RTF3 Impactul DER Asupra RED
-
Upload
hairstyleady -
Category
Documents
-
view
240 -
download
1
description
Transcript of RTF3 Impactul DER Asupra RED
IMPACTUL SURSELOR REGENERABILE (SGD) ASUPRA RETELELOR ELECTRICE DE DISTRIBUTIE
RTF3-FOREN, 25.06.2014 – Bucuresti
Ioan ROSCA
Ioan DUMBRAVA
Marian GEANTA
Ioan SILVAS
Dumitru FEDERENCIUC
AGENDA
• I.IMPACTUL SURSELOR DE GENERARE DISTRIBUITA ASUPRA STANDARDULUI DE PERFORMANTA SI A REGIMURILOR DE FUNCTIONARE A RETELELOR ELECTRICE DE DISTRIBUTIE
• II.IMPACTUL SURSELOR DE GENERARE DISTRIBUITA ASUPRA NECESITATII OPERARII IN NOUL MODEL DE RETEA ELECTRICA
• III.IMPACTUL SURSELOR DE GENERARE DISTRIBUITA ASUPRA UNOR NOI MODELE DE AFACERI IN ENERGIE
I.IMPACTUL SURSELOR DE GENERARE DISTRIBUITA ASUPRA STANDARDULUI DE PERFORMANTA SI A REGIMURILOR DE
FUNCTIONARE A RETELELOR ELECTRICE DE DISTRIBUTIE
Strategia UE 20/20/20 a asigurat cadrul promovarii surselor de generare distribuita (SGD):
A)surse intermitente de energie
• Centrale electrice eoliene.
• Centrale electrice fotovoltaice (fotoelectrice).
O sursă de energie intermitentă este orice sursă de energie, care nu este disponibila în mod
continuu din cauza unor factori care sunt in afara controlului direct. Sursa intermitentă poate fi destul
de previzibila, de exemplu, energia fotovoltaica, dar nu poate fi dispecerizata pentru a satisface
cererea de putere a unui sistem .
Utilizarea eficientă a surselor intermitente într-o rețea de energie electrică se bazează de obicei pe
ideea ca aceste surse intermitente înlocuiesc combustibilul care ar fi consumat altfel prin centralele
electrice neregenerabile, sau se folosesc la stocarea energiei sub formă de apa de pompaj, de aer
comprimat sau de gheață etc pentru a fi folosit atunci când este nevoie.
B)surse operationale de energie in situatii de deficit/excedent de putere
• Centrale hidroelectrice de mică putere.
• Centrale electrice pe biogaz.
• Centrale electrice pe biomasa.
Directiva 72/CE/2009 privind regulile pietei de energie are pentru OTS si OD sprijin in Directiva 27/CE/2012
Agregarea surselor de generare distribuita cu sursele clasice si eventual cu consumatorii va fi
benefica pentru eficienta energetica a activitatii operatorului de distributie, prin realizarea
centralelor virtuale de putere (VPP) si prin raspuns la cerere (DR)
C)Gestionaraea sistemelor de stocare a energiei de catre operatorii de distributie va fi benefica
pentru toti utilizatorii retelei de distributie.
si a creat noi provocari pentru Operatorii de Distributie.
Prin promovarea SGD se trece de la un flux de putere unidirectional la un flux de putere bidirectional
Modelul NIST 2.0 de retea inteligenta
Extensia EU la modelul NIST 2.0
I1.Impactul SGD asupra calitatii energiei electrice distribuite
Prin Standardul de performanţă pentru serviciul de distributie a
energiei, aprobat prin Ordinul ANRE nr 28/2007 se stabilesc indicatorii
de performanţă privind:
(1)continuitatea alimentării cu energie electrică a clienţilor;
(2)calitatea tehnică a energiei electrice distribuite;
(3)calitatea comercială a serviciului de distribuţie a energiei electrice.
Obligatiile operatorului de distributie (OD) pentru monitorizarea calităţii
serviciului de distribuţie a energiei electrice, au la baza Ordinul ANRE
nr.28/2007 si constau in:
1 - Monitorizarea continuităţii şi calităţii energiei electrice (1) OD realizează monitorizarea acesteia într-un număr semnificativ de staţii, cu
ajutorul unor aparate complet adecvate. Aparatele de monitorizare trebuie să
permită, minimum, măsurarea, înregistrarea şi analizarea următoarelor mărimi
referitor la tensiune: întreruperile tranzitorii, întreruperile scurte şi lungi,
frecvenţa, valoarea efectivă a tensiunii, golurile de tensiune, supratensiunile
temporare la frecvenţa industrială (50 Hz) între faze şi pământ sau între faze
(voltage swells), fenomenul de flicker, variaţiile rapide şi lente de tensiune,
armonicile, interarmonicile, factorul de distorsiune armonică, nesimetria sistemului
trifazat de tensiuni. De asemenea, aparatele trebuie să permită înregistrarea şi
măsurarea curenţilor (unda fundamentală şi armonicile).
Se justifica montarea PMU in nodurile RED cu puteri peste 5MW?
(2) În anul 2008, fiecare OD titular de licenţă cu contract de concesiune a avut
obligatia de a monitoriza minimum 5 staţii în care, din informaţiile prealabile,
existau probleme. Monitorizarea valorii efective a tensiunii este necesară în
toate staţiile.
3) Suplimentar, OD trebuie să se doteze cu un număr suficient de aparate de
monitorizare portabile cu aceleaşi performanţe, pentru rezolvarea reclamaţiilor
primite de la utilizatori referitoare la calitatea energiei electrice. Costurile legate
de monitorizare revin utilizatorului, dacă parametrii sunt în limitele admisibile sau
calitatea energiei electrice este scăzută din cauza utilizatorului, respectiv OD, în
caz contrar.
• Toate aparatele de monitorizare trebuie să fie suficient de precise, cu
respectarea standardelor internaţionale de măsurare (SR EN 61000-4-30) şi
capabile să efectueze măsurători minimum conform limitelor stabilite de SR
EN 50160, pentru a putea utiliza înregistrările şi în relaţiile juridice ale OD cu
alte entităţi, ţinând cont de prevederile din contracte.
• Pentru a putea determina indicatorii de continuitate din reţea, OD vor instala
contoare de întreruperi, care să poată înregistra toate tipurile de întreruperi
(tranzitorii, scurte sau lungi). Până la 31 martie 2008, fiecare OD titular de licenţă
cu contract de concesiune trebuia sa instaleze minimum 100 de contoare de
întreruperi. Ceilalţi OD vor instala minimum 3 contoare de întreruperi.
.
SISTEMUL DISTRIBUIT DE CONTROL AL CALITATII ENERGIEI ELECTRICE
2 - Urmărirea şi înregistrarea indicatorilor de performanţă .
OD vor transmite anual la ANRE rapoarte privind performanţele realizate
referitor la calitatea energiei electrice, comparativ cu standardele impuse.
(2) Se vor prezenta datele înregistrate din staţiile monitorizate referitor la:
numărul de întreruperi tranzitorii, scurte şi lungi, golurile de tensiune, frecvenţa,
tensiunea, armonicile, factorul de distorsiune armonică, nesimetria sistemului trifazat
de tensiuni de secvenţă negativă, etc, conform tabelului 3. Dacă aparatul de
monitorizare are un soft care elaborează automat un protocol al mărimilor
înregistrate, pe o durată de minimum un trimestru, acesta se prezintă ca atare. De
asemenea, se vor prezenta detalii ale acţiunilor de remediere întreprinse în urma
acţiunilor de monitorizare. În paralel, OD vor prezenta anual ANRE rapoarte
privind reclamaţiile clienţilor referitoare la continuitatea şi calitatea energiei
electrice, modul de soluţionare şi timpul în care li s-a răspuns
AVAND IN VEDERE CA IN PCC DINTRE OD SI SGD S-AU MONTAT
ECHIPAMENTE DE MASURAREA CALITATII ENERGIEI CU POSIBILITATE DE
TRANSMITERE DE LA DISTANTA A DATELOR ESTE OPORTUNA REALIZAREA
UNEI PLATFORME CARE SA INTEGREZE TOATE SOLUTIILE DE
MONITORIZARE A CALITATII ENERGIEI?
Integrarea aparatelor de masurarea calitatii intr-o platforma PQ View
SURSA:
I2.Impactul introducerii unei SGD asupra nivelului de c.p.t.
Racordarea unei SGD (CEF de 2.5MW)
~
Staţie detransformare
Post detransformare
Sursădistribuită
PCC
IT
MT
JT
160 0.1MW
630 0.3MW
400 0.2MW
400 0.2MW
630 0.3MW 160
0.1MW
1000 0.5MW
630 0.3MW
50 OlAl 2km
3km
5km
3km 2km
3km 4km
5km
2km
1km
1km
2500 (0-2.5)MW
2.1MW
Pfec= 7 MW
2MW consum
max
PD= 1,93 MW
SPG(MW) n nec ∆P(kW) pozitia pt n
0 0,00 0,00 58,5 1
0,25 0,13 0,04 47,5 2
0,5 0,26 0,07 39,2 3
1 0,52 0,14 30,5 4
1,5 0,78 0,21 31,7 5
2 1,04 0,29 42,5 6
2,5 1,30 0,36 62,6 7 0,00
10,00
20,00
30,00
40,00
50,00
60,00
70,00
1 2 3 4 5 6 7
n
∆P(kW)
O CONFIRMARE INTERESANTA DE ANALIZAT IN MEDIE TENSIUNE VA FI CEA OFERITA DE CONTOARELE DE LA OPERATORUL DE MASURARE “ELECTRICA”…
1.Alegerea metodei de calcul al pierderilor de energie functie de gradul de penetrare a sarcinii
2.Modalitati de calcul a pierderile anuale de energie electrica in scenariul o singura SGD
Ca atare…
Impactul SGD asupra pierderilor de energie este o problema de mare interes, așa
cum arată numărul mare de studii efectuate pe această tema.Cele mai multe din aceste
studii s-au concentrat pe studierea unui caz specific (de alimentare și conectare a SGD)
sau să elaboreze o metodologie de evaluare specifica situației de pierderi atunci când un
anumit scenariu de penetrare SGD a fost stabilit. Aceasta impune o noua preocupare de
investigatie prin studii specializate asupra a ceea ce este evoluția estimată a
pierderilor într-o retea electrica de distributie, funcție de diferiti parametrii, cum ar fi : gradul de penetrare a SGD, amestecul de tehnologii a SGD, dispersia și locația SGD,
prognoza de productie sau functie de sistemul de control al energiei reactive.
Din concluziile studiilor efectuate au arătat că distribuitorul de energie electrică obţine
beneficii de pe urma penetrării generării distribuite doar în cazul în care aceasta produce
sub 23 % din electricitatea consumată în zonă, iar generatoarele SGD fiind optimal
distribuite în reţea, explicaţia fiind aceea că beneficiile apar datorită reducerii CPT .
Mentionam ca functie de gradul de penetrare a SGD si de modul de amplasare ale
acestora reteaua electrica de distributie poate fi pasiva (reteaua proiectata), poate
devini partial activa (noduri cu prosumeri) sau activa (colecteaza toate SGD).
Situația ATR și CR pentru CEE de pe site-ul Transelectrica la 16.06.2014
Situația ATR și CR pentru CEF de pe site-ul Transelectrica la 16.06.2014
ASADAR, …
IMPACTUL REAL AL S.G.D. ASUPRA NIVELULUI C.P.T. IN RED VA TREBUI SA FIE :
EVALUAT DIN TIMP, PRIN STUDII PE NIVELE DE TENSIUNI LA STADIUL ACTUAL AL PIF-urilor, CR , ATR sau SS IN CURS DE AVIZARE, IN BAZA UNEI METODOLOGII AGREATE DE ANRE, STUDII PROMOVATE PRIN GRIJA OPERATORILOR DE DISTRIBUTIE SI
VALIDAT PRIN SISTEME DE MASURARE INTELIGENTE, CARE FAC OBIECTUL ACTIUNILOR IMPUSE PRIN ORDINUL ANRE NR 91/2012.
Regandirea metodologiei de elaborare studii de prognoza a cpt
0
500
1000
1500
2000
2500
8.1
.20
13
1:0
0
8.2
.20
13
11
:00
8.3
.20
13
21
:00
8.5
.20
13
7:0
0
8.6
.20
13
17
:00
8.8
.20
13
3:0
0
8.9
.20
13
13
:00
8.1
0.2
01
3 2
3:0
0
8.1
2.2
01
3 9
:00
8.1
3.2
01
3 1
9:0
0
8.1
5.2
01
3 5
:00
8.1
6.2
01
3 1
5:0
0
8.1
8.2
01
3 1
:00
8.1
9.2
01
3 1
1:0
0
8.2
0.2
01
3 2
1:0
0
8.2
2.2
01
3 7
:00
8.2
3.2
01
3 1
7:0
0
8.2
5.2
01
3 3
:00
8.2
6.2
01
3 1
3:0
0
8.2
7.2
01
3 2
3:0
0
8.2
9.2
01
3 9
:00
8.3
0.2
01
3 1
9:0
0
9.1
.20
13
5:0
0
9.2
.20
13
15
:00
9.4
.20
13
1:0
0
9.5
.20
13
11
:00
9.6
.20
13
21
:00
9.8
.20
13
7:0
0
9.9
.20
13
17
:00
9.1
1.2
01
3 3
:00
9.1
2.2
01
3 1
3:0
0
9.1
3.2
01
3 2
3:0
0
9.1
5.2
01
3 9
:00
9.1
6.2
01
3 1
9:0
0
9.1
8.2
01
3 5
:00
9.1
9.2
01
3 1
5:0
0
9.2
1.2
01
3 1
:00
9.2
2.2
01
3 1
1:0
0
9.2
3.2
01
3 2
1:0
0
9.2
5.2
01
3 7
:00
9.2
6.2
01
3 1
7:0
0
9.2
8.2
01
3 3
:00
9.2
9.2
01
3 1
3:0
0
9.3
0.2
01
3 2
3:0
0
kWh
kWh
kVARh
kVARh
0 100 200 300 400 500
8.1
.20
13
…
8.2
.20
13
…
8.3
.20
13
…
8.5
.20
13
…
8.6
.20
13
…
8.8
.20
13
…
8.9
.20
13
…
8.1
0.2
01
…
8.1
2.2
01
…
8.1
3.2
01
…
8.1
5.2
01
…
8.1
6.2
01
…
8.1
8.2
01
…
8.1
9.2
01
…
8.2
0.2
01
…
8.2
2.2
01
…
8.2
3.2
01
…
8.2
5.2
01
…
8.2
6.2
01
…
8.2
7.2
01
…
8.2
9.2
01
…
8.3
0.2
01
…
9.1
.20
13
…
9.2
.20
13
…
9.4
.20
13
…
9.5
.20
13
…
9.6
.20
13
…
9.8
.20
13
…
9.9
.20
13
…
9.1
1.2
01
…
9.1
2.2
01
…
9.1
3.2
01
…
9.1
5.2
01
…
9.1
6.2
01
…
9.1
8.2
01
…
9.1
9.2
01
…
9.2
1.2
01
…
9.2
2.2
01
…
9.2
3.2
01
…
9.2
5.2
01
…
9.2
6.2
01
…
9.2
8.2
01
…
9.2
9.2
01
…
9.3
0.2
01
…
kWh
kWh
kVARh
kVARh
CEE
CEF
0,00
500,00
1000,00
1500,00
2000,00
2500,00
3000,00 9
.8.1
3 1
:00
PM
10
.8.1
3 5
:00
PM
11
.8.1
3 9
:00
PM
13
.8.1
3 1
:00
AM
14
.8.1
3 5
:00
AM
15
.8.1
3 9
:00
AM
16
.8.1
3 1
:00
PM
17
.8.1
3 5
:00
PM
18
.8.1
3 9
:00
PM
20
.8.1
3 1
:00
AM
21
.8.1
3 5
:00
AM
22
.8.1
3 9
:00
AM
23
.8.1
3 1
:00
PM
24
.8.1
3 5
:00
PM
25
.8.1
3 9
:00
PM
27
.8.1
3 1
:00
AM
28
.8.1
3 5
:00
AM
29
.8.1
3 9
:00
AM
30
.8.1
3 1
:00
PM
31
.8.1
3 5
:00
PM
1.9
.13
9:0
0 P
M
3.9
.13
1:0
0 A
M
4.9
.13
5:0
0 A
M
5.9
.13
9:0
0 A
M
6.9
.13
1:0
0 P
M
7.9
.13
5:0
0 P
M
8.9
.13
9:0
0 P
M
10
.9.1
3 1
:00
AM
11
.9.1
3 5
:00
AM
12
.9.1
3 9
:00
AM
13
.9.1
3 1
:00
PM
14
.9.1
3 5
:00
PM
15
.9.1
3 9
:00
PM
17
.9.1
3 1
:00
AM
18
.9.1
3 5
:00
AM
19
.9.1
3 9
:00
AM
20
.9.1
3 1
:00
PM
21
.9.1
3 5
:00
PM
22
.9.1
3 9
:00
PM
24
.9.1
3 1
:00
AM
25
.9.1
3 5
:00
AM
26
.9.1
3 9
:00
AM
27
.9.1
3 1
:00
PM
28
.9.1
3 5
:00
PM
29
.9.1
3 9
:00
PM
kWh
kWh
kVArh
kVArh
SGD=CEE+CEF
333kW CONSUM
II.IMPACTUL SURSELOR DE GENERARE DISTRIBUITA ASUPRA NECESITATII OPERARII
IN NOUL MODEL DE RETEA ELECTRICA
SURSA :CEN CENELEC SI ETSI
Se impune o noua arhitectura de RED
Conform CEN-CENELEC-ETSI principalele sisteme ale rețelelor inteligente din distributie, sunt: 1.Sistemul de management al distributiei cu -Sistemul de automatizare al statiilor de transformare SCADA -Automatizarea fiderilor /SAD-U/axelor /SAD :reclosere,STC -Sistemul distribuit de control al calitatii energiei electrice -Sistemul SCADA-DMS integrat in Sistemul GIS
-FACTS-Sisteme flexibile de transport in c.a.(Bobine,Capacitati) 2.Sistemul de operare a generarii distribuite(DER) cu
-Sistemul de operare a generarii distribuite
-Sistemul EMS-SCADA al generarii distribuite si Sistemul de centrale virtuale (VPP)
3.Sistemul de contorizare inteligenta cu -Sistemul de infrastructuri avansate de contotizare inteligenta (AMI) -Sistemele back-office ale contorizarii (MDM, SAP I-SU)
4.Sistemele de flexibilizare a cererii si a productiei (DR) cu -Sistemul de management al agregarii prosumerilor si HVDC -Sistemele de stocare a energiei electrice
5.Conectarea la reteaua electrica a vehiculelor electrice (e-mobility) cu -Sistemele de incarcare e-mobility
6.Sistemul de piata a energiei electrice cu -Sistemul de piata (concurentiala, reglementate) -Sistemele de trading (PCCB,PZU,PIZ,PE)
7.Sistemele de administrare cu -Sistemul de management al activelor si al mentenantei (Asset Management) -Sistemele de management al infrastructurilor de comunicatii -Sistemul de configurare de la distanta a dispozitivelor RTU si a contoarelor inteligente -Sistemul de autentificare si autorizare de la distanta a conturilor -Sistemul de referinta a ceasului (GPS etc) -Sistemul de monitorizare meteo si prognoza
SCADA in
statia de
transformare
SAD,
(reclosere ,STC)
SAD-U
(RTU in PT/PA)
FACTS
SCADA-DMS
si GIS la OD
Sistem de
control PQ
distribuit
AUTOMATIZAREA ACTIVITATII DE DISTRIBUTIE ESTE IMPUSA DE STANDARDUL DE PERFORMANTA
Integrarea si monitorizarea RES/DER
DER EMS si sistemul VPP Sistemul de operare DER
ACTIVITATE CE TREBUIE SA FIE ORGANIZATA LA NIVELUL OD DUPA APARITIA CODURILOR CE SUNT IN ELABORARE LA ENTSO-E
Se poate mapa “Controlul puterii reactive al unei unitati DER”
PQ View
Sisteme de operare MS Windows Linux Iphone Android etc
PQ View PQ Data Manager
PQ View PQ Data Manager
PQ View PQ Data Manager
Integrarea Power Quality Platform – cu alte platforme
Equ
ipm
en
te p
ort
abile
PQ
Eq
uip
me
nte
PQ
in m
on
taj f
ix
SCADA-DMS
MDM Smart Metering
SCADA-EMS DER/RES
ACTIUNEA DE IMPLEMENTARE A CONTORIZARII INTELIGENTE A FOST APROBATA PRIN LEGEA 123/2012 ART 66 SI ESTE MONITORIZATA DE ANRE
III.IMPACTUL SURSELOR DE GENERARE DISTRIBUITA ASUPRA UNOR NOI MODELE DE AFACERI IN ENERGIE
• Operatorul sistemului de distribuție (DSO): în conformitate cu articolul 2.6 din Directiva 2009/72/CE: "o persoană fizică sau juridică responsabilă de exploatarea, întreținerea și, dacă este necesar, dezvoltarea sistemului de distribuție într-o anumită zonă și, după caz, a interconexiunilor acestuia cu alte sisteme, precum și pentru asigurarea pe termen lung a capacității sistemului de a satisface cererile rezonabile de distribuție a energiei electrice ".
• Mai mult decât atât, DSO este responsabil pentru acces la rețeaua regională, stabilitatea rețelei, integrarea surselor regenerabile de energie la nivelul distribuției și echilibrarea sarcinilor la nivel local.
www.pwc.com/utilities
Studiul: Transformarea energiei - Impactul pe
modelul de afaceri in sectorul energetic
94% prevad transformare completa sau schimbari importante in
modelul de afaceri a utilitatii de energie
67% se asteapta la tehnologii si noi surse de energie ce vor reduce
dramatic dependenta de petrol si gaz din tarile bogate
82% vad generarea de energie distribuita ca o “oportunitate” fata de
numai 18% care o vad ca o “amenintare ”
Pentru indicatorii de calitate a electricitatii sunt prevederi clare in Standardul de performanta Pentru calcul cpt exista Metodologiile CIRE pentru elaborare studiilor de determinare a c.p.t. tehnic pe categorii de instalatii in vederea alocarii cifrelor de monitorizare realizate pentru RED cu noduri pasive.
Modelul de afaceri al unui OD stabilit de catre ANRE prin Metodologia tarifului de distributie:
Aparitia surselor de generare distribuita (SGD) are urmatoarele influente in modelul de afaceri:
OD
Ce servicii auxiliare poate oferi un operator de distributie ? /1
(* sursa Eurelectric)
Pentru a răspunde la această întrebare s-a început prin identificarea posibilelor modele
viitoare ale pieței și oportunități de afaceri pentru rețelele inteligente. Bazat pe literatura de
specialitate și interviuri cu mai mult de 30 de părți interesate, au fost identificate următoarele
cinci servicii de retea inteligenta
1 . Servicii de flexibilitate
Serviciile de flexibilitate sunt legate de capacitatea de adaptare și anticipare la condiții
incerte și schimbatoare ale sistemului de putere, într-un mod rapid, sigur și rentabil. Se
poate distinge între furnizare și cererea de servicii de flexibilitate.
Flexibilitatea pot fi oferita de către utilizatorii sistemului de exemplu producători, consumatori
sau prosumers (prin răspuns la cerere, generare distribuită, stocare) sau prin intermediari,
cum ar fi agregatorii și furnizori în numele celor dintâi.
Pe partea de cerere, operatorii de rețele, atât TSO și DSO, pot folosi flexibilitatea pentru
gestionarea congestiei ca un substitut pentru investiții în infrastructură. Odată cu creșterea
producției de generare distribuită, care de multe ori nu este dispecerizabila din cauza naturii
sale intermitente, fluxurile de rețea devin mai variabile și nu pot fi rezolvate eficient în faza
de planificare a rețelei crescand nevoile de investiții în rețea.
Mai mult decât atât, cererea de flexibilitate provine, de asemenea, de la agregatori, furnizorii
en detail, furnizorii angro, PRE-partile responsabile cu echilibrarea și TSO în scopuri de
echilibrare.
2. Furnizarea infrastructurii pentru încărcare vehicule electrice
Extinderea utilizării vehiculelor electrice necesită o disponibilitate suficienta de
puncte de încărcare a vehiculelor electrice pentru a deveni atractiva.
Infrastructura de incarcare, diferă de asemenea, prin viteza de încărcare, fie
normala fie încărcare rapidă, sau dacă încărcarea se face fie într-un mod
necontrolat, fie într-un mod inteligent controlat. Acesta din urmă are implicații
pentru gradul de flexibilitate pe care EV pot fi în măsură să ofere. În caz
de încărcare necontrolata , intr-o maniera gresita , oportunitățile de flexibilitate,
cum ar fi stocarea sau descărcarea nu pot fi ușor instalate, în timp ce în cazul
încărcarii inteligente flexibilitatea poate fi valorificata. Mai mulți actori ar putea
juca un rol în furnizarea infrastructurii de încărcare a EV, cum ar fi DSO sau
furnizori care pot folosi punctele de încărcare sa vinda energie electrică. Alți
actori comerciali, pot furniza, de asemenea, acces la infrastructura EV, cum ar fi
investitorii privați și furnizori de e-mobilitaty independenti, care ar putea furniza
energie electrică la pachet cu alte servicii.
Ce servicii auxiliare poate oferi un operator de distributie ? /2
(* sursa Eurelectric)
Ce servicii auxiliare poate oferi un operator de distributie ? /3
(* sursa Eurelectric) 3. Servicii de eficiență energetică Serviciile de eficiență energetică cuprind toate serviciile destinate realizării eficienței energetice la nivelul utilizatorului final. Rețelele inteligente în combinație cu contorizările inteligente pot furniza informații detaliate cu privire la utilizarea, în scopul de a (i) informa consumatorii; (ii) pentru a-i ajuta la identificarea opțiunilor eficiente din punct de vedere a costului, pentru economisirea de energie și ar putea crea noi oportunități de afaceri pentru investiții în economisirea de energie. Un număr de diferiți actori pot oferi servicii de eficiență energetică, cum ar fi DSO, furnizorii de energie electrică, precum și firme independente, cum ar fi companiile ESCO. 4. Dreptul de proprietate și gestionare a echipamentelor de contorizare În scopul de implicare a consumatorilor în promovarea Retelelor Inteligente la nivel de joasă tensiune, contoarele inteligente pot acționa ca un factor important. Contoarele inteligente oferă mai multe informații precise pentru clienți mici, cu privire la consumul lor de energie. În plus, ele permit trecerea mai ușoară de la un furnizor la altul -în acțiunea de schimbare a furnizorului, economii de costuri în operarea contorului din cauza citirii de la distanță, precum și economii de costuri cu functionarea call center-ului. Mai mult decât atât, contoarele inteligente faciliteaza oportunități de răspuns la cerere (DR) și oferă potențial de generare a flexibilitatii din spatele contorului (prin VPP). 5. Manipularea datelor Noi sarcini și servicii într-un mediu de rețea inteligentă depind de disponibilitatea datelor furnizate de echipamentele de măsurare, atât în reteaua in sine cat si la sediul clientului. Datele pot fi utilizate de actorii comerciali, de exemplu pentru realizarea de economii de energie ca răspuns la cerere, precum și de operatorii rețea, atât pentru sistemul de management pe termen scurt, precum și pentru planificarea rețelei pe termen lung.
CONCLUZII: SGD pot aduce potentiale beneficii asupra retelelor de distributie : -tind sa creasca nivelul de securitate al retelei -la un nivel de penetrare <23% cpt este diminuat -reglajul tensiunii se poate optimiza , dar cu costuri suplimentare etc, etc , SGD pot imbunatati sau inrautati calitatea serviciilor oferite catre clienti ? Gestionarea utilizatorilor RED poate fi uneori prea costisitoare, de aceea se impune revederea modelului de afaceri si adaptarea lui la competitivitate si transparenta avand in vederea evolutia in ultimii ani a infrastructurilor de comunicatii, a celei de incalzire centralizata etc