivel de doar 15% din zgomotul fara amortizor. Astfel, uscatorul poate fi utilizat

in zone in care este necesara operare la un nivel foarte scazut de poluare fonica.

Recuperatorul de caldura

Recuperatorul de caldura se poate instala pe uscatoarele orizontale pentru a

reduce consumul cu pana la 30%, cand se opereaza in modul Dry & Cool.

Conductele de aer sunt proiectate sa nu retina praful, astfel incat ele nu introduc

pierderi de capacitate. Deoarece sunt dimensionate pentru o viteza mica a

aerului, particulele fine din atmosfera nu sunt trase in uscator. Recuperatorul de

caldura poate fi folosit impreuna cu reductorul de zgomot.

Sistem de control Vision

Sistemul Vision este conceput pentru controlul uscatoarelor GSI. Accesul la

sistem se face printr-un panou cu ecran tactil, care poate fi amplasat pana la o

distanta de 300 m de uscator. Sistemul are la baza un circuit electric cu tensiune

Page 5: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

5/10

scazuta, iar pe fiecare uscator se afla o siguranta pentru deconectare. Fiecare siguranta este monitorizata separat si

starea ei este afisata pe ecran.

Configuratia X-Stream

Uscatoarele orizontale din seria X-Stream au perechile ventilator + arzator la

capete opuse. Deoarece ansamblurile ventilator + arzator sunt montate in zig-

zag, sistemul X-Stream distribuie uniform aerul cald prin camerele de uscare.

Pentru ca boabele sunt expuse in mod similar caldurii, uscarea se face la acelasi

grad, iar costurile sunt mai mici.

Invertoarele de cereale

Invertoarele de cereale

ajuta la realizarea unei

uscari mai bune si la

reducerea costurilor de operare. In trecut, uscatoarele

puteau fi echipate cu dispozitive care muta produsul de la

interiorul camerei de incalzire catre exteriorul acesteia.

Procesul de inversare al locului boabelor ajuta la pastrarea

unei temparaturi optime de uscare. Astfel, se

maximizeaza calitatea produsului, iar cantitatea de

carburant consumata este mult diminuata.

Page 6: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

6/10

Seria 1100

Model 1108 1112 1114 1116 1118 1120 1122 1126

Moduri de functionare

Flux continuu – uscare cu racire inclusa Nu Nu Nu Nu Nu Nu Nu Nu

Flux continuu – uscare fara racire Da Da Da Da Da Da Da Da

Sarja – uscare cu racire inclusa Da Da Da Da Da Da Da Da

Sarja – uscare fara racire Da Da Da Da Da Da Da Da

Capacitate uscare in sarja1

Uscare cu racire de la 25% la 15% (t/h) 3.75 4.99 5.9 6.36 7.26 8.17 8.85 10.33

Uscare cu racire de la 20% la 15% (t/h) 4.99 6.58 7.72 8.4 9.76 10.78 11.8 13.73

Capacitate uscare in flux continuu1

Uscare fara racire de la 30% la 15% (t/h) 4.23 5.4 6.26 7.15 8.28 9.25 10.07 11.77

Uscare fara racire de la 25% la 15% (t/h) 5.93 7.58 8.81 10.04 11.65 13.01 14.14 16.55

Uscare fara racire de la 20% la 15% (t/h) 9.96 12.74 14.79 16.86 19.57 21.86 23.79 27.82

Capacitatea si dimensiunile buncarului

Grosimea stratului de produs (cm) 35.56 35.56 35.56 35.56 35.56 35.56 35.56 35.56

Lungimea buncarului (m) 2.438 3.658 4.267 4.877 5.486 6.096 6.705 7.925

Capacitatea buncarului cu zona de preuscare (t) 6.05 8.31 9.68 11.07 12.45 13.82 15.22 17.98

Capacitatea buncarului fara zona de preuscare (t) 5.08 7.16 8.36 9.55 10.74 11.94 13.13 15.52

Incarcarea si descarcarea uscatorului

Snecul de incarcare (kW) 1.491 1.491 2.237 3.728 3.728 5.593 5.593 7.457

Capacitate (t/h) 96.52 96.52 96.52 96.52 96.52 96.52 96.52 96.52

Snecul de descarcare (kW) 1.119 1.119 2.237 3.728 3.728 5.593 5.593 7.457

Ansamblul de variatie continua a debitului

Motorul variatorului de debit (kW) 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25

Capacitate maxima la descarcare (t/h) 28.58 42.67 49.79 56.9 64.01 71.12 78.24 92.46

Dimensiuni de gabarit

Lungime (m) 4.623 5.842 6.451 7.061 7.671 8.28 8.89 10.11

Latime (m) 2.438 2.438 2.438 2.438 2.438 2.438 2.438 2.438

Inaltime (fara suporti de fundatie) (m) 4.42 4.42 4.42 4.42 4.42 4.42 4.42 4.42

Ventilatoare si arzatoare

Modul 1 - Ventilator 1 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

1.016 m 11.185 kW /

1.016 m 14.914 kW /

1.067 m 18.642 kW /

1.067 m 22.371 kW /

1.067 m 29.828 kW /

1.067 m

Modul 1 - Ventilator 2

Modul 1 - Arzator 1 (kW) 1026 1319 1685 1685 1978 2198 2564 3004

Modul 1 - Arzator 2 (kW)

Modul 2 - Ventilator 1

Modul 2 - Ventilator 2

Modul 2 - Arzator 1 (kW)

Modul 2 - Arzator 2 (kW)

Modul 3 - Ventilator 1

Modul 3 - Ventilator 2

Modul 3 - Arzator 1 (kW)

Modul 3 - Arzator 2 (kW)

Incarcari electrice

Trifazice / 380 V (A) 31 31 33.8 41.2 48.2 64.4 71.4 89

1 Capacitatea variaza in functie de parametri ca temperatura exterioara, umiditatea atmosferica si calitatea produsului. Valorile specificate sunt aproximative si sunt obtinute in urma unor simulari si reprezinta tone de porumb umed la intrare. In cazul uscarii fara racire, umiditatea de 15% este atinsa dupa racirea produsului in siloz.

Page 7: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

7/10

Seria 1200

Model 1214 1216 1218 1220 1222 1226

Moduri de functionare

Flux continuu – uscare cu racire inclusa Da Da Da Da Da Da

Flux continuu – uscare fara racire Da Da Da Da Da Da

Sarja – uscare cu racire inclusa Da Da Da Da Da Da

Sarja – uscare fara racire Da Da Da Da Da Da

Capacitate uscare in flux continuu1

Uscare cu racire de la 25% la 15% (t/h) 5.9 6.92 7.51 8.33 9.51 10.83

Uscare cu racire de la 20% la 15% (t/h) 9.94 11.63 12.67 13.99 16.02 18.21

Uscare fara racire de la 30% la 15% (t/h) 6.84 7.83 8.43 9.67 10.69 12.02

Uscare fara racire de la 25% la 15% (t/h) 9.6 11.03 11.87 13.6 15.03 16.89

Uscare fara racire de la 20% la 15% (t/h) 16.19 18.53 19.98 22.85 25.28 28.37

Capacitatea si dimensiunile buncarului

Grosimea stratului de produs (cm) 35.56 35.56 35.56 35.56 35.56 35.56

Lungimea buncarului (m) 4.267 4.877 5.486 6.096 6.705 7.925

Capacitatea buncarului cu zona de preuscare (t) 9.68 11.07 12.45 13.82 15.22 17.98

Capacitatea buncarului fara zona de preuscare (t) 8.36 9.55 10.74 11.94 13.13 15.52

Incarcarea si descarcarea uscatorului

Snecul de incarcare (kW) 3.728 3.728 3.728 5.593 5.593 7.457

Capacitate (t/h) 96.52 96.52 96.52 96.52 96.52 96.52

Snecul de descarcare (kW) 3.728 3.728 3.728 5.593 5.593 7.457

Ansamblul de variatie continua a debitului

Motorul variatorului de debit (kW) 0.25 0.25 0.25 0.25 0.25 0.25

Capacitate maxima la descarcare (t/h) 49.79 56.9 64.01 71.12 78.24 92.46

Dimensiuni de gabarit

Lungime (m) 6.451 7.061 7.671 8.28 8.89 10.11

Latime (m) 2.438 2.438 2.438 2.438 2.438 2.438

Inaltime (fara suporti de fundatie) (m) 4.42 4.42 4.42 4.42 4.42 4.42

Ventilatoare si arzatoare

Modul 1 - Ventilator 1 11.185 kW /

0.711 m 11.185 kW /

0.711 m 11.185 kW /

0.711 m 11.185 kW /

0.711 m 11.185 kW /

0.711 m 11.185 kW /

0.711 m

Modul 1 - Ventilator 2 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

1.016 m 14.914 kW /

1.067 m 18.642 kW /

1.067 m

Modul 1 - Arzator 1 (kW) 879 879 879 879 879 879

Modul 1 - Arzator 2 (kW) 1319 1319 1319 1612 1978 2198

Modul 2 - Ventilator 1

Modul 2 - Ventilator 2

Modul 2 - Arzator 1 (kW)

Modul 2 - Arzator 2 (kW)

Modul 3 - Ventilator 1

Modul 3 - Ventilator 2

Modul 3 - Arzator 1 (kW)

Modul 3 - Arzator 2 (kW)

Incarcari electrice

Trifazice / 380 V (A) 66.2 66.2 66.2 75.4 82.4 95

1Capacitatea variaza in functie de parametri ca temperatura exterioara, umiditatea atmosferica si calitatea produsului. Valorile specificate sunt aproximative si sunt obtinute in urma unor simulari si reprezinta tone de porumb umed la intrare. In cazul uscarii fara racire, umiditatea de 15% este atinsa dupa racirea produsului in siloz.

Page 8: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

8/10

Seria 1200S

Model 1214S 1218S 1220S 1222S 1226S

Moduri de functionare

Flux continuu – uscare cu racire inclusa Da Da Da Da Da

Flux continuu – uscare fara racire Da Da Da Da Da

Sarja – uscare cu racire inclusa Da Da Da Da Da

Sarja – uscare fara racire Da Da Da Da Da

Capacitate uscare in flux continuu1

Uscare cu racire de la 25% la 15% (t/h) 5.22 6.24 6.99 7.81 9.72

Uscare cu racire de la 20% la 15% (t/h) 8.78 10.49 11.77 13.12 16.31

Uscare fara racire de la 30% la 15% (t/h) 6.57 8.68 9.98 10.82 13.21

Uscare fara racire de la 25% la 15% (t/h) 9.24 12.19 14.03 15.21 18.55

Uscare fara racire de la 20% la 15% (t/h) 15.54 20.51 23.59 25.55 31.19

Capacitatea si dimensiunile buncarului

Grosimea stratului de produs (cm) 35.56 35.56 35.56 35.56 35.56

Lungimea buncarului (m) 4.267 5.486 6.096 6.705 7.925

Capacitatea buncarului cu zona de preuscare (t) 9.68 12.45 13.82 15.22 17.98

Capacitatea buncarului fara zona de preuscare (t) 8.36 10.74 11.94 13.13 15.52

Incarcarea si descarcarea uscatorului

Snecul de incarcare (kW) 3.728 3.728 5.593 5.593 7.457

Capacitate (t/h) 96.52 96.52 96.52 96.52 96.52

Snecul de descarcare (kW) 3.728 3.728 5.593 5.593 7.457

Ansamblul de variatie continua a debitului

Motorul variatorului de debit (kW) 0.25 0.25 0.25 0.25 0.25

Capacitate maxima la descarcare (t/h) 49.79 64.01 71.12 78.24 92.46

Dimensiuni de gabarit

Lungime (m) 6.451 7.671 8.28 8.89 10.11

Latime (m) 2.642 2.642 2.642 2.642 2.642

Inaltime (fara suporti de fundatie) (m) 4.42 4.42 4.42 4.42 4.42

Ventilatoare si arzatoare

Modul 1 - Ventilator 1 11.185 kW /

0.711 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 1 - Ventilator 2 11.185 kW /

0.711 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 1 - Arzator 1 (kW) 1026 1319 1319 1319 1978

Modul 1 - Arzator 2 (kW) 1026 1319 1319 1319 1978

Modul 2 - Ventilator 1

Modul 2 - Ventilator 2

Modul 2 - Arzator 1 (kW)

Modul 2 - Arzator 2 (kW)

Modul 3 - Ventilator 1

Modul 3 - Ventilator 2

Modul 3 - Arzator 1 (kW)

Modul 3 - Arzator 2 (kW)

Incarcari electrice

Trifazice / 380 V (A) 66.2 66.2 75.4 75.4 109

1 Capacitatea variaza in functie de parametri ca temperatura exterioara, umiditatea atmosferica si calitatea produsului. Valorile specificate sunt aproximative si sunt obtinute in urma unor simulari si reprezinta tone de porumb umed la intrare. In cazul uscarii fara racire, umiditatea de 15% este atinsa dupa racirea produsului in siloz.

Page 9: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

9/10

Seria 2000

Model 2314 2318 2320 2322 2326 2420 2426

Moduri de functionare

Flux continuu – uscare cu racire inclusa Da Da Da Da Da Da Da

Flux continuu – uscare fara racire Da Da Da Da Da Da Da

Sarja – uscare cu racire inclusa Da Da Da Da Da Da Da

Sarja – uscare fara racire Da Da Da Da Da Da Da

Capacitate uscare in flux continuu1

Uscare cu racire de la 25% la 15% (t/h) 14.53 18 19.96 21.91 26.38 19.98 26.22

Uscare cu racire de la 20% la 15% (t/h) 24.41 30.28 33.53 36.84 44.34 33.63 44.12

Uscare fara racire de la 30% la 15% (t/h) 14.72 18.15 20.18 22 27 20.18 27.02

Uscare fara racire de la 25% la 15% (t/h) 20.71 25.47 28.36 30.9 37.94 28.33 37.98

Uscare fara racire de la 20% la 15% (t/h) 34.79 42.85 47.67 51.94 63.74 47.62 63.81

Capacitatea si dimensiunile buncarului

Grosimea stratului de produs (cm) 35.56 35.56 35.56 35.56 35.56 35.56 35.56

Lungimea buncarului (m) 4.267 5.486 6.096 6.705 7.925 6.096 7.925

Capacitatea buncarului cu zona de preuscare (t) 18.57 23.88 26.52 29.19 33.12 26.52 33.12

Capacitatea buncarului fara zona de preuscare (t) 17.25 22.18 24.64 27.1 32.03 24.64 32.03

Incarcarea si descarcarea uscatorului

Snecul de incarcare (kW) 3.728 3.728 5.593 5.593 7.457 5.6 7.5

Capacitate (t/h) 96.52 96.52 96.52 96.52 96.52 96.52 96.52

Snecul de descarcare (kW) 3.728 3.728 5.593 5.593 7.457 5.6 7.5

Ansamblul de variatie continua a debitului

Motorul variatorului de debit (kW) 0.25 0.25 0.25 0.25 0.25 0.25 0.25

Capacitate maxima la descarcare (t/h) 49.79 64.01 71.12 78.24 92.46 71.12 92.46

Dimensiuni de gabarit

Lungime (m) 7.264 8.484 9.093 9.702 10.922 9.093 10.922

Latime (m) 2.642 2.642 2.642 2.642 2.642 2.642 2.642

Inaltime (fara suporti de fundatie) (m) 7.899 7.899 7.899 7.899 7.899 7.899 7.899

Ventilatoare si arzatoare

Modul 1 - Ventilator 1 11.185 kW /

0.711 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m 11.2 kW / 0.914 m

18.6 kW / 1.016 m

Modul 1 - Ventilator 2 11.185 kW /

0.711 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m 11.2 kW / 0.914 m

18.6 kW / 1.016 m

Modul 1 - Arzator 1 (kW) 1026 1319 1319 1319 1978 1319 1978

Modul 1 - Arzator 2 (kW) 1026 1319 1319 1319 1978 1319 1978

Modul 2 - Ventilator 1 11.185 kW /

1.016 m 14.914 kW /

1.067 m 18.642 kW /

1.067 m 22.371 kW /

1.067 m 29.828 kW /

1.067 m 11.2 kW / 0.914 m

18.6 kW / 1.016 m

Modul 2 - Ventilator 2 11.2 kW /

0.914 m 18.6 kW / 1.016 m

Modul 2 - Arzator 1 (kW) 1612 1978 2198 2564 3151 1319 1978

Modul 2 - Arzator 2 (kW) 1319 1978

Modul 3 - Ventilator 1

Modul 3 - Ventilator 2

Modul 3 - Arzator 1 (kW)

Modul 3 - Arzator 2 (kW)

Incarcari electrice

Trifazice / 380 V (A) 91.2 98.2 114.4 121.4 167 154.2 225.1

1 Capacitatea variaza in functie de parametri ca temperatura exterioara, umiditatea atmosferica si calitatea produsului. Valorile specificate sunt aproximative si sunt obtinute in urma unor simulari si reprezinta tone de porumb umed la intrare. In cazul uscarii fara racire, umiditatea de 15% este atinsa dupa racirea produsului in siloz.

Page 10: Uscatoarele orizontale de cereale GSI - MG Trade · Uscatoarele orizontale de cereale GSI MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter Bucuresti, Romania Fix: 021

Uscatoarele orizontale de cereale GSI

MG TRADE ENGINEERING S.R.L. Strada Miletin 56, Corp 2 Parter

Bucuresti, Romania Fix: 021 323.77.90, Fax: 021 323.26.86 [email protected], www.mgtrade.ro

Informatiile din acest document sunt cu titlu de prezentare si nu au valoare contractuala. Nu ne asumam raspunderea pentru eventualele greseli de tipar.

10/10

Seria 3000

Model 3414 3418 3420 3422 3426 3620 3626

Moduri de functionare

Flux continuu – uscare cu racire inclusa Da Da Da Da Da Da Da

Flux continuu – uscare fara racire Da Da Da Da Da Da Da

Sarja – uscare cu racire inclusa Da Da Da Da Da Da Da

Sarja – uscare fara racire Da Da Da Da Da Da Da

Capacitate uscare in flux continuu1

Uscare cu racire de la 25% la 15% (t/h) 19.25 24 25.86 28.7 34.69 26.45 35.67

Uscare cu racire de la 20% la 15% (t/h) 32.35 40.34 43.45 48.23 58.38 44.49 60.05

Uscare fara racire de la 30% la 15% (t/h) 22.04 27.09 29.61 32.93 40.23 29.52 40.17

Uscare fara racire de la 25% la 15% (t/h) 30.97 38.01 41.59 46.27 56.56 41.5 56.4

Uscare fara racire de la 20% la 15% (t/h) 52.04 63.93 69.91 77.76 95 69.77 94.76

Capacitatea si dimensiunile buncarului

Grosimea stratului de produs (cm) 35.56 35.56 35.56 35.56 35.56 35.56 35.56

Lungimea buncarului (m) 4.267 5.486 6.096 6.705 7.925 6.096 7.925

Capacitatea buncarului cu zona de preuscare (t) 27.28 35.08 38.97 42.88 50.67 38.97 50.67

Capacitatea buncarului fara zona de preuscare (t) 25.96 33.38 37.09 40.79 48.21 37.09 48.21

Incarcarea si descarcarea uscatorului

Snecul de incarcare (kW) 3.728 3.728 5.593 5.593 7.457 5.593 7.457

Capacitate (t/h) 96.52 96.52 96.52 96.52 96.52 96.52 96.52

Snecul de descarcare (kW) 3.728 3.728 5.593 5.593 7.457 5.593 7.457

Ansamblul de variatie continua a debitului

Motorul variatorului de debit (kW) 0.25 0.25 0.25 0.25 0.25 0.25 0.25

Capacitate maxima la descarcare (t/h) 49.79 64.01 71.12 78.24 92.46 71.12 92.46

Dimensiuni de gabarit

Lungime (m) 7.264 8.484 9.093 9.702 10.922 9.093 10.922

Latime (m) 2.642 2.642 2.642 2.642 2.642 2.642 2.642

Inaltime (fara suporti de fundatie) (m) 11.354 11.354 11.354 11.354 11.354 11.354 11.354

Ventilatoare si arzatoare

Modul 1 - Ventilator 1 11.185 kW /

0.711 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 1 - Ventilator 2 11.185 kW /

0.711 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 1 - Arzator 1 (kW) 1026 1319 1319 1319 1978 1319 1978

Modul 1 - Arzator 2 (kW) 1026 1319 1319 1319 1978 1319 1978

Modul 2 - Ventilator 1 11.185 kW /

1.016 m 14.914 kW /

1.067 m 18.642 kW /

1.067 m 22.371 kW /

1.067 m 29.828 kW /

1.067 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 2 - Ventilator 2 11.185 kW /

1.016 m 14.914 kW /

1.067 m 18.642 kW /

1.067 m 22.371 kW /

1.067 m 29.828 kW /

1.067 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 2 - Arzator 1 (kW) 1612 1978 2198 2564 3004 1319 1978

Modul 2 - Arzator 2 (kW) 1319 1978

Modul 3 - Ventilator 1 11.185 kW /

1.016 m 14.914 kW /

1.067 m 18.642 kW /

1.067 m 22.371 kW /

1.067 m 29.828 kW /

1.067 m 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 3 - Ventilator 2 11.185 kW /

0.914 m 18.642 kW /

1.016 m

Modul 3 - Arzator 1 (kW) 1612 1978 2198 2564 3004 1319 1978

Modul 3 - Arzator 2 (kW) 1319 1978

Incarcari electrice

Trifazice / 380 V (A) 116.2 130.2 153.4 167.4 225 211.7 372.3

1 Capacitatea variaza in functie de parametri ca temperatura exterioara, umiditatea atmosferica si calitatea produsului. Valorile specificate sunt aproximative si sunt obtinute in urma unor simulari si reprezinta tone de porumb umed la intrare. In cazul uscarii fara racire, umiditatea de 15% este atinsa dupa racirea produsului in siloz.